![Inside Out Networks Digi Edgeport/1i Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/inside-out-networks/digi-edgeport-1i/digi-edgeport-1i_installation-manual_2065409016.webp)
Edgeport Industrial Installation Guide (90000409 Rev. C) – Page 14
Remap Baud
: (All operating systems - 930 and TI based Edgeport)
Setting the baud rate to 1200 baud will result in 230400 baud
Ignore Flush
: (Windows NT/2K/XP 930 and TI)
If an application sends IRP_MJ_FLUSH_BUFFERS it will be ignored.
Excerpt from Microsoft documentation:
Drivers of devices with internal caches for data and drivers that maintain internal buffers for data
must handle this request.
When Sent
Receipt of a flush request indicates that the driver should flush the device's cache or its internal
buffer, or, possibly, should discard the data in its internal buffer.
Operation
The driver transfers any data currently cached in the device or held in the driver's internal
buffer(s) before completing the flush request. The driver of an input-only device that buffers data
internally might simply discard the currently buffered device data before completing the flush IRP,
depending on the nature of its device.
Fast Reads:
This flag is used when an application requires that a read complete immediately. In the read
immediate case, the Edgeport driver will send a request to the Edgeport device asking for any
buffered data to be sent up. This buffered data will be included when the read completes. If this
flag is set, the driver will not query the Edgeport device for additional data.
Fast Writes
: (All operating systems - 930 and TI based Edgeport)
When an application sends a write to the driver, by default the Edgeport driver will wait until all
data has been transmitted out of the Edgeport device before completing the write. When the Fast
Writes flag is set, we complete the write even if data is still buffered in the driver and the Edgeport
device.
Ignore Tx Purge:
The IOCTL_SERIAL_PURGE request cancels the specified requests and deletes data from the
specified buffers. The purge request can be used to cancel all read requests and write requests
and to delete all data from the read buffer and the write buffer.
When the
Ignore Tx Purge
flag is set the SERIAL_PURGE_TXCLEAR command will be ignored.
The function will not purge the write buffer.
Disable Plug & Play
: (Windows 2k/XP only)
Do not let the serial port enumerator detect devices plugged into the Edgeport.
Timer Logic
: (Windows 9x only)
If application uses PortSetReadCallBack(), the notification routine will only be called when the
number of bytes in the receive buffer is greater then the RX trigger. The Microsoft serial VxD also
implements a timer that will trigger and call the notification routine if some amount of data is
available in the RX buffer but no new data has been received for ~200ms (receiver is no longer
active).
We do not enable this behavior by default because of the nature of Edgeport buffering. But if you
set the flag we will complete the read when we detect ~200 ms no activity.
Here is a comment from the code: