Inscale TCC 12A Скачать руководство пользователя страница 1

 

 

 

TFC  SERIES 

 

 

 

 

 

 

 

 

                  

         

Inscale Measurement Technology Ltd

Tel: Fax: Email:

+44(0)1

424

 2

00722

 +44(0)1424 443976

 

 

sales@inscale

-scales.co.uk

7 Heron Close, St. Leonards-on-Sea. East Sussex TN38 8DX United Kingdom

Http: www.

inscale-scales

.co.uk

 

Solutions in 

Weighing

 Technology

Inscale Measurement Technology Ltd follows a policy of continuous improvement and reserves the right to change specifications without notice. © October 2002

Содержание TCC 12A

Страница 1: ...cale scales co uk 7 Heron Close St Leonards on Sea East Sussex TN38 8DX United Kingdom Http www inscale scales co uk Solutions in Weighing Technology Inscale Measurement Technology Ltd follows a polic...

Страница 2: ......

Страница 3: ...change weighing units There are 3 models in each series with capacities up to 300 kg 660 Lb They all have stainless steel weighing platforms on an Steel base assembly and a display module mounted on a...

Страница 4: ...nits of Measure kg TFCa SERIES Model TFC 130a TFC 330a TFC 660a Maximum Capacity 130Lb 60kg 330Lb 150kg 660Lb 300kg Readability 0 01Lb 5g 0 02Lb 10g 0 05Lb 20g Resolution 1 13 000 1 15 000 1 16 500 1...

Страница 5: ...eld N A Balance Housing Indicator ABS Plastic Base Steel with Stainless Steel platform Pan Size 425mm x 525mm 16 7 x 20 7 Overall Dimensions wxdxh 425mm x 700mm x 950mm 16 7 x 27 5 x 37 5 Gross Weight...

Страница 6: ......

Страница 7: ...s Do not place near open windows Keep the scales clean Do not stack material on the scales when they are not in use INSTALLATION of TFC SERIES The pillar is attached to the base using a bracket that m...

Страница 8: ...bracket with the flanges engaged in the groves on the base Attach the cable from the base to the connector on the rear of the indicator Attach the power supply module to the connector on the side of...

Страница 9: ...dd the current count to the accumulator Up to 99 values or full capacity of the weight display can be added MR To recall the accumulator memory Smpl or Used to input the number of items in a sample Un...

Страница 10: ...GHT DISPLAY This display will show the unit weight of a sample This value is either input by the user or computed by the scale The unit of measure is grams on all scales with kilogram weight units or...

Страница 11: ...w the number of items on the scale or the value of the accumulated count See OPERATION section Indicators will show when a value has been entered into memory when the arrow above the Memory legend is...

Страница 12: ...o the scale by pressing the ZERO key if necessary The zero indicator will be on Place a container on the platform a value for its weight will be displayed Press the TARE key to tare the scale The weig...

Страница 13: ...ht Then when the full container is put on the platform the tare value will be subtracted from the gross weight displaying only the net weight of the contents If the value input is not consistent with...

Страница 14: ...ty of items on the scale After the weight display is stable enter the quantity of items using the numeric keys followed by the SMPL key The number of units will be displayed on the Count display and t...

Страница 15: ...will give greater accuracy when counting larger sample sizes AUTOMATIC PART WEIGHT UPDATES The scales will automatically update the unit weight when a sample equal to less than the sample already on t...

Страница 16: ...n added to the accumulation memory The values will be displayed for 2 seconds before returning to normal The scale must return to zero or a negative number before another sample can be added to the me...

Страница 17: ...will be charged If the LED is green the battery has a full charge If it is Red the battery is nearly discharged and yellow indicates the battery is being charged As the battery is used it may fail to...

Страница 18: ...subminiature socket Pin 2 Output Pin 3 Input not used at this time Pin 7 Signal Ground Data Format Normal Output Data Format Memory Recall Print GS 123 4 Kg GS for Gross weight NT for net weight with...

Страница 19: ...TARE key At any time press the ZERO key to return to weighing Weight Display Description F1 CAL See the calibration section for details F2 dI Set the scale increment Press the Unit Wt key to show the...

Страница 20: ...e display will show LOAd place the calibration weight on the scale and press the TARE key The scale will calibrate and then start the initial check procedure counting form 9 to 0 Remove the weight dur...

Страница 21: ...OR CODE DESCRIPTION POSSIBLE CAUSES Err 4 Initial Zero is greater than allowed typically 4 of maximum capacity when power is turned on or when the ZERO key is pressed Weight on the pan when turning th...