Edgeport Industrial Installation Guide (90000409 Rev. C) – Page 14 

Remap Baud

: (All operating systems - 930 and TI based Edgeport) 

Setting the baud rate to 1200 baud will result in 230400 baud 

Ignore Flush

: (Windows NT/2K/XP 930 and TI) 

If an application sends IRP_MJ_FLUSH_BUFFERS it will be ignored. 

Excerpt from Microsoft documentation:  

Drivers of devices with internal caches for data and drivers that maintain internal buffers for data 
must handle this request. 

When Sent 

Receipt of a flush request indicates that the driver should flush the device's cache or its internal 
buffer, or, possibly, should discard the data in its internal buffer. 

Operation 

The driver transfers any data currently cached in the device or held in the driver's internal 
buffer(s) before completing the flush request. The driver of an input-only device that buffers data 
internally might simply discard the currently buffered device data before completing the flush IRP, 
depending on the nature of its device. 

Fast Reads: 

This flag is used when an application requires that a read complete immediately. In the read 
immediate case, the Edgeport driver will send a request to the Edgeport device asking for any 
buffered data to be sent up.  This buffered data will be included when the read completes.  If this 
flag is set, the driver will not query the Edgeport device for additional data. 

Fast Writes

: (All operating systems - 930 and TI based Edgeport) 

When an application sends a write to the driver, by default the Edgeport driver will wait until all 
data has been transmitted out of the Edgeport device before completing the write. When the Fast 
Writes flag is set, we complete the write even if data is still buffered in the driver and the Edgeport 
device. 

Ignore Tx Purge: 

The IOCTL_SERIAL_PURGE request cancels the specified requests and deletes data from the 
specified buffers. The purge request can be used to cancel all read requests and write requests 
and to delete all data from the read buffer and the write buffer. 

When the 

Ignore Tx Purge

 flag is set the SERIAL_PURGE_TXCLEAR command will be ignored. 

The function will not purge the write buffer. 

Disable Plug & Play

: (Windows 2k/XP only) 

Do not let the serial port enumerator detect devices plugged into the Edgeport. 

Timer Logic

: (Windows 9x only) 

If application uses PortSetReadCallBack(), the notification routine will only be called when the 
number of bytes in the receive buffer is greater then the RX trigger.  The Microsoft serial VxD also 
implements a timer that will trigger and call the notification routine if some amount of data  is 
available in the RX buffer but no new data has been received for ~200ms (receiver is no longer 
active).   

We do not enable this behavior by default because of the nature of Edgeport buffering. But if you 
set the flag we will complete the read when we detect ~200 ms no activity. 

Here is a comment from the code: 

Содержание Digi Edgeport/1i

Страница 1: ...Edgeport U S B EX P A N S I O N MO D U L E S I N D U S T R I A L Installation Guide www ionetworks com ...

Страница 2: ...dgeport 1i 1 Edgeport 2i 2 Edgeport 4i Edgeport 8i 3 Edgeport 2 2i 5 Edgeport 4s MEI Edgeport 8s MEI 6 Edgeport Driver Installation 8 Mounting Diagrams 11 The Edgeport Utility Program 12 Understanding Hubs 17 Regulatory Other Information 18 ...

Страница 3: ... Edgeport 1i you will short or leave unconnected certain pins at the DB9 connector of the cable See the following pin assignment 3 g TA T transmit data negative 7 g TB T transmit data positive 8 g RA R receive data negative 4 g RB R receive data positive 5 g signal ground 2 g no connect For jumper wire based mode configuration use the following pins 1 g full and half duplex 6 g echo on and off 9 g...

Страница 4: ...ilable USB port on a standard hub or into an Inside Out Networks Hubport Plug the Type B square end of the USB cable into the Edgeport RS422 485 Serial Connection Cable Connections DB9 Female for Full Duplex 3 g TA T transmit data negative 7 g TB T transmit data positive 8 g RA R receive data negative 4 g RB R receive data positive 5 g signal ground 1 2 6 9 no connect NOTE For full duplex in the a...

Страница 5: ...o the documentation section of our web site at www ionetworks com support After configuration you may proceed to Edgeport Driver Installation on page 8 If the drivers are not already installed go to Edgeport Driver Installation starting on page 8 Figure 2 Eight Position DIP Switch 1 2 3 4 5 6 7 8 h ON i OFF 1 echo disabled 1 echo enabled 2 half duplex 2 full duplex 3 terminating 3 no terminating r...

Страница 6: ...t Networks Hubport Plug the Type B square end of the USB cable into the Edgeport Cable Connections DB9 Female for Full Duplex 3 g TA T transmit data negative 7 g TB T transmit data positive 8 g RA R receive data negative 4 g RB R receive data positive 5 g signal ground 1 2 6 9 no connect NOTE For full duplex in the above diagram the differential pair TA and TB should be together in one twisted pai...

Страница 7: ...USB port on a standard hub or into an Inside Out Networks Hubport Plug the Type B square end of the USB cable into the Edgeport Cable Connections DB9 Female for Full Duplex 3 g TA T transmit data negative 7 g TB T transmit data positive 8 g RA R receive data negative 4 g RB R receive data positive 5 g signal ground 1 2 6 9 no connect NOTE For full duplex in the above diagram the differential pair ...

