4 of 18
An Alliance Technology Company
600 Dekora Woods Blvd. Saukville, WI 53080
Toll Free: 800-488-8177 Local: 262-268-9330 Fax: 262-268-9952
An Alliance Technology Company
SYSTEM MAINTENANCE REQUIREMENTS
The following maintenance procedures are recommended for all Insight-Vision Xpress
systems. Standard warranty policy dictates that components and accessories subject to wear
and tear are not covered under the One (1) year warranty. Therefore we are strongly
recommending that all systems be maintained according to the following procedures. Please
be advised that Insight-Vision will not allow warranty coverage for these items if these
procedures are not followed.
DVDXpress Command Module Recorder: Due to the adverse conditions that the DVDX
experiences during use, Insight Vision strongly recommends that the cleaning procedure
described below be performed for every 5 or 6 hours of use.
WARRANTY REPAIRS WILL NOT BE GRANTED FOR DAMAGE CAUSED BY
DIRTY DVD PLAYERS AS THIS IS A RESULT OF USE AND NOT
MANUFACTURERS DEFECTS.
Cleaning Procedure: Insert a DVD Laser Lens Cleaner disc into the DVDX Command
Module and run the cleaning process once or twice to clean the recorder.
Please note that the DVD disc that was originally experiencing problems may have
permanent errors as a result of the dirty recorder. Starting a new disc may be necessary.
These cleaning DVDs are available at Wal-Mart for $6 - $7. Phillips, Memorex, and Maxell
are some of the brands that Insight Vision recommends.
O-Rings: O-rings are critical to insure watertight integrity of the camera and connection
areas. O-rings are subject to wear and tear and can also suffer failure due to age and other
factors. They should be inspected regularly and replaced whenever needed.
When O-rings are working properly, a small amount of water and sometimes fine particles of
grit will build up behind them. Any time the camera or sonde connection is taken apart and
exposed, there exists the risk of grit wearing down or possibly even tearing the o-ring. It is
also possible for water to then enter the slip-ring area once exposed. All connections, once
opened or exposed, MUST be thoroughly cleaned and dried before re-connecting. We
recommend using an old toothbrush or other soft bristled brush to clean the o-ring areas and
remove the grit or fine debris. Then, dry the area around the o-ring and pogo pins and slip
area completely before re-connecting.