background image

— 25 — 

authorized listeners.  The 

Max Listeners:

  slider  can  be  set  be-

tween 

0

 and 

10

Once changed, 

Stream

 settings must be saved by clicking on the 

Save

  bar.    Note  that  this  does  reset  the  utility,  disconnecting  

any current listeners, who then must log back on. 

General Purpose 

Outputs 

The rear-panel  GPOs  serve  as  ‘tally’  outputs  for  SOFIA  567 

alarms.    These  rear-panel  terminals  give  access  to  closures  to  

(or  opens  from)  ground  for  any  four  alarms  selected  from  the  

field of five (plus 

None

). 

Although the three alarms have been preprogrammed under 

the  Type:  listing,  each  GPO  may  be  programmed  separately.    

The 

Output #

 numbers on this Web interface page correspond to 

the four numbered terminals on the back of the unit.  +5V and 

ground are also provided on the terminal strip. 
In  the  example  shown 

here, 

Output 1

 has been 

Polarity:

-programmed  to 

deliver  an 

Active Ground

 

to GPO terminal 1 for an 

alarm 

Type:

 of 

Audio Loss

.  

It could as easily have been set to deliver ground on that termi-

nal all the time, and then go 

Active Open

 (ungrounded) when the 

alarm is received.  The other GPOs are programmed in identical 

fashion. 
The 

Status:

  line  in  this  example  shows  that  

Output 1 is Inactive

that is, the assigned 

Audio Loss

 alarm has not been tripped. 

NETWORK SETUP AND INTERNET ACCESS 

Obviously, if Web interface pages are appearing on your screen, 

what  follows  here  must  already  have  been  addressed.    Getting  

up-and-running through front-panel setup was covered on Page 

12, so most information here may turn out to be redundant. 

IP Setup 

With 

Mode:

  set to 

DHCP

, your router 

automatically assigns the SOFIA 567 

an 

IP Address:

 and will populate the 

four associated fields, although they 

will be ‘grayed-out’ and you won’t be 

able  to  edit  the  data  in  those  fields.    However,  if  

Mode:

  is 

changed to 

Static IP

, then you must make the appropriate en-

tries in all four fields. 

Assigning a 

Hostname 

You may change the default name 

SOFIA567 

to something else, 

either to personalize the equipment name or to differentiate 

one SiteS  from another on the same network.  All you 

need do is to select and overtype the default 

Hostname:

 using 

all uppercase letters and without using any spaces.  Be sure to 

click the 

Save

  bar  at  the  bottom  once  the  entry  are  finalized.  

Содержание AM SiteStreamer+ SOFIA 567

Страница 1: ...SOFIA 567 AM SiteStreamer Installation User Guide www inovonicsbroadcast com...

Страница 2: ......

Страница 3: ...0 0 0 Inovonics Inc 5805 Highway 9 Felton CA 95018 Tel 831 458 0552 Fax 831 458 0554 Register online at www inovonicsbroadcast com PRODUCT REGISTRATION RECORD SOFIA 567 Serial No _____________ Purchas...

Страница 4: ...2...

Страница 5: ...ns Power 10 Radio Frequency Interference RFI 10 Ground Loops 10 INPUTS OUTPUTS AND PORTS Antenna Input and Considerations 10 Analog Line Outputs 10 Unbalanced Operation 11 AES Digital Line Output 11 A...

Страница 6: ...ING Audio Level Metering 18 Histograms 19 The BandScanner Utility 20 ALARMS Alarm Status 21 Audio Loss 21 Low Signal 22 Overmodulation 22 Alarm Logging 22 SETUP Radio Settings 23 Audio Outputs 23 Gene...

Страница 7: ...p 29 Recipients Send To 29 Notifications Send What 30 TIME SETUP Time and DST 30 Presentation Formats 30 RTC Battery 31 Time Server 31 ADMINISTRATIVE MATTERS Security and Passwords 31 Signing In 31 Lo...

Страница 8: ...ll digital SDR Software Defined Radio off air re ception of medium wave analog AM stations Stays on channel and holds user settings through sig nal and power losses Provides analog AES3 digital Web st...

Страница 9: ...10 sim ultaneous listeners Alarms Audio Loss Silence Sensor Alarm has programmable On Off thresholds and Time On Off intervals Low Signal Alarm and reset trigger levels are independently adjustable r...

Страница 10: ...ake the product almost entirely DSP based with virtually all functionality provided through firmware coding The Block Diagram pre sented here illustrates product basics in an easily understood form al...

Страница 11: ...g damage sustained due to improper packing for return may invalidate the Warranty IT IS IMPORTANT to register the Warranty of your SOFIA 567 This assures coverage of the equipment under Warranty terms...

