PARTS COUNTING
After the unit weight has been determined or entered it is possible to use the scale for
parts counting. The scale can be tared to account for package weight as discussed in
an earlier section.
After the scale is tared then the items to be counted are added and the "Count" display
will show the number of items computed using the weight and the unit weight.
It is possible to increase the accuracy of the unit weight at any time during the counting
process by entering the count displayed then pressing the SMPL key. You must be
certain the quantity displayed matches the quantity on the scale before pressing the
key. The unit weight will be adjusted based upon a larger sample quantity. This will give
greater accuracy when counting larger sample sizes.
AUTOMATIC PART WEIGHT UPDATES
The scales will automatically update the unit weight when a sample equal to less than
the sample already on the platform is added. A beep will be heard when the value is
updated. It is wise to check the quantity is correct when the unit weight has been
updated automatically.
This feature is turned off as soon as the number of items added exceeds the count
used as a sample.
TFCa Series only:
The Unit weight key is labelled Lb/Kg as this key has a dual function. When the
scale is at zero and the unit weight display is showing zero the key will change the
scale from pounds to kilograms. When a value is entered into the Unit Weight
Display this key is not active for changing the weighing units and the scale will
automatically use the value for the unit weight if the Lb/Kg (UNIT WT) key is
pressed within 5 seconds.