Model
RST/UVW
Grounding Wire
Screw
Recommend
ed Cable
(AWG/mil)
<2>
Recommend
ed Cable Lug
Recommend
ed Cable
(AWG/
kcmil)
<2>
Recommend
ed Cable Lug
T7
MD520‑4T30(B) (S)
1/0
TLK50‑8
3
TLK35‑8
M8
MD520‑4T37(B) (S)
3/0
TLK95‑10
1
TLK50‑8
M8
T8
MD520‑4T45(B) (S)
4/0
TLK120‑12
1/0
TLK70‑12
M12
MD520‑4T55(B) (S)
300
SQNBS180‑12
3/0
TLK95‑12
M12
MD520‑4T75(B) (S)
400
SQNBS250‑12
4/0
TLK120‑12
M12
T9
MD520‑4T90(S)
500
SQNBS250‑12
250
TLK300‑12
M12
MD520‑4T110(S)
2 x 250
SQNBS150‑12
250
SQNBS150‑12
M12
T10
MD520‑4T132(S)
2 x 300
TLK185‑12
300
TLK185‑12
M12
MD520‑4T160(S)
2 x 350
TLK185‑12
350
TLK185‑12
M12
T11
MD520‑4T200(S) (‑L)
2 x 350
TLK185‑12
350
TLK185‑12
M12
MD520‑4T220(S) (‑L)
2 x 500
SQNBS325‑16
500
SQNBS325‑16
M16
T12
MD520‑4T250(S) (‑L)
2 x 700
TLK400‑16
700
TLK400‑16
M16
MD520‑4T280(S) (‑L)
4 x 300
TLK185‑16
2 x 300
TLK185‑16
M16
MD520‑4T400(S) (‑L)
4 x 300
TLK185‑16
2 x 300
TLK185‑16
M16
Table 5–5 Cable selection (three phase 200‑240 V)
Structure
Model
RST/UVW
Grounding Wire
Screw
Recommend
ed Cable
(mm
2
)
<1>
Recommend
ed Cable Lug
Recommend
ed Cable
(mm
2
)
<1>
Recommend
ed Cable Lug
T1
MD520‑2T0.4B(S)
3 x 0.75
TNR0.75‑4
0.75
TNR0.75‑4
M4
MD520‑2T0.7B(S)
MD520‑2T1.1B(S)
MD520‑2T1.5B(S)
3 x 1
TNR1.25‑4
1
TNR1.25‑4
M4
T2
MD520‑2T2.2B(S)
3 x 1.5
TNR1.25‑4
1.5
TNR1.25‑4
M4
MD520‑2T3.7B(S)
3 x 2.5
TNR2‑4
2.5
TNR2‑4
M4
T3
MD520‑2T5.5B(S)
3 x 6
TNR5.5‑5
6
TNR5.5‑5
M5
T4
MD520‑2T7.5B(S)
3 x 10
TNR8‑5
10
TNR8‑5
M5
T5
MD520‑2T11(B)(S)
3 x 16
GTNR16‑6
16
GTNR16‑6
M6
T6
MD520‑2T15(B)(S)
3 x 16
GTNR16‑6
16
GTNR16‑6
M6
MD520‑2T18.5(B)(S)
3 x 25
GTNR25‑6
16
GTNR16‑6
M6
T7
MD520‑2T22(B)(S)
3 x 35
GTNR35‑8
16
GTNR16‑8
M8
MD520‑2T30(B)(S)
3 x 50
GTNR50‑8
25
GTNR25‑8
M8
T8
MD520‑2T37(B)(S)
3 x 70
GTNR70‑12
35
GTNR35‑12
M12
MD520‑2T45(S)
3 x 95
GTNR95‑12
50
GTNR50‑12
M12
MD520‑2T55(S)
3 x 120
GTNR120‑12
70
GTNR70‑12
M12
T9
MD520‑2T75(S)
2 x (3 x 95)
BC95‑12
95
BC95‑12
M12
Содержание MD520 Series
Страница 1: ......
Страница 16: ...Components 15 Figure 2 2 Components of T5 to T6 models...
Страница 19: ...Components 18 Figure 2 5 Components of T10 to T12 models with AC output reactor...
Страница 27: ...System Structure 26 Figure 3 9 Control circuit terminals...
Страница 43: ...Options 42 Figure 5 2 Dimensions of MD500 AZJ A1T2 through hole mounting bracket and holes mm...
Страница 44: ...Options 43 Figure 5 3 Dimensions of MD500 AZJ A1T3 through hole mounting bracket and holes mm...
Страница 45: ...Options 44 Figure 5 4 Dimensions of MD500 AZJ A1T4 through hole mounting bracket and holes mm...
Страница 46: ...Options 45 Figure 5 5 Dimensions of MD500 AZJ A1T5 through hole mounting bracket and holes mm...
Страница 47: ...Options 46 Figure 5 6 Dimensions of MD500 AZJ A1T6 through hole mounting bracket and holes mm...
Страница 49: ...Options 48 Figure 5 8 Dimensions of MD500 AZJ A1T8 through hole mounting bracket and holes mm...
Страница 54: ...Options 53 The following figures shows the installed copper busbar...
Страница 115: ...Options 114 Figure 5 48 Dimension drawing of ferrite clamp...
Страница 120: ...Expansion Cards 119 Figure 6 1 Installation position of expansion cards...