Page | 10
Connector Layout Diagram:
Please note, the switch supports cable Gland and conduit waterproof connectors. The hole diameter for PoE
cables is 25 mm, and the hole diameter for power cable is 20 mm.
Support Cable Gland and Conduit Connectors
•
The hole Size of SFP & PoE Connectors is 25 mm
•
The Hole Size of AC Power Connector is 20 mm
Waterproof Ethernet, Fiber Optics, & Power Connector Assembly Diagram
Plastic Filler (Plug)
Note:
The Sealing Insert comes with one and three holes. The Plastic Filler (Plug)
MUST
be used to cover the Sealing
Insert if any of the holes is not used in order to maintain waterproof of the connector.
Grounding Protection:
The system provides the following way to ground the equipment for safety and protection of the system. It is
highly recommended that you’re to perform both grounding pro
cedures for maximum safety and protection of
your equipment. However, at least of the grounding MUST be performed; otherwise any product damage caused
by improper or no grounding will not be covered under warranty.
Grounding the Switch
If the installation site has no grounding strips or earth ground connection, then you must ground the switch
through the AC wire of the power cord. Please make sure that:
1.
The power cord extension has a PE (Protective Earth) terminal, Figure 5, Aka, Equipment Grounding
Conductor.
2.
The ground contact in the power outlet is securely connected to the ground in the power distribution
room or on the AC transformer side.
3.
The power cord is securely connected to the power outlet.