8/22/19 357-05042-02 Rev A © Inovonics, 2019 - www.inovonics.com
EN1215EOL Universal with Wall Tamper
Installation Instructions
1 Overview
The Inovonics EN1215EOL universal with wall tamper can be
used with any standard contact or sensor. A 2.2K ohm end of line
resistor is included with the EN1215EOL, and is required for
operation.
The EN1215EOL includes a wall tamper switch. The tamper
condition must be defined within the control panel as a trouble
condition when the system is disarmed, and as an alarm
condition when the system is armed.
The universal with wall tamper is available in North America,
Australia and New Zealand; the radio frequency band has been
configured for the appropriate geographic area at the factory.
Note:
For UL installations, refer to the
EN4216MR Installation
and Operation Manual
, the
EN4232MR Installation and
Operation Manual
, or the
EN7290 EchoStream Receiver/
Interface for Honeywell VISTA Panels Installation Instructions
.
Note:
For UL installations, the switch contact must be in the
same room as the EN1215EOL.
Note:
The cable length from the switch contact must not to
exceed 10 feet.
Note:
For UL installations, the EN1215EOL must be installed in
accordance with UL 681.
1.1 Inovonics Contact Information
If you have any problems with this procedure, contact Inovonics
Wireless technical services:
• E-mail: [email protected].
• Phone: (800) 782-2709.
1.2 Universal with Wall Tamper Internal
Components
Figure 1
Universal with wall tamper internal components
1.3 What’s In The Carton
• Two wall mount screws.
• Two wall mount anchors.
• Two selection jumpers.
• One 3.0V lithium battery.
• One housing closure screw.
• One 2.2K ohm end of line resistor.
2 Installation and Startup
2.1 Installation Notes
• These products are designed to be installed and maintained
by professional security technicians.
• Products are intended for indoor use.
• Manually test all products weekly.
2.2 Install the Battery
1.
Use your thumb to press the housing release tab on the
bottom of the transmitter; separate the housing.
2.
Install the battery.
3.
Press the reset button to initialize the transmitter.
4.
Test the transmitter and ensure appropriate response.
2.3 Select Input Type and Wire Resistor
The N/O-N/C selection pins allow the choice of a normally open
or normally closed state for the contact circuit wired to the input
terminal.
The transmitter is shipped set for normally closed, with no
selection jumper on the N/O selections pins.
Set for Normally Open Operation
1.
Place a selection jumper on the selection pins to select
normally open.
2.
Use 22 AWG wire to wire the 2.2K ohm resistor in parallel
with the N/0 contact per Figure 2. The distance from the
external contact to the EN1215EOL must not exceed 10 feet
(3 meters).
3.
Press the reset button to complete configuration.
Figure 2
Wired for N/O operation
Normally Closed Operation
1.
Remove the selection jumper from the selection pins.
2.
Use 22 AWG wire to wire the 2.2K ohm resistor in series with
the N/C contact per Figure 3. The distance from the external
contact to the EN1215EOL must not exceed 10 feet (3
meters).
3.
Press the reset button.
Figure 3
Wired for N/C operation
2.4 Register the EN1215EOL
Transmitters must be registered with the system in order to be
monitored and supervised. When supervised, the transmitter will
send a check-in message to the receiver every three minutes.
Each transmitter has a unique factory-programmed identification
number.
Refer to the receiver installation instructions for details on
registering a transmitter.
1.
When prompted by the receiver to reset transmitter, press
the reset button.
2.
Replace the cover.
3.
Test the transmitter and ensure appropriate response.
For product and installation videos visit us at
www.inovonics.com/videos or use the QR
code below.
A
Combined housing/wall tamper
switch
B
N/O - N/C selection pins
C
Input terminal
D
Reset button
E
Wall-mount screw holes
F
Housing closure screw hole
A
B
C
D
E
E
F