![Inovonics FA416 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/inovonics/fa416/fa416_installation-instructions-manual_2064866005.webp)
© 1997 Inovonics Wireless Corporation LIT-FA416-INSTALL
5
02304e 23-Oct-02
Technical Specifications:
Dimensions (housing):
6.38" x 3.60" x 1.10"
Weight:
6.9
oz.
9 oz FA416R and FA416DR
Environmental:
Operating
temperature:
32
°
-140
°
F (0
°
-60
°
C)
Relative Humidity:
90% (non-condensing)
Electrical:
Power Requirement:
11 - 14 VDC, 450 mA
Power Consumption:
60 - 85 mA (without display)
75 - 225 mA (with display)
450 mA (with display and 5 relays active)
Typical:
60 mA (without display)
75 mA (with display)
115 mA (with display and 1 relay active)
Relay specifications:
1A @ 28VDC
0.5A @ 30VAC (resistive load)
Receiver:
Type:
frequency-hopping spread spectrum
Operating frequency:
902-928 MHz
Installation:
Power
: Supply power and ground to terminals marked
13.6V
and
GND
on the terminal block.
Mounting:
Use supplied hardware to attach FA416 housing to wall or surface. Where possible, orient the
antenna side of the receiver toward the majority of transmitters on the site. This enhances reception.
Opening the housing:
Insert a small flat screwdriver behind pry point indicator nubs on top or bottom of the
housing cover. Gently twist or pry the housing cover away from the base.
Installing the FA516 display:
Always disconnect power from the FA416 receiver before installing or removing
the FA516 Display Module. Visually check the mating of pins and header to make sure that all pins are seated
in the header.
Note: If the FA516 display is purchased separately from the FA416, it will be packaged with a housing cover
and graphic panel to replace the original FA416 cover. (Specify housing type.)
Installing the case tamper:
Connect leads from the Case Tamper terminal block to a zone on the hardwire
panel. The switch is N/C with the cover on.
Attention: The FA540 relay module is not compatible with the new FA416 and FA416D receivers.
If
relay outputs are required, the receiver unit must be either the FA416R or the FA416DR . The FA541 single-
relay module can still be used to provide relay operation off of individual outputs.