Chapter
4
Function
Code
Table
24
Function
Code
Parameter Name
Setting Range
Min. Unit
Default
Property
protection 1:
Enabled
F9-17 Reserved
-
1
0
☆
F9-18
1st fault type
1
0
☆
F9-19
2nd fault type
1
0
☆
F9-20
Latest fault type
0: No fault
1: Reserved
2: Overcurrent during
acceleration (Err02)
3: Overcurrent during
deceleration (Err03)
4: Overcurrent at
constant speed (Err04)
5: Overvoltage during
acceleration (Err05)
6: Overvoltage during
deceleration (Err06)
7: Overvoltage at
constant speed (Err07)
8: Reserved
9: Under-voltage (Err09)
10: Servo drive overload
(Err10)
11: Motor overload
(Err11)
12: Phase loss on input
side (Err12)
13: Phase loss on output
side (Err13)
14: Module overheat
(Err14)
15: External device fault
(Err15)
16: Communication fault
(Err16)
17: Contactor fault
(Err17)
18: Current detection
fault (Err18)
19: Motor auto-tuning
fault (Err19)
20: Reserved
21: Data overflow (Err21)
22: Reserved
23: Short circuit to ground
1 0
☆