Inscape Data LinkPower LPS1800 Series Скачать руководство пользователя страница 3

 

Page 

3

 

Revision 1.0 

Limited Warranty and Disclaimer of Warranty

 

Hardware. 

Inscape Data Corporation, or subsidiary selling the Product (“Inscape Data”) warrants that 

commencing from the date of shipment to Customer (and in case of resale by a Inscape Data’s reseller, 

commencing not more than ninety (90) days after original shipment by Inscape Data), and continuing 

for  a  period  of  the  longer  of  (a)  ninety  (90)  days  or  (b)  the  period  set  forth  in  the  warranty  card 

accompanying  the  Product  (if  any),  the  Hardware  will  be  free  from  defects  in  material  and 

workmanship under normal use.    The date of shipment of a Product by Inscape Data is set forth on the 

packaging material in which the Product is shipped. This limited warranty extends only to the original 
user of the Product. Customer’s sole and exclusive remedy and the entire liability of Inscape Data and 

its  suppliers  under  this  limited  warranty  will  be,  at  Inscape  Data’s  or  its  service  center’s  option, 

shipment  of  a  replacement  within  the  warranty  period  and  according  to  the  replacement  process 

described in the warranty card (if any), or if no warranty card, as described on the Inscape Data Product 

Warranty Policy or a refund of the purchase price if the Hardware is returned to the party supplying it 

to  Customer,  freight  and  insurance  prepaid.  Inscape  Data  replacement  parts  used  in  Hardware 

replacement  may  be  new  or  equivalent  to  new.  Inscape  Data’s  obligations  hereunder  are  conditioned 
upon  the  return  of  affected  Hardware  in  accordance  with  Inscape  Data’s  or  its  service  center’s 

then-current Return Material Authorization (RMA) procedures.     

Software. 

The limited warranty in the United States Federal Communications Commission Notice sets 

forth Inscape Data’s warranty obligations with respect to the Software.   

Restrictions. 

The above Hardware warranty and limited warranty in the End User License Agreement 

(“Software  warranty”)  do  not  apply  if  the  Software,  Hardware Product  or  any  other  equipment  upon 

which the Software is authorized by Inscape Data or its suppliers or licensors to be used (a) has been 

altered,  except  by  Inscape  Data  or  its  authorized  representative,  (b)  has  not  been  installed,  operated, 

repaired,  or  maintained  in  accordance  with  instructions  supplied  by  Inscape  Data,  (c)  has  been 

subjected  to  abnormal  physical  or  electrical  stress,  abnormal  environmental  conditions,  misuse, 

negligence, or accident; or (d) is licensed for beta, evaluation, testing or demonstration purposes. The 

Software  warranty  also  does  not  apply  to  (e)  any  temporary  Software  modules;  (f)  any  Software  not 
posted  on  Inscape Data’s Software  Center  (on  InscapeData.com  URL  where  Inscape Data  makes  the 

Software publicly available to customers); (g) any Software that Inscape Data expressly provides on an 
“AS IS” basis on Inscape Data’s Software Center; or (h) any Software for which Inscape Data does not 

receive a license fee. 

Содержание LinkPower LPS1800 Series

Страница 1: ...S1800 Series IP Management User s Manual May 2015 Corporate Headquarters Inscape Data Corporation 1620 Oakland Road D101 San Jose CA 95131 U S A Website http www inscapedata com Main 408 392 9800 Fax...

Страница 2: ...ely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user is cautioned that changes and modifications made to the equipment with...

Страница 3: ...s used in Hardware replacement may be new or equivalent to new Inscape Data s obligations hereunder are conditioned upon the return of affected Hardware in accordance with Inscape Data s or its servic...

Страница 4: ...XCLUDED TO THE EXTENT ALLOWED BY APPLICABLE LAW AND ARE EXPRESSLY DISCLAIMED BY INSCAPE DATA ITS SUPPLIERS AND LICENSORS TO THE EXTENT AN IMPLIED WARRANTY CANNOT BE EXCLUDED SUCH WARRANTY IS LIMITED I...

Страница 5: ...e Warranty One 1 Year Replacement Repair or Refund Procedure for Hardware Inscape Data or its authorized service center will use commercially reasonable efforts to ship a replacement part after receip...

Страница 6: ...MENTAL LICENSE AGREEMENT THE SUPPLEMENTAL LICENSE AGREEMENT SHALL APPLY BY DOWNLOADING INSTALLING OR USING THE SOFTWARE YOU ARE BINDING YOURSELF AND THE BUSINESS ENTITY THAT YOU REPRESENT COLLECTIVELY...

Страница 7: ...ROM or on line In order to use the Software Customer may be required to input a registration number or product authorization key and register Customer s copy of the Software online at Inscape Data s...

Страница 8: ...expressly permitted under applicable law notwithstanding this restriction iv publish any results of benchmark tests run on the Software v use or permit the Software to be used to perform services for...

Страница 9: ...written permission of Inscape Data Term and Termination The Agreement and the license granted herein shall remain effective until terminated Customer may terminate the Agreement and the license at an...

Страница 10: ...ause to the contrary in any agreement into which the Agreement may be incorporated Customer may provide to Government end user or if the Agreement is direct Government end user will acquire the Softwa...

Страница 11: ...arranty does not apply if the Software Product or any other equipment upon which the Software is authorized to be used a has been altered except by Inscape Data or its authorized representative b has...

Страница 12: ...R SUCH OTHER PRODUCT THIS LIMITATION OF LIABILITY FOR SOFTWARE IS CUMULATIVE AND NOT PER INCIDENT I E THE EXISTENCE OF TWO OR MORE CLAIMS WILL NOT ENLARGE THIS LIMIT IF YOU ACQUIRED THE SOFTWARE IN EU...

Страница 13: ...E ABOVE LIMITATION MAY NOT APPLY TO YOU IF YOU ACQUIRED THE SOFTWARE IN JAPAN EXCEPT FOR LIABILITY ARISING OUT OF OR IN CONNECTION WITH DEATH OR PERSONAL INJURY FRAUDULENT MISREPRESENTATION AND REGARD...

Страница 14: ...liability set forth herein that the same reflect an allocation of risk between the parties including the risk that a contract remedy may fail of its essential purpose and cause consequential loss and...

Страница 15: ...l law the Agreement and Warranties are controlled by and construed under the laws of the State of California United States of America notwithstanding any conflicts of law provisions and the state and...

Страница 16: ...t To minimize shock hazard the instrument chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power ca...

Страница 17: ...that services the device switch the circuit breaker to the OFF position and tape the switch handle of the circuit breaker in the OFF position Work During Lightning Activity Do not work on the system...

Страница 18: ...4 2 4 Load Default Setting 25 2 5 Firmware Update Upgrade 26 2 6 Reboot Device 27 Chapter 3 Port Setting 29 3 1 Port Configuration 29 3 2 Port Mirroring 30 3 3 Bandwidth Control 31 3 4 Broadcast Storm...

Страница 19: ...ion 47 10 1 DHCP Relay Agent Setting 47 10 2 Relay Server Setting 47 10 3 VLAN MAP Relay Agent Setting 47 Chapter 11 Configuration Backup Recovery 49 11 1 Configuration Backup Recovery 49 Chapter 12 M...

Страница 20: ...Settings VLAN QoS Settings and so on various system configurations Reader objects This manual requires a certain network knowledge from the user such as understanding of a network device and be famili...

Страница 21: ...this device support WEB management equipment IP management by default 192 168 2 1 subnet mask 255 255 255 0 the default gateway 192 168 2 254 The administrator of the PC as long as you can communicate...

Страница 22: ...n main page Note Default login ID admin and login password system Corresponding user name and password can be modified in the password setting After successfully login the main page is displayed as be...

Страница 23: ...n in the directory Administrator of the switch management on the left side go to the following page This page is used to modify the current login user name and password Click Update configuration If y...

Страница 24: ...re the IP Address Subnet Mask Gateway and IP Configure of the switch IP address configuration can t be all zeros all F and multicast address Click Update configuration after the success of the configu...

Страница 25: ...ge 2 4 Load Default Setting Restore the default value of the switch configuration back to the initial state but does not include the IP address of the device the user name and password Click Load Defa...

Страница 26: ...and confirm the same as the user password click Update to enter the flash erase page after the flash erase will pop up the following page Click on the browse select the upgrade file that you need in t...

Страница 27: ...put file path filename Bin press the return key As shown in figure Please log in again after the completion of systems Note The default update password is 123456 If return an error or the time for up...

Страница 28: ...Page 28 Revision 1 0 Click Confirm...

Страница 29: ...Auto Negotiation speed rate Speed Duplex mode Duplex flow control 802 3 x backpressure and port learning Addr Learning function In the Select Port No Port check the configuration on the function of th...

Страница 30: ...g port used to analyze and monitor packets As shown below the destination port Dest Port select the mirror port in Source Port Source Port is selected to be mirrored port Prison probe type Monitored P...

Страница 31: ...follows Low 32Kbps and High 512Kbps The formula maximum transmit receive rate Rate control 0 255 x 32 kbps low bandwidth Rate control 0 255 x 512 kbps high bandwidth Click Submit Update is configured...

Страница 32: ...bandwidth control rate the system will be connected rate as bandwidth control rate 3 4 Broadcast Storm Control As shown in Port Enable Enable Port the selected configuration port it says the maximum...

Страница 33: ...Page 33 Revision 1 0...

Страница 34: ...Port based VLAN and Tag Base VLAN The default mode is the Port based VLAN mode The following figure Click Change VLAN Mode can be switched systems VLAN mode In the Tag Base VLAN mode page the user can...

Страница 35: ...tion to end is a PC card generally it s unable to identify 802 1 Q Tag In this case please set the corresponding port to Untagged properties 4 2 VLAN Member Based on the system VLAN mode can be divide...

Страница 36: ...01 to 15 to be the downlink ports so that the port 16 of the switch will forward the packets to the port 01 to 15 of the switch The Configuration is shown below Click Restore Default Load Default to r...

Страница 37: ...types the Receive Packet Transmit Packet the Transmit Packet Collision Count the Receive Packet Drop the Packet and the Receive Packet CRC error Packet After choosing type click the submit Update can...

Страница 38: ...Page 38 Revision 1 0 Note system does not automatically refresh the count must manually click on the refresh When the count value reaches the maximum value will be reset automatically...

Страница 39: ...e scheduling All High Before Low in strict accordance with the order of the priority from High to Low priority to send groups of higher priority queue when the higher priority queue is empty and then...

Страница 40: ...port can be bound 3 groups of MAC address the binding of MAC message will not be forwarded For example Select port selected 01 Binding selected enable MAC Address selected 00 0 a 5 a 01 01 01 after th...

Страница 41: ...essage other protocol Port packet is discarded Secure Port is said set TCP UDP filtering function switches WAN Port Protocol includes 20 different network protocols In addition UserDEF_a UserDEF_b and...

Страница 42: ...Chapter 8 Spanning Tree Settings 8 1 STP Bridge Settings There is an example of STP Bridge Setting STP mode disable stp rstp Bridge Priority 0 61440 Hello Time 1 10 seconds Max Age 6 40 seconds Forwar...

Страница 43: ...Page 43 Revision 1 0 8 2 STP Port Settings 1 STP Port Settings To set port priority and port path cost 2 STP Port Status To display port path cost priority forward status STP port states and so on...

Страница 44: ...Page 44 Revision 1 0...

Страница 45: ...0 8 3 Loopback Detection Settings 1 Loopback Detect Function Enable on Disable off 2 Auto Wake Up Enable on Disable off 3 Wake Up Time Interval Open Auto wake up there are loop of ports Discard the du...

Страница 46: ...ided into four strategies the port ID SA DA and SA DA as per hash logic relations based on relations System by default is the port ID type Note alone choose a port as Link Aggregation is void Settings...

Страница 47: ...ange is 1 16 DHCP Relay Option 82 state when selecting Enable its function is on when selecting Disable it s off 10 2 Relay Server Setting Add the Relay Server can add up to three Relay Server Enter t...

Страница 48: ...Page 48 Revision 1 0 click Add...

Страница 49: ...the local in Bin file format 2 Configuring Recovery Click on the Browse the file selection box will pop up open the configuration file in the corresponding local path Input password the default passw...

Страница 50: ...ms 400 ms 600 ms and 800 ms Disable shows no aging 2 VLAN Striding After the feature enabled even two ports are not in the same VLAN the switch will also forward destination MAC known single broadcast...

Страница 51: ...Page 51 Revision 1 0...

Страница 52: ...ld down the RESET button loosen after 5 seconds The switch will automatically restore the default Settings you can see the System LED flashing After the system LED restore normal flashing frequency i...

Страница 53: ...n Switches and network terminal Ethernet ports don t match each other Network setup is not correct Set the Ethernet ports working mode to make it match or set it to be adaptive work mode Check the net...

Страница 54: ...thernet based on 4B 5B signal coding and the use of two pair Cat5 twisted pair cable 100BASE FX EEE802 3 short terminology said 100 Mbps fast Ethernet based on 4B 5B signal coding Automatic Negotiatio...

Страница 55: ...ctrical connection MDIX Cross media interface it can send the sending signal of a device to the receiving end of another device and vice versa RJ 45 A 8 pin module connector used in Twisted pair link...

Страница 56: ...1 to 8 in turn Table 1 shows the function definition of each pin about the RJ 45 connector on the MDI mode function Table 2 shows the function definition of each pin about the RJ 45 connector on the...

Страница 57: ...iving data 2 RxData receiving data 3 TxData sending data 4 reserve 5 reserve 6 TxData sending data 7 reserve 8 reserve Network Cable Production Chart 2 Cat 5 twisted pair cable schematic diagram Pair...

Страница 58: ...requirements should choose respectively In the traditional network when the LAN cards connect with the hubs switches and so on using straight through cable When the connection between LAN card and LA...

Страница 59: ...on SIDE1 SIDE1 SIDE2 1 2 3 4 5 6 7 8 1 white orange 1 white green 2 orange 2 green 3 white green 3 white orange 4 blue 4 blue 5 white blue 5 white blue 6 green 6 orange 7 white brown 7 white brown 8 b...

Отзывы: