
2
INSTALLATION
12
INOR TRANSMITTERS
www.inor.com
07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
2.10 Installation and control drawing
This drawing is property of Inor Process AB, Malmö, Sweden, without whose permission
it may not be copied, and the contents thereof must not be imparted to third party nor be
Scale:
Revision
Det.no.
Date
Comment
File
Date:
Description
Quantity
Document-ID
Drawing
number:
General
tolerance
General
surface
roughness
Ra
SS-ISO-2768-1
m
Approved
by:
Designed
b
y:
Approved
by:
Title:
Rev:
used for any unautherized purpose. Contravention will be prosecuted.
No
of
sheets:
Sheet:
Treatment:
Projection:
Material
Article
no.
Ra
3,2
1:1
2018-06-21
NH
GP
4006801801_1.dwg
1
1
4006801801
1
180
716
First
release
revision
GP
Rev
1
Europe:
KIWA
16ATEX0011
X
IECEx
KIWA
16.0005X
CE
0539
II
(1)
G
[Ex
ia
Ga]
IIC
Non
H
azardous
Location
(Safe
area)
Europe:
1.
The
associated
apparatus
or
intrincically
safe
equipment
shall
be
approved.
2.
Safety
barriers
must
b
e
installed
in
a
ccordance
with
the
manufacturers
instructions.
3.
If
the
cable
parameters
are
unknown,
the
following
values
may
be
used
as
a
guideline:
Capacitance
=
200
pF/m
Inductance
=
0.66
μH/m
4.
If
a
safety
barrier
is
used
and
the
safety
barrier
requires
an
earth
conection
then
the
resistance
b
etween
the
terminal
on
the
safety
barrier
and
the
earth
ground
shall
be
less
than
1
ohm.
5.
Do
not
connect
any
communication
equipment
to
the
communication
port
of
the
transmitter
unless
area
is
known
to
b
e
non-hazardous.
North
America:
1.
The
configuration
of
the
associated
apparatus
or
intrincically
safe
equipment
or
simple
apparatus
shall
be
approved.
2.
Safety
barriers
must
b
e
installed
in
a
ccordance
with
the
manufacturers
instructions.
3.
Installation
must
be
accordance
w
ith
the
National
Electrical
Code
(NFPA
70,
Article
500
to
510),
Canadian
Electrical
Code
(CEC)
Section
18
and
ANSI/ISA-RP12.06.01
4.
If
the
cable
parameters
are
unknown,
the
following
values
shall
be
used:
Capacitance
=
200
pF/m
(60pF/feet)
Inductance
=
0.66
μH/m
(0.20μH/feet)
5.
If
the
safety
barrier
requires
an
earth
conection
then
the
resistance
b
etween
the
terminal
on
the
safety
barrier
and
the
earth
ground
shall
be
less
than
1
ohm.
6.
Do
not
connect
any
communication
equipment
to
the
communication
port
of
the
transmitter
unless
area
is
known
to
b
e
non-hazardous.
The
control
e
quipment
connected
must
not
use
o
r
g
enerate
over
250
V
rms
or
dc
Um
=
250
V
Ex-document,
may
not
be
revised
without
approval
from
the
C
ertification
Body.
1000457600
4006801801
SWEDEN
Doc.
type:
ZZ
USB
Connection
(to
P
C)
U
m=2
5
0V5
0/6
0H
z
Transmitter
Connection
ATEX,
IECEx
and
FM
Uo=Voc=9.4
V
Io=Isc=96
mA
Po=680
mW
Group
Co=Ca
Lo=La
(μF)
(mH)
IIC
A/B
1
1
IIB
C
2
9
2
9
IIA
D
300
70
Installation
and
control
drawing
Transmitter
configuration
kit
ICON-X
configuration
kit
Specific
conditions
of
use:
-
The
transmitter's
communication
port
(USB
connection)
may
only
be
connected
to
the
certified
ICON-X
interface.
When
the
ICON-X
is
connected,
the
temperature
transmitter
shall
be
outside
of
the
hazardous
area;
a
connected
sensor
may
be
located
in
the
hazardous
area.
-
F
or
the
applicable
ambient
temperature
range,
see
the
sketch.
21
+
22
-
1
2
3
4
North
America:
USA
FM
18
US0117X
Canada
FM
18
CA0056X
AIS
Class
I,
Di
vision
1,
Division
2,
Groups
A,
B,
C,
D;
Class
I,
Zo
ne
0,
Zone
1,
Zone
2
[AEx
/
Ex
ia
Ga
]
IIC
ICON-X
configuration
kit
Power
supply/4-20
mA,
2-Wire
loop
(-)
(+)
ENTITY
P
ARAMETERS
Voc=Uo
≥
30
V
Isc=Io
≥
100
mA
Po
≥
0.9
W
Ca=Co
Ci
+
Ccable
La=Lo
Li
+
Lcable
Associated
apparatus
0°
C≥T
a≥+
5
0°
C
Hazardous
(Classified)
Location
1
4
3
2
6
7
Sensor
(RTD,T
/Cetc.)
5
+
-
Sensor
(RTD,
T
/C
etc.)
The
topside
The
bottom
side
(Power
supply
is
optional
for
configuration
with
ICON-X)
Содержание ICON-X
Страница 13: ...NOTES 3 13 INOR TRANSMITTERS www inor com 07 2018 4006932901 AD ICON X ConSoft R01 en...
Страница 14: ...3 NOTES 14 INOR TRANSMITTERS www inor com 07 2018 4006932901 AD ICON X ConSoft R01 en...
Страница 15: ...NOTES 3 15 INOR TRANSMITTERS www inor com 07 2018 4006932901 AD ICON X ConSoft R01 en...