— 31 —
RTC Battery
The Real Time Clock has a backup battery located on the rear
of the front-panel board. This is a 3V CR2032 flat ‘coincell’
battery with the
+
side facing out. Replace the battery when
RTC Battery:
voltage drops to 2V.
Time Server
We have provided a reliable default time server, which is
1.inovonicsinc.pool.ntp.org
. If you must change the server be-
cause of some corporate edict, overtype the
Server:
entry with
your alternate and click
Save
.
ADMINISTRATIVE MATTERS
Security and
Passwords
SOFIA 567 access may be protected by passwords, which must
then be entered before any changes can be made. Either the
same or separate passwords may be assigned to lock out the
front-panel knob and/or Web interface access.
Under the
Security
heading, enter the
Front Panel:
and
Webpages:
fields to type-in a password for limiting access to either or both
avenues of approach. Click
Save
to lock passwords into non-
volatile memory.
NOTE:
Passwords will appear in clear text on both the front
panel OLED and Web interface screens, but of course only
trusted and authorized, logged-in users will be able to view
those screens.
Once the password is saved, no Web interface screen is accessi-
ble. And on the front-panel,
Now Playing
will be the only screen
that can be viewed.
With respect to front-panel access, the SOFIA 567 will lock any
time the screen times-out (goes dim or dark) after the unit is
untouched for the programmed-in timeout period. The unit
may be locked immediately by holding down the
Back
button
for a few seconds.
Signing In
When password protection is in place, at the installation site
you will be prompted to enter the password through the front-
panel OLED screen and jog knob before any menu can be ac-
cessed other than
Now Playing
. Use the knob to spell-out the
password, and then highlight
Save
and push the knob. This will
be necessary each time the unit times out to a dark or dim
screen.
When working on a protected unit over an extended period, you
can avoid the frustration of having to keep re-entering a pass-
word from the front panel by resetting the
Admin / Display /
Timeout
setting to
60 min
. From the
Admin / Security
screen you
could also repeatedly push
Del
to delete the password, but of
course jot it down first so you can put it back in when finished.
Содержание AM SiteStreamer+ SOFIA 567