background image

8/22/19 357-05042-02 Rev A © Inovonics, 2019 - www.inovonics.com

EN1215EOL Universal with Wall Tamper

Installation Instructions

1 Overview

The Inovonics EN1215EOL universal with wall tamper can be 

used with any standard contact or sensor. A 2.2K ohm end of line 

resistor is included with the EN1215EOL, and is required for 

operation.

The EN1215EOL includes a wall tamper switch. The tamper 

condition must be defined within the control panel as a trouble 

condition when the system is disarmed, and as an alarm 

condition when the system is armed.

The universal with wall tamper is available in North America, 

Australia and New Zealand; the radio frequency band has been 

configured for the appropriate geographic area at the factory.

Note: 

For UL installations, refer to the 

EN4216MR Installation 

and Operation Manual

, the 

EN4232MR Installation and 

Operation Manual

, or the 

EN7290 EchoStream Receiver/

Interface for Honeywell VISTA Panels Installation Instructions

.

Note: 

For UL installations, the switch contact must be in the 

same room as the EN1215EOL.

Note: 

The cable length from the switch contact must not to 

exceed 10 feet.

Note: 

For UL installations, the EN1215EOL must be installed in 

accordance with UL 681.

1.1 Inovonics Contact Information

If you have any problems with this procedure, contact Inovonics 

Wireless technical services:

• E-mail: [email protected].

• Phone: (800) 782-2709.

1.2 Universal with Wall Tamper Internal 

Components

 Figure 1  

Universal with wall tamper internal components

1.3 What’s In The Carton

• Two wall mount screws.

• Two wall mount anchors.

• Two selection jumpers.

• One 3.0V lithium battery.

• One housing closure screw.

• One 2.2K ohm end of line resistor. 

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be installed and maintained 

by professional security technicians.

• Products are intended for indoor use.

• Manually test all products weekly.

2.2 Install the Battery

1.

Use your thumb to press the housing release tab on the 

bottom of the transmitter; separate the housing.

2.

Install the battery.

3.

Press the reset button to initialize the transmitter.

4.

Test the transmitter and ensure appropriate response.

2.3 Select Input Type and Wire Resistor

The N/O-N/C selection pins allow the choice of a normally open 

or normally closed state for the contact circuit wired to the input 

terminal.

The transmitter is shipped set for normally closed, with no 

selection jumper on the N/O selections pins.

Set for Normally Open Operation

1.

Place a selection jumper on the selection pins to select 

normally open.

2.

Use 22 AWG wire to wire the 2.2K ohm resistor in parallel 

with the N/0 contact per Figure 2. The distance from the 

external contact to the EN1215EOL must not exceed 10 feet 

(3 meters).

3.

Press the reset button to complete configuration.

 Figure 2  

Wired for N/O operation

Normally Closed Operation

1.

Remove the selection jumper from the selection pins. 

2.

Use 22 AWG wire to wire the 2.2K ohm resistor in series with 

the N/C contact per Figure 3. The distance from the external 

contact to the EN1215EOL must not exceed 10 feet (3 

meters).

3.

Press the reset button.

 Figure 3  

Wired for N/C operation

2.4 Register the EN1215EOL

Transmitters must be registered with the system in order to be 

monitored and supervised. When supervised, the transmitter will 

send a check-in message to the receiver every three minutes. 

Each transmitter has a unique factory-programmed identification 

number.

Refer to the receiver installation instructions for details on 

registering a transmitter.

1.

When prompted by the receiver to reset transmitter, press 

the reset button.

2.

Replace the cover.

3.

Test the transmitter and ensure appropriate response.

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.

A

Combined housing/wall tamper 

switch

B

N/O - N/C selection pins

C

Input terminal

D

Reset button

E

Wall-mount screw holes

F

Housing closure screw hole

A

B

C

D

E

E

F