Страница 8: ...rks Hubport Plug the Type B square end of the USB cable into the Edgeport Cable Connections DB9 Female for Full Duplex 3 g TA T transmit data negative 7 g TB T transmit data positive 8 g RA R receive data negative 4 g RB R receive data positive 5 g signal ground 1 2 6 9 no connect NOTE For full duplex in the above diagram the differential pair TA and TB should be together in one twisted pair and R...

Страница 9: ...d click on the Port Flag Configuration button The drop down boxes under the Industrial Settings allows you to select from the following options for each port listed RS232 RS422 No Terminating Resistor RS422 Terminating Resistor RS485 Half Duplex End Unit Echo RS485 Half Duplex End Unit No Echo RS485 Half Duplex Middle Unit Echo RS485 Half Duplex Middle Unit No Echo RS485 Full Duplex End Unit Maste...

Страница 10: ...ave received Designed for Windows 2000 certification Drivers downloaded from our web site may be pending certification If so Windows 2000 will display a warning Digital Signature Not Found Click Yes to continue with driver installation If you click No you will need to contact Inside Out Networks Technical Support 512 306 0600 before installing your USB Plus Series product 8 Windows will then finis...

Страница 11: ...t the installation or to continue and be required to reboot before the upgrade can take effect Note that because Windows NT 4 0 is not Plug and Play you will not see a pop up dialog box indicating that new hardware has been found You may verify correct installation with the Edgeport Utility see page 12 or the USB Status Utility Viewer as described below The USB Status Utility can be accessed by cl...

Страница 12: ...cted the light will blink red a few moments before turning green Otherwise the light indicates a problem with the drivers which may need to be reinstalled The red light will also blink during installation until the installation is complete Amber This light signifies serial port activity on the Edgeport The amber light may also flash briefly during installation Green This light indicates the serial...

Страница 13: ...dgeport Industrial Installation Guide 90000409 Rev C Page 11 Mounting Diagrams For all Edgeports except the Edgeport 1i Rack Mount Kit Under Shelf Mounting Bracket Nuts bolts and screws are not included ...

Страница 14: ... exe allows you to manage the serial ports of your Edgeport product Note that with Windows NT you must have administrative privileges in order to change the COM port settings For more information see the Support section at www ionetworks com The General tab in this utility allows you to do the following Information Check the manufacturing information pertaining to your device ...

Страница 15: ...ecial functionality on a per port basis Industrial Settings For the Edgeport 4s MEI and Edgeport 8s MEI only see Port Flags on page 6 Low Latency 930 based Edgeport only Normally the UART will interrupt when the receiver has been idle for 4 character times For example 4ms at 9600 As long as data is being received the UART will continue to buffer them until its internal FIFO is full 56 bytes This f...

Страница 16: ...e for additional data Fast Writes All operating systems 930 and TI based Edgeport When an application sends a write to the driver by default the Edgeport driver will wait until all data has been transmitted out of the Edgeport device before completing the write When the Fast Writes flag is set we complete the write even if data is still buffered in the driver and the Edgeport device Ignore Tx Purg...

Страница 17: ... this read The problem is that the Edgeport buffers the RX bytes and we poll the driver If we do not receive any bytes in 200ms we may report an erroneous event even if there are available bytes in the Edgeport device or driver Test Ports Perform a confidence test on the internal workings of the serial ports ...

Страница 18: ...number No matter which physical USB port a converter is plugged into it will maintain its assigned COM port numbers 2 Assign COM ports based on physical USB port In this mode the driver identifies a converter based on the physical USB port it is plugged into This effectively assigns COM port numbers to physical USB ports No matter which converter is plugged into a given USB port it will use the CO...

Страница 19: ... system which then enables and disables the device as a function of its power requirements and the amount of available power High powered devices typically need to be connected to a self powered hub such as the Hubport which obtains power from its external power supply and provides up to 500 mA for each downstream port Only low powered devices such as a mouse can be connected to a bus powered hub ...

Страница 20: ...ense They may be used disclosed and or copied only as supplied under such license agreement Any copy must contain the above copyright notice and restricted rights notice Use copying and or disclosure of the programs is strictly prohibited unless otherwise provided for in the license agreement Federal Communications Commission FCC Regulatory Information USA only This equipment has been tested and f...

Страница 21: ...EU Directives listed here EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC Amending Directive 93 68 EEC using the relevant section of the following EU standards and other normative documents Safety IEC 950 1991 A1 A2 A3 A4 EN 60950 1992 A1 A2 A3 A4 EMC The following summarizes the specifications and requirements for EN55024 EN55022 Class B CISPR 22 Class B emission and immunity tests If th...

Страница 22: ...Inside Out Networks A Digi International Company 7004 Bee Caves Road Building 3 Suite 200 Austin TX 78746 512 306 0600 ph 512 306 0694 fax www ionetworks com info ionetworks com Digi Europe 49 231 9747 0 Digi Hong Kong 852 2833 1008 Digi North America 877 912 3444 ...

Отзывы: