background image

 

14 

8.Technical Specifications 

2021/11 

8.

 

Technical Specifications  

8.1. 

 

TECHNICAL SPECIFICATIONS 

 

 

Flow at 900 rpm.  ..................................................................  

28 l/min. 

Flow at 750 rpm.  ..................................................................  

23 l/min. 

Flow at 500 rpm.  ..................................................................  

16 l/min. 

Flow at 300 rpm.  ..................................................................  

10 l/min. 

Maximum operating pressure  ................................................  

6 bar (87 PSI) 

Maximum viscosity ................................................................  

40.000 mPas 

Operating temperature  .........................................................  

-10 ºC a +85ºC 
 14 ºF a 185 ºF  

Sound level  ..........................................................................  

60-80 dB(A) 

Discharge connection  ...........................................................  

R 1 

½”

 

Pump tube diameter  .............................................................  

54 mm. 

 

 

 

Materials 

 

Stator ......................................................................................  NBR black according FDA 
Parts in contact with the product ...............................................  AISI 316L 
Other parts in stainless steel .....................................................  AISI 304 
Gaskets in contact with the product ...........................................  NBR 
Other optional stator materials ..................................................  NBR white, EPDM 
Surface finish ...........................................................................  Standard polished 
 

 

Mechanical seal 

 

Type of seal  .........................................................................  

Single inside seal 

Stationary part material  ........................................................  

Silicon 

Rotary part material  .............................................................  

Silicon 

Seals material  ......................................................................  

Viton 

 

 

 

 

 

Whenever the noise level in the area of operation exceeds 85 dB(A) use special protection. 

 
 

8.2. 

 

WEIGHT 

 

 

Pump type  

 

Weight 

without drive 

[Kg] 

Weight with 

motor 

[Kg] 

Weight with 

gear motor 

[Kg] 

KVB-25 

36 

33 

 
 

 
 

 
 
 

 
 

 
 

 

Содержание KIBER KVB-25

Страница 1: ...ND MAINTENANCE INSTRUCTIONS KIBER KVB 25 INOXPA S A c Telers 54 Aptdo 174 E 17820 Banyoles Girona Spain Tel 34 972 57 52 00 Fax 34 972 57 55 02 Email inoxpa inoxpa com www inoxpa com Original Manual 01 631 30 00EN D 2021 11 ...

Страница 2: ......

Страница 3: ......

Страница 4: ... by rotating parts of the equipment Danger Electricity Danger Caustic or corrosive agents Danger Suspended loads Danger to the proper operating of the machine Obligation to ensure safety at work Use of safety goggles obligatory 1 4 GENERAL SAFETY INSTRUCTIONS Please read the instruction manual carefully before installing and commissioning the pump Should you have any doubts or queries contact INOX...

Страница 5: ...ntenance and repair procedures Potential electrical mechanical and chemical hazards Atmospheric conditions in the room could be hazardous due to the release of chemical substances 1 4 5 Warranty We wish to point out that any warranty issued will be null and void and that we are entitled to an indemnity for any civil liability claim for products which might be filed by third parties if Operation an...

Страница 6: ...lications 6 4 Installation 4 1 Pump reception 7 4 2 Transport and storage 7 4 3 Location 8 4 4 Electrical installation 8 5 Start up 5 1 Start up 9 6 Operating problems 7 Maintenance 7 1 General maintenance 11 7 2 Storage 11 7 3 Cleaning 11 7 4 Pump disassembly Assembly 12 8 Technical Specifications 8 1 Technical specifications 14 8 2 Weight 14 8 3 Dimensions 15 8 4 Pump section 16 8 5 Parts list 1...

Страница 7: ...luid When the rotor turns within the stator the cavities move longitudinally from the suction area to the discharge nozzle This kind of pumps is suitable for pressures from 6 bar All pump parts in contract with the pumped product are manufactured in AISI 316L stainless steel The stator is manufactured in NBR according to the FDA norm and the standard sealing is EN 12756 mechanical seal This equipm...

Страница 8: ...om INOXPA Unpack the pump and check the following The pump suction and delivery connections removing the remains of any packing material Check that the pump and the motor have not suffered any damage Should the pump not be in proper condition and or does not have all the parts the haulier must draw up a report as soon as possible with regard to the same 4 1 1 Pump identification and marking Qm h k...

Страница 9: ...trol systems may still carry an electric charge even when disconnected Contact with them may put the safety of operators at risk or cause irreparable damage to the material Before manoeuvring the pump make sure that the electric box is switched off Connect the motor in accordance with the instructions supplied by the manufacturer of the same Check the direction of the rotation see the signaling la...

Страница 10: ...on the discharge pipe Check that the stator is submerged The pump must NEVER rotate without liquid Check that the rotation direction of the motor is correct Check that the power supply matches the rating indicated on the motor plate 5 1 2 Checks to be carried out on putting the pump into operation Check to make sure that the pump is not making any strange noises Check to see if the absolute inlet ...

Страница 11: ...is too high If necessary decrease the load losses by increasing the diameter of the piping for example 3 The viscosity of the liquid is too high Decrease the viscosity by heating the liquid for example 4 The temperature of the liquid is too high Decrease the temperature of the liquid by cooling it 5 Mechanical seal either damaged or worn Replace the seal 6 Unsuitable stator or O ring for the liqui...

Страница 12: ...anical seal Periodically check that there are no leaks in the shaft area Should there be any leaks in the mechanical seal area replace the same pursuant to the instructions given in the section entitled Stripping and Assembly of the pump 7 2 STORAGE Before being stored the pump must be completely emptied of liquids Avoid as far as possible the exposure of the parts to excessively damp atmospheres ...

Страница 13: ...ith a left threaded hexagonal nut Place the seal stop ring 31A to the stator 22 and with help of the rod in the hole of the stator screw it to the casing 01 till it stops remember that it is left threaded 7 4 2 Mechanical seal Disassembly Continue disassembling the pump in the horizontal position Loosen the pin 55 of the seal stop ring 31 and slide it pull it out together with the rotating part of...

Страница 14: ...e hexagonal screws 52B and 52C to pull out the flange support 04 and the drive support 06 Assembly Drill a hole in the drive shaft 93 as indicated on the figure below Mount the shaft 05 in the hole of the drive and fix it with the hexagonal screw 52A and hexagonal nut 54 Place the flange support 04 and the drive support 06 to the flange of the drive fasten the hexagonal screws 52B and 52C and flat...

Страница 15: ...er 54 mm Materials Stator NBR black according FDA Parts in contact with the product AISI 316L Other parts in stainless steel AISI 304 Gaskets in contact with the product NBR Other optional stator materials NBR white EPDM Surface finish Standard polished Mechanical seal Type of seal Single inside seal Stationary part material Silicon Rotary part material Silicon Seals material Viton Whenever the no...

Страница 16: ...2021 11 8 Technical Specifications 15 8 3 DIMENSIONS ...

Страница 17: ...16 8 Technical Specifications 2021 11 8 4 PUMP SECTION ...

Страница 18: ...Mechanical seal 1 09 Seal cover 1 AISI 316L 21 Rotor 1 AISI 316L 22 Stator 1 AISI 316L black NBR 24 Connecting rod 1 AISI 316L 31 Seal stop ring 1 AISI 316L 31A Washer 1 AISI 316L 52 Hexagonal screw 1 A2 52A Hexagonal screw 1 A2 52B Hexagonal screw 2 A2 52C Hexagonal screw 2 A2 53 Flat washer 2 A2 53A Flat washer 4 A2 54 Hexagonal nut 2 A2 55 Pin 1 A2 80 O ring 1 NBR 93 Drive 1 ...

Страница 19: ...NOTES ...

Страница 20: ...IBA JOHANNESBURG SANTA ROSA Tel 213 21856363 21851780 Tel 27 117 945 223 Tel 1 7075 853 900 Fax 213 21854431 Fax 27 866 807 756 Fax 1 7075 853 908 e mail inoxpalgerie inoxpa com e mail sales inoxpa com e mail inoxpa us inoxpa com INOXPA UK LTD S T A PORTUGUESA LDA INOXPA ITALIA S R L SURREY VALE DE CAMBRA BALLO DI MIRANO VENEZIA Tel 44 1737 378 060 079 Tel 351 256 472 722 Tel 39 041 411 236 Fax 44...

Отзывы: