STATISTICS OPERATION  

 

The printer has 2 switches to assist in printing statistical information for data received 

from balances. The Paper Feed switch (Grey button)  normally advances the paper. In 

addition the printer has another switch, PRINT (Red button) that is used to send the 

Print command to balances and in conjunction with the Paper Feed for some 

operations. 

 

When power is turned on the Statistics function is automatically enabled if SW8 is ON. 

 

Send data to the printer from the scale by pressing the PRINT key on the printer, 

pressing the PRINT key on the scale or setting the scale to automatically print when 

stable.  

 

During data collection the last data can be erased if in error by pressing the PF then 

PRINT switch in sequence. 

 

Continue to collect data in this manner. At any time data collection can be stopped by 

holding down Paper Feed and  then pressing PRINT and releasing both buttons. 

 

A message showing the options is displayed. 

 

 

PRINT 

 

 

Press PRINT to get a Statistics Report 

 

PRINT + PF   

Start a new Series by holding PRINT then pressing the 

 

 

 

 

Paper Feed switch 

 

PF + PRINT   

Continue by holding Paper Feed then pressing the 

 

 

 

 

PRINT switch 

 

 

The Statistics Report consists of the following information. 

 

 

number of results 

sum x  

sum of all results 

 

average 

 

standard deviation (n-1) 

srel   

relative standard deviation 

min   

minimum value 

max   

maximum value 

 

 

=  

range (max – min) 

 

The equations used are: 

 

 

(

)

2

1

=

n

x

x

s

i

x

s

srel

=

Содержание IN301

Страница 1: ...443976 sales inscale scales co uk 7 Heron Close St Leonards on Sea East Sussex TN38 8DX United Kingdom Http www inscale scales co uk Solutions in Weighing Technology Inscale Measurement Technology Ltd...

Страница 2: ...d to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if no...

Страница 3: ...istical information about the data Alternately it can be set as a standard printer to collect but without the statistics The printer comes preset to work with the default RS 232 interface found on the...

Страница 4: ...60Hz USA Environment 5 to 35 C 10 to 80 humidity non condensing Printer Dot matrix Thermo printer Bi directional printing 0 75 lines per second 40 or 80 characters per line Paper 112mm thermo paper PH...

Страница 5: ...d the Paper Feed button until the paper passes through the printer Do not pull paper or force through the slot If the paper does not feed easily check you are using the paper entry slot and there are...

Страница 6: ...Set the switches as desired and then turn the printer on With SW8 Off With SW8 On Statistics disabled Statistics enabled 1200 2400 4800 9600 baud Select Inscale Balances SW1 on off on off Off SW2 on o...

Страница 7: ...ter Inscale Balances 5 pin DIN connector 9 Pin D Subminiature Socket Pin 1 RXD Pin 3 Data from Scale Pin 2 DTR Pin 1 Not used by Inscale balances Pin 3 GND Pin 5 Signal ground Pin 4 nu Pin 5 TXD Pin 2...

Страница 8: ...ically print when stable During data collection the last data can be erased if in error by pressing the PF then PRINT switch in sequence Continue to collect data in this manner At any time data collec...

Страница 9: ...s PRINT to continue with the data collection procedure or hold PRINT then press Paper Feed to start a new set of data collection If the printer detects a change in format or an error during data colle...

Страница 10: ...e time setting mode Regardless of internal switch settings proceed as follows An ASCII string must be sent to the printer to set the date and time One method of doing this is to connect the printer to...

Страница 11: ......

Страница 12: ...gn of the equipment without notice All information contained within this publication was to the best of our knowledge timely complete and accurate when issued However we are not responsible for misimp...

Отзывы: