INOR ICON-X Скачать руководство пользователя страница 12

2

 INSTALLATION 

12 

INOR TRANSMITTERS

www.inor.com

07/2018 - 4006932901 - AD ICON-X ConSoft R01 en

2.10  Installation and control drawing

This drawing is property of Inor Process AB, Malmö, Sweden, without whose permission
it may not be copied, and the contents thereof must not be imparted to third party nor be

Scale:

Revision

Det.no.

Date

Comment

File

Date:

Description

Quantity

Document-ID

Drawing

number:

General

tolerance

General

surface

roughness

Ra

SS-ISO-2768-1

m

Approved

by:

Designed

b

y:

Approved

by:

Title:

Rev:

used for any unautherized purpose. Contravention will be prosecuted.

No

of
sheets:

Sheet:

Treatment:

