Inscape Data Link Power LPS3800-T1 Series Скачать руководство пользователя страница 3

Page | 3 
 

Safety Summary 

The following general safety precautions must be observed during all phases of operation of this 
instrument. Failure to comply with these precautions or with specific warnings elsewhere in this 
manual violates safety standards of design, manufacture, and intended use of the instrument. 
Inscape Data Corporation assumes no liability for the customer’s failure to 
comply with these requirements.  
 

Before Applying Power 

Verify that the product is set to match the available line voltage and all safety precautions are 
taken. 
 

Over Temperature Warning 

To prevent the switch from overheating, do not operate it in an area that exceeds the maximum 
recommended ambient temperature of (75°C). To prevent product cooling restriction, allow at 
least 3 inches (7.6 cm) of clearance around the product after installation. 
 

Ground the Instrument 

To minimize shock hazard, the instrument chassis and cabinet must be connected to an 
electrical ground. The instrument must be connected to the ac power supply mains through a 
three-conductor power cable, with the third wire firmly connected to an electrical ground (safety 
ground) at the power outlet. For instruments designed to be hard-wired to the ac power lines 
(supply mains), connect the protective earth terminal to a protective conductor before any other 
connection is made. Any interruption of the protective (grounding) conductor or disconnection of 
the protective earth terminal will cause a potential shock hazard that could result in personal 
injury.  
 
When installing the unit, always make the ground connection first and disconnect it last. 

 

Jewelry Removal Warning 

Before working on equipment that is connected to power lines, remove jewelry (including rings, 
necklaces, and watches). Metal objects will heat up when connected to power and ground and 
can cause serious burns or weld the metal object to the terminals. 

 

Do not Operate in Explosive Atmosphere 

Do not operate the product in the presence of flammable gases or fumes. 
 

 

Содержание Link Power LPS3800-T1 Series

Страница 1: ...opyright 2015 Inscape Data Corporation All Rights Reserved LinkPower AirEther AirGoogle and Inscape Data are trademarks of Inscape Data Corporation Disclaimer While every effort is made to ensure the...

Страница 2: ...at changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment The manufacturer is not responsible for any radio or T...

Страница 3: ...chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected t...

Страница 4: ...ct Conforms to the following safety standards Specification Description Regulatory Compliance Products with the CE Marking are compliant with the 89 336 EEC and 73 23 EEC directives which include the...

Страница 5: ...or Description Table 8 Grounding Protection 9 Grounding the Switch by Using the AC Power Cord 9 Power Redundancy UPS Input 10 RESET Switch System Reset 10 Installation Mounting 11 Connector Layout Dia...

Страница 6: ...ection can adapt to harsh outdoor environment Under the temperature of 30 70 C working at a full load 225W for IEEE802 3at 9 The four gigabit SFP fiber ports are capable of high bandwidth and for up t...

Страница 7: ...he next page Please note the following IP weatherproof rating when close the top cover 1 Closing the top cover by latch the weatherproof IP rating is IP66 2 Closing the top cover by 4 screws included...

Страница 8: ...wer_CLI_Configuration_User_Manual pdf Console Port Setup Manual http www inscapedata com manual LinkPower_Console_Port_Setup_Manual pdf Control Panel Diagram LED Indicator Description Table Indicator...

Страница 9: ...nsion has a PE Protective Earth terminal Figure 5 Aka Equipment Grounding Conductor 2 The ground contact in the power outlet is securely connected to the ground in the power distribution room or on th...

Страница 10: ...then the DC power functions as the main power When the DC power is used as the main power the actual power required will be based on the total power consumption fo the connected devices For example if...

Страница 11: ...set automatically Please be very cautious about the internal wires and cables and DO NOT CHANGE or INTERFERE ANY OF THE INTERNAL WIRES AND CABLES TO PREVENT DAMAGES TO THE SYSTEM Installation Mounting...

Страница 12: ...e used to cover the Sealing Insert if any of the hole is not used in order to maintain waterproof of the connector Optional Accessories The following optional accessories can be order if required 1 Ma...

Страница 13: ...Page 13 Product Dimensions Support Cable Gland and Conduit Connectors The Hole Size 1 Inch Diameter Wall Mount Pole Mount...

Страница 14: ...Page 14 ELECTRICAL PIN OUT DIAGRAM...

Страница 15: ...ite http www inscapedata com U S Headquarters Here s how to reach us if you d like to place an order or if you have questions concerns or need support Telephone Postal Mail North and South America Cus...

Отзывы: