8 TECHNICAL DATA
8.1 General
8.2 Aerosol characteristics in accordance
with EN 13544-1 appendix CC
The output of the nebuliser depends on the medication being
used. Consequently, the following data may not apply for medi-
cations that exist as suspensions or are very viscous. If in doubt,
ask the manufacturer of the medication concerned for advice.
Determination of particle size
Fill the INQUA
®
nebuliser with 3 ml of a 2.5% test solution and
then attach the INQUA
®
nebuliser to an impactor (NGI™ = Next
Generation Impactor™) and run for 3 minutes.
Recommended nebuliser gases:
Air
Minimum flow:
3.0 l/min.
Corresponding minimum operating
pressure:
50 kPa (0.5 bar)
Maximum flow:
6.0 l/min.
Corresponding maximum operating
pressure:
200 kPa (2.0 bar)
Minimum fill volume:
2 ml
Maximum fill volume:
8 ml