background image

Version 1.4  

 

 

 

                              Page 9 

min/max

 

mode.

 

The

 

minimum

 

water

 

temperature

 

and

 

indoor

 

temperature

 

will

 

be

 

displayed.

 

Press

 

the

 

CLEAR

 

button

 

(on

 

the

 

top

 

of

 

the

 

display)

 

to

 

clear

 

the

 

minimum

 

values

 

to

 

the

 

current

 

measured

 

values.

 

2.

 

Maximum

 

Values

.

 

Press

 

the

 

MIN/MAX

 

button

 

again,

 

and

 

the

 

maximum

 

water

 

temperature

 

and

 

indoor

 

temperature

 

will

 

be

 

displayed.

 

Press

 

the

 

CLEAR

 

button

 

(on

 

the

 

top

 

of

 

the

 

display)

 

to

 

clear

 

the

 

maximum

 

values

 

to

 

the

 

current

 

measured

 

values.

 

3.

 

Press

 

the

 

MIN/MAX

 

button

 

again

 

to

 

exit

 

the

 

min/max

 

mode.

 

 

4.5

 

°C/°F

 

Units

 

of

 

Measure

 

To

 

toggle

 

between

 

°C/°F

 

temperature

 

units

 

of

 

measure

 

on

 

the

 

display,

 

press

 

the

 

C/F

 

button

 

on

 

the

 

back

 

of

 

the

 

display.

 

4.6

 

Multi

Channel

 

Operation

 

The

 

station

 

supports

 

up

 

to

 

3

 

remote

 

thermometers

 

(one

 

is

 

included).

 

The

 

optional

 

sensors

 

can

 

be

 

purchased

 

at

 

Inovalley.

 

4.6.1

 

Multi

channel

 

Sensor

 

Initialization

 

Place

 

the

 

multiple

 

remote

 

sensors

 

about

 

10

 

feet

 

from

 

the

 

console.

 

Power

 

up

 

the

 

sensors

 

and

 

console

 

in

 

the

 

following

 

order:

 

1.

 

Power

 

up

 

the

 

first

 

remote

 

thermometer

 

and

 

set

 

the

 

channel

 

number

 

dip

 

switches,

 

as

 

described

 

in

 

Section

 

2.3.

 

Verify

 

the

 

display

 

reads

 

Channel

 

1.

   

2.

 

Power

 

up

 

the

 

second

 

remote

 

thermometer

 

and

 

set

 

the

 

channel

 

number

 

dip

 

switches,

 

as

 

described

 

in

 

Section

 

2.3.

 

Verify

 

the

 

display

 

reads

 

Channel

 

2.

   

3.

 

Power

 

up

 

the

 

third

 

remote

 

thermometer

 

(if

 

available)

 

and

 

set

 

the

 

channel

 

number

 

dip

 

switches,

 

as

 

described

 

in

 

Section

 

2.3.

 

Verify

 

the

 

display

 

reads

 

Channel

 

3.

 

4.

 

Power

 

up

 

the

 

console

 

last

 

and

 

wait

 

about

 

3

 

minutes.

 

Press

 

the

 

CHANNEL

 

button

 

on

 

the

 

top

 

of

 

the

 

display

 

to

 

verify

 

all

 

three

 

sensors

 

are

 

communicating

 

to

 

the

 

console.

   

5.

 

Once

 

verified,

 

you

 

are

 

ready

 

to

 

install

 

the

 

remote

 

thermometers.

 

4.6.2

 

Multi

channel

 

Sensor

 

Accuracy

 

Note

 

Verify

 

the

 

temperature

 

values

 

match

 

closely

 

with

 

the

 

console

 

and

 

sensor

 

array

 

in

 

the

 

same

 

location.

 

The

 

sensors

 

should

 

be

 

within

 

4°F

 

(the

 

accuracy

 

is

 

±

 

2°F).

 

 

Allow

 

about

 

30

 

minutes

 

for

 

all

 

sensors

 

to

 

stabilize.

 

4.7

 

Maintenance

 

We

 

recommend

 

inspecting

 

the

 

gasket

 

inside

 

the

 

lid

 

of

 

the

 

floating

 

thermometer

 

with

 

each

 

battery

 

change.

 

Moisten

 

with

 

pool

 

gasket

 

lubricant

 

available

 

from

 

most

 

pool

 

stores.

 

Inspect

 

for

 

any

 

moisture

 

inside

 

the

 

floating

 

thermometer.

 

Replace

 

the

 

gasket

 

every

 

1

 

year

 

.

 

To

 

replace

 

the

 

gasket,

 

slide

 

the

 

gasket

 

over

 

the

 

float

 

potion

 

of

 

the

 

floating

 

thermometer

 

and

 

insert

 

into

 

the

 

gasket

 

guide

 

on

 

the

 

lid.

 

 

5.

 

GLOSSARY

 

OF

 

TERMS

 

Term

 

Definition

Accuracy

 

Accuracy

 

is

 

defined

 

as

 

the

 

ability

 

of

 

a

 

measurement

 

to

 

match

 

the

 

actual

 

Содержание SP03

Страница 1: ...Version 1 4 Page 1 WIRELESS POOL THERMOMETER Ref SP03 User s manual ...

Страница 2: ... Time 8 4 2 3 Set Date 8 4 3 Alarm Mode 8 4 3 1 Activating Deactivating the Alarm 8 4 3 2 Cancelling the Alarm 8 4 3 3 Snooze Alarm 8 4 4 Min Max Mode 8 4 5 C F Units of Measure 9 4 6 Multi Channel Operation 9 4 6 1 Multi channel Sensor Initialization 9 4 6 2 Multi channel Sensor Accuracy Note 9 4 7 Maintenance 9 5 GLOSSARY OF TERMS 9 6 SPECIFICATIONS 10 6 1 Wireless Specifications 10 6 2 Measurem...

Страница 3: ...e Wireless Poo Thermometer consists of a display station receiver and a wireless thermometer remote transmitter 2 1 Parts List QTY Item 1 Display station Dimensions 119x74x21mm 1 Pool Thermometer transmitter Dimensions ø80mmx160mm 1 User Manual 2 2 Remote Pool Thermometer Sensor Set Up Note To avoid permanent damage please take note of the battery polarity before inserting the batteries 1 Twist of...

Страница 4: ...nge Dip Switches 1 and 2 as referenced in Table 1 5 Temperature Units of Measure To choose the transmitter display units of measure F C change Dip Switch 3 as referenced in Table 1 DIP SWITCH FUNCTION 1 2 3 DOWN DOWN Channel 1 factory default setting UP DOWN Channel 2 DOWN UP Channel 3 DOWN F UP C factory default setting Table 1 6 Verify the correct channel number CH and temperature units of measu...

Страница 5: ... 1 5V alkaline or lithium avoid rechargeable batteries in the back of the display console All of the LCD segments will light up for a few seconds to verify all segments are operating properly and the unit will beep Replace the battery door and fold out the desk stand and place the console in the upright position The console will instantly display indoor temperature and the default date and time Th...

Страница 6: ...Layout Note The following illustration shows the full segments of the receiver LCD for description purposes only and will not appear like this during normal operation Figure8 1 Transmitter channel number 2 Water temperature units F C 3 Water temperature 4 Indoor temperature units F C 5 Indoor temperature 6 Time and snooze alarm 7 Time of day 8 Date 9 Day of week 10 Min max icon 11 Transmitter rece...

Страница 7: ...ing buttons and location 1 MODE on the back of the display 2 C F on the back of the display 3 MAX MIN on the back of the display 4 SET on the back of the display 5 CHANNEL on the top of the display 6 CLEAR on the top of the display 4 2 Set Program Mode Press the MODE button to switch between TIME ALARM DATE The following section defines how to set the time alarm and date Notes After 60 seconds of ...

Страница 8: ... the day 4 Press the SET button again to return to normal mode 4 3 Alarm Mode 4 3 1 Activating Deactivating the Alarm 1 While in the ALARM mode press the C F button to activate the alarm The alarm icon will appear 2 Press the C F button again to deactivate the alarm The alarm icon will disappear 4 3 2 Cancelling the Alarm When an alarm has been triggered the alarm will sound and the alarm icon wil...

Страница 9: ...wer up the second remote thermometer and set the channel number dip switches as described in Section 2 3 Verify the display reads Channel 2 3 Power up the third remote thermometer if available and set the channel number dip switches as described in Section 2 3 Verify the display reads Channel 3 4 Power up the console last and wait about 3 minutes Press the CHANNEL button on the top of the display ...

Страница 10: ...nths for base station Minimum 12 months for remote thermometer sensor use lithium batteries in cold water climates 7 TROUBLESHOOTING GUIDE Problem Solution Wireless remote not reporting in to station The maximum line of sight communication range is 100m Move the display console closer to the remote sensor Cycle power on the station by removing and re inserting the batteries The station may have ex...

Страница 11: ... alkaline batteries that last longer than the saline batteries and when possible rechargeable batteries deposit batteries and accumulators in specific containers arranged among traders For example metals will be valued and polluted the environment because they contain heavy metals hazardous to health and the environment primarily cadmium and nickel The piles must installation by respecting the pol...

Страница 12: ... 12 instructions are complied with or to make himself the replacement of batteries If a battery is swallowed immediately consult a doctor or poison control center nearest you Do not forget to carry the product with you ...