Страница 12: ...e optional rack mount chassis should satisfy this requirement INPUTS OUTPUTS AND PORTS Antenna Input and Considerations The rear panel ANTENNA input is a BNC female a ubiquitous connector worldwide wi...

Страница 13: ...Port and Levels The Dante compliant AoIP Audio over Internet Protocol out put appears at the rear panel RJ45 AoIP PORT This port is in dependent of the SOFIA 567 LAN PORT network connection The AoIP...

Страница 14: ...ary to get the unit up and running THE SOFIA 567 FRONT PANEL All setup and operating adjustments of the SOFIA 567 are un der firmware control There are no jumpers switches or me chanical potentiometer...

Страница 15: ...ng on Page 21 Level Meters LED segment meters E are marked LEFT and RIGHT signifying the two dual mono program audio outputs that deliver an identical signal to both output connectors These are audio...

Страница 16: ...p Radio De Emphasis select Spacing select Audio Outputs Analog Level select Digital Level select AoIP Level select General Purpose Outputs Output 1 4 select Type select Polarity set Status display Net...

Страница 17: ...address information turn the knob to scroll down Assigning a Fixed IP Address To assign the SOFIA 567 a fixed IP address clear the DHCP box and then navigate through the various fields on this screen...

Страница 18: ...casual au dio streaming Web listening plus the separate AoIP streaming utility and the rear panel analog and AES digital program line outputs In other words whatever station you tune will be heard on...

Страница 19: ...n this ar ea of the Now Playing Webpage and on the Alarms Webpage where the alarm trigger and reset parameters are set Alarm specifics and setup procedures begin on Page 21 In addition to the alarm st...

Страница 20: ...e off settings that will dictate the Rotation Time Sec setting See the Alarms discus sion beginning on Page 21 The Status display gives a second by second countdown of ro tation time GRAPHS METERING A...

Страница 21: ...k anywhere in the display area to cycle through the options The upper graph shows program level over the selected time period The level reflects the unit s peak weighted metering and although it does...

Страница 22: ...nge of interest NOTE The band scanning function mutes the receiver audio during the scan cycle and will put a glitch in the histograms as it actually tunes across the band and downloads data from each...

Страница 23: ...s been met alarm Alarm conditions must first be set up as described in the remainder of this section Following that the email SMS messaging and rear panel GPO tallies may be programmed These procedure...

Страница 24: ...squelched silenced during the alarm interval Mute On keeps random no carrier noise from making a nui sance of itself when the incoming signal is lost The RSSI dBuV grayed out bargraph gives the level...

Страница 25: ...entries on a num ber of the Web interface pages The specific items on the Setup page are discussed in order here Radio Settings NRSC is the default De Emphasis setting NRSC de emphasis is a truncated...

Страница 26: ...peaker icon at the top of each SOFIA 567 Web interface page which can be clicked on by as many as 10 users at the same time who have Internet access to the unit The streaming Format defaults to the po...

Страница 27: ...ungrounded when the alarm is received The other GPOs are programmed in identical fashion The Status line in this example shows that Output 1 is Inactive that is the assigned Audio Loss alarm has not...

Страница 28: ...ive in this instance Non Windows browsers may require you to enter the complete IP address of the unit which you can always find by front panel navigation to Setup Network IP Settings Incoming Interne...

Страница 29: ...ndard from the Audio En gineering Society specifies a 48kHz sample rate but Dante en coding can send at a 44 1kHz rate as well perhaps a more common rate in radio broadcast plants But with AES67 Enabl...

Страница 30: ...SNMP submenu default Mode setting is Disabled which in hibits communication between the SOFIA 567 and the SNMP Manager Changing Mode to Read Only allows the SOFIA 567 to be inter rogated by the SNMP...

Страница 31: ...mail under SMTP Settings You need to set up an actual email account the elements of which are just like setting up any con ventional email account Information to be entered here de pends on the provi...

Страница 32: ...d with this Recipient proceed to the next A Save command is not necessary in this operation TIME SETUP Time and DST The onboard Real Time Clock will re ceive updates from Internet Time daily and has s...

Страница 33: ...only trusted and authorized logged in users will be able to view those screens Once the password is saved no Web interface screen is accessi ble And on the front panel Now Playing will be the only sc...

Страница 34: ...rofile The entire SOFIA 567 setup may be saved to your computer as a small text file The Hardware Profile includes user settings alarm notification entries SNMP options etc and is useful for restoring...

Страница 35: ...fresh Hardware Profile as a firmware update may affect user settings If there is danger of compromising stored data the firmware update will include notes to that effect Updates are issued as small b...

Страница 36: ...34...

Страница 37: ...ion label has been removed or altered III TERMS OF WARRANTY Inovonics Inc products are warranted to be free from defects in materials and workmanship A Any discrepancies noted within THREE YEARS of th...

Страница 38: ......

Отзывы: