background image

Wiring

-

22

-

Internal structure

Wiring of 8 high-speed DI and 4 high-speed DO terminals

Wiring of the external circuit

Содержание AC700 Series

Страница 1: ......

Страница 2: ...provides the installation wiring and operation instructions of the product More Documents Document Name Document Code Description Medium Sized PLC Programming Software User Guide 19010980 Describes th...

Страница 3: ...es that failure to comply with the notice may result in minor physical injury or damage to the equipment Safety Precautions Some drawings in this guide show the product without covers or protective gu...

Страница 4: ...e a sealed box for long distance transportation Never transport this product with equipment or materials that may damage or have negative impacts on this product Installation Only professional personn...

Страница 5: ...comply may result in product damage or even fire When connecting a drive with the motor ensure that the phase sequences of the drive and motor are consistent to prevent motor reverse rotation Ensure t...

Страница 6: ...product damage or fire Maintenance Do not allow non professionals to perform equipment installation wiring maintenance inspection or parts replacement Never perform maintenance during power on Failure...

Страница 7: ...worse damages physical injury or even death Make sure to re check the wiring and parameter setting after device replacement Disposal Scrap the equipment or product in accordance with relevant national...

Страница 8: ...del Number Nameplate Model number 1 Product Name A controller 3 Serial No First Digit 7 7 series 5 Operating System W Windows L Linux 2 Structure Type C booksize type 4 Hardware Configuration Code XX...

Страница 9: ...controller Intel J1900 4 GB memory 64 GB hard drive three USB 2 0 ports three network ports DP with display 16 axes AC702 01440300 Booksize controller Intel J1900 4 GB memory 64 GB hard drive three U...

Страница 10: ...2 0 ports 4 LAN port Not supported 5 LAN C port EtherCAT port 6 DP Display Port DP 7 I O communication port Eight DIs four DOs RS485 RS232 For details on the pins see section 4 3 8 Power terminal 24...

Страница 11: ...nguage LD ST SFC CFC Program execution mode Compile and run Compile and run Number of EtherCAT axes 16 axes 32 axes User program storage space 128 MB 128 MB User data storage space 128 MB 128 MB Ether...

Страница 12: ...lass A 2 Radiated emission Controller IEC61131 2 2017 IEC 61000 6 4 2018 Class A 3 ESD IEC61131 2 2017 IEC 61000 4 2 2008 6 kV contact discharge 8 kV air discharge 4 Radiated susceptibility RS IEC6113...

Страница 13: ...7 IEC 61000 4 5 2014 A1 2017 1 kV line to ground 11 Voltage dip and short interruption IEC 61000 4 29 2000 Voltage dip 40 UT and 70 UT duration 0 01s 0 03s 0 1s 0 3s 1s Duration for short interruption...

Страница 14: ...e for heat dissipation Exercise caution to avoid burns 3 1 2 Installation Environment When installing the controller on the guide rail take the operability maintainability and environment adaptation i...

Страница 15: ...Installation 14 3 2 Installation Instructions 3 2 1 Installation Dimensions The following figure shows the installation dimensions of the controller...

Страница 16: ...n 15 3 2 2 Installation Method Install and secure the AC700 with three screws at the torque of 1 2 N m through the rear earhook and the bottom stand Figure 3 1 Installing the controller through the re...

Страница 17: ...N m as shown below 1 Wing nut 2 Grounding cable 3 Grounding screw Figure 4 1 Grounding Grounding of shielded cables Communication cables must be shielded cables Ground the shielded cable as close to t...

Страница 18: ...gure below Figure 4 3 Required distances between different types of cables Note If two cables run parallel for an extended length increase the distance between the two cables accordingly You can also...

Страница 19: ...on site The following figure shows how to insert the power cable connector into the power input port Definition of the power input terminals Terminal No Name Type Function 1 Grounding Enclosure PE 2 0...

Страница 20: ...ort Definition Introduction to the I O Communication Port The I O communication port includes 22 pins terminals arranged in dual rows 11 pins per row and spaced at 3 5 mm It is used to transfer the DI...

Страница 21: ...High speed output 1 DO DO High speed output 2 Y2 21 22 Y3 High speed output 3 DO Note When the PLC crashes you can forcibly stop and restart the PLC program through the RUN STOP port To do so you need...

Страница 22: ...1 s OFF response time 1 s Isolation method Optocoupler isolation Short circuit proof output Yes RS485 communication specifications Item Specifications Number of channels 1 Baud rate bps 4 8 kbps 9 6 k...

Страница 23: ...Wiring 22 Internal structure Wiring of 8 high speed DI and 4 high speed DO terminals Wiring of the external circuit...

Страница 24: ...5 bus The 485 and 485 wires form a twisted pair A 120 termination resistor is attached to each end of the bus to prevent signal reflection All RS485 reference grounds are connected together Up to 128...

Страница 25: ...e RS485 bus If a branch cable is needed keep its length shorter than 3 m and as short as possible Star connection is strictly prohibited The following figure shows the commonly used bus topologies Dai...

Страница 26: ...le 1 Unshielded twisted pair cable with multiple conductors Connect one twisted pair to the 485 and 485 terminals and twist other wires together and connect them to the GND terminal 2 Recommended cabl...

Страница 27: ...ommunication port which does not support communication with InoProshop 3 LAN C EtherCAT master port 4 4 2 Ethernet Connection With the Ethernet port the controller can be connected point to point with...

Страница 28: ...Wiring 27 Figure 4 6 Connection between the PLC and other devices through a hub...

Страница 29: ...ifications Communication rate bps 10M 100M 1000M adaptive Network port indicators Indicator Function Color State Description A Link Act Yellow Steady off Disconnected Blinking Sending and receiving da...

Страница 30: ...per EtherCAT bus EtherCAT frame length 44 bytes to 1 498 bytes Process data Maximum 1 486 bytes per Ethernet frame Update time The update time is specified only in the EtherCAT bus design For the upd...

Страница 31: ...ing recommended specifications Item Specifications Cable type Flexible crossover cable S FTP Cat 5e Complied standards EIA TIA568A EN50173 ISO IEC11801 EIA TIA bulletin TSB EIA TIA SB40 A TSB36 Conduc...

Страница 32: ...unction 1 ML_Lane 0 p Lane 0 of the main link Differential signal 2 GND 3 ML_Lane 0 n Lane 0 of the main link Differential signal 4 ML_Lane 1 p Lane 1 of the main link Differential signal 5 GND 6 ML_L...

Страница 33: ...to 2 5 18 to 12 User signal cable Pin terminal 0 2 to 1 5 24 to 16 Grounding cable Tubular lug 2 14 to 15 Ethernet cable 4 7 2 Cable Preparation Requirements Cable with the pin terminal Preparation pr...

Страница 34: ...l into the terminal block and fix it with a screwdriver to a tightening torque not larger than 0 45 N m For the 2 11 pin dual row connector used for I O communication the terminal requirements are as...

Страница 35: ...Wiring 34 Category Terminal Size Length of Metal Part L2 Stripping Length Cord end with sheath crimping two wires 2 x 0 20 mm H0 5 16D 10 mm 12 mm 2 x 0 34 mm H0 5 16D 12 mm 15 mm...

Страница 36: ...the PLC to enter the operating mode If the programming port enp1s0 is set to a DHCP assigned address but no DHCP server or network connection is available it takes about 70 to 80 seconds for the PLC...

Страница 37: ...vices affected by the instantaneous power failure Take fail safe measures externally and monitor the power supply voltage on the external device side as necessary In addition take safety measures in t...

Страница 38: ...ed after power off judgment Item Content Processing Transferring the user program including online editing Interrupt The controller will be in NO APP mode at the next power on waiting for the user pro...

Страница 39: ...m operation warning Error indicator ERR ON Red App system error Running status indicator RUN Blinking The device is being identified ON Green The app is running System identification indicator Blinkin...

Страница 40: ...a desktop or portable PC meeting the following requirements 1 OS Windows 7 or 10 64 bit is recommended 2 Memory 4 GB or above 3 Hard drive free space of 5 GB or above Connect the PC and AC700 control...

Страница 41: ...version of InoProShop and restart the computer Installing InoProShop Go to the Windows System Resource Manager open the directory where the installation files are located and double click the InoProS...

Страница 42: ...Programming Tool and Download 41 Step Description Screen 4 Select components that you want to install and click Next 5 Click Next...

Страница 43: ...rd Complete window appears and click Finish to complete the installation Setting the language The default interface language of InoProShop is Simplified Chinese If you need to change the language choo...

Страница 44: ...Programming Tool and Download 43...

Страница 45: ...to 55 C Use a thermometer to measure the ambient temperature and control the ambient temperature within 0 C to 55 C Check that the ambient humidity is suitable when the controller is in a cabinet the...

Страница 46: ...ervice life expires replace the battery whether it can run normally or not For the replacement method see 7 2 Installation and Removal of the Battery on page 45 7 2 Installation and Removal of the Bat...

Страница 47: ...e battery is being discharged the clock will stop timing and the CMOS data will be lost when the power is off Battery life and replacement interval The actual service life of the battery is related to...

Страница 48: ...B flash disk Remove the USB flash disk only after the automatic restart following the update If you remove the USB flash disk before countdown the upgrade does not start The firmware upgrade starts af...

Страница 49: ...88 and that of LAN B port is 192 168 2 88 1 Format the USB flash disk to FAT32 or NTFS and create an empty file network default in the root directory of the USB flash disk 2 Insert the USB flash disk...

Страница 50: ...XE IPL is started 0x60 DXE Core is started 0x61 NVRAM initialization 0x62 Installation of the South Bridge Runtime Services 0x69 North Bridge DXE initialization is started 0x70 South Bridge DXE initia...

Страница 51: ...U cache error 0x59 CPU micro code is not found or micro code update is failed 0x5A Internal CPU error 0x5B reset PPI is not available 0x5C PEI phase BMC self test failure 0xAB Setup Input Wait 0xD0 CP...

Страница 52: ...Modbus RTU1 Slave address setting error 0x81 Modbus RTU1 Frame length error 0x82 Modbus RTU1 Illegal data address 0x83 Modbus RTU1 CRC check failed 0x84 Modbus RTU1 Illegal function 0x85 Modbus RTU1 C...

Страница 53: ...ddr Revision Number does not match try to continue E09 1 Address addr ProductID does not match All stopped 2 Address addr ProductID ProductID does not match try to continue E0A Read of product or vend...

Страница 54: ...le Time too small E94 Invalid DC SYNCH Configuration E95 Invalid DC Latch Configuration E96 PLL Error E97 Invalid DC IO Error E98 Invalid DC Timeout Error E99 DC invalid Sync Cycle Time E9A DC Sync0 C...

Страница 55: ...PS00004465A00...

Отзывы: