© 1997 Inovonics Wireless Corporation LIT-FA416-INSTALL
11
02304e 23-Oct-02
Appendix A:
Default Receiver Parameters
Active
on
Output Condition Programmable Options
1
Alarm
Alarm / Alarm+Tamper / Disabled
2
Alarm
Alarm / Alarm+Tamper / Disabled
3
Alarm
Alarm / Alarm+Tamper / Disabled
4
Alarm
Alarm / Alarm+Tamper / Disabled
Transmitter Default
Condition Mode
Alarm
Follower
Follower / Momentary / Latching
Inactive
Follower
Follower / Momentary / Latching
Tamper
Latching
Follower / Momentary / Latching
Low Batt
Latching
Follower / Momentary / Latching
Default Momentary Output time:
4 seconds
1 - 16 seconds
Default Receiver Parameters:
System ID:
(randomly assigned at factory)
0 - 255
Point supervision:
Yes
Yes / No
Supervision window:
4 hours
1 - 99 minutes, 1 - 99 hours
Access code:
3446
0000 - 9999
Vision Plus compatible:
No
Yes / No (Refer to FA116 user manual)
Programmable Options may be modified only by using the FA116 Executive Programmer.
Appendix B:
Default Transmitter Parameters
Switch Output Check-in
Point Contact Channel Seconds
1*
N/O 1
60
2*
N/O 2
60
3*
N/C 3
60
4*
N/C 4
60
5
N/O 1
60
6
N/O 2
60
7
N/O 3
60
8
N/O 4
60
9
N/C 1
60
10
N/C 2
60
11
N/C 3
60
12
N/C 4
60
13
N/C 1
60
14
N/C 2
60
15
N/C 3
60
16
N/C 4
60
*Only points 1 through 4 can be programmed from the FA416 and FA416R. Points 1-16 may be programmed from the FA416D and
FA416DR. The FA116 programmer can be used to change any transmitter options on any receiver for all 16 points.
Note: Portable panic transmitters which may be taken off-site or out of range or should nonetheless be programmed to check in. After a
transmitter has been programmed, the receiver programming for that point should be changed (with an FA116) so that the transmitter will
not be declared inactive.