6. Start-up
Read carefully the instructions in chapter
5. Installation
before start-up the valve.
Before putting the valve or the actuator into service the following must be taken into consideration:
- check that the piping and valve are completely free of possible traces of welding slag or other
foreign particles. Clean the system if is necessary,
- check to make sure the valve moves smoothly. If necessary, lubricate it with special grease or
soapy water,
- check for possible leaks, and make sure the pipes and their connections are sealed and do not
have any leaks,
- if the valve has been supplied with an actuator, make sure that the alignment of the valve shaft
and the actuator shaft enables smooth movement,
- check that the compressed air pressure at the inlet of the actuator matches what is indicated in
chapter
9. Technical Specifications
,
-
consider the quality of the compressed air, according to the specifications described in chapter
9. Technical Specifications
,
- activate the valve.
Before start-up, the persons in charge must be duly informed about how the valve works
and the safety instructions to follow. This instruction manual will be available to person-
nel at all times.
ATTENTION
Do not modify the operating parameters for which the valve has been designed without
prior written authorisation from INOXPA.
Do not touch the moving parts of the coupling between the actuator and the valve when
the actuator is connected to the compressed air supply.
¡Burn hazard! Do not touch the valve or the pipes when hot fluids are circulating or when
cleaning and/or sterilization are being carried out.
Start-up
13
INOXPA S.A.U.
10.260.30.01EN · (A) 2022/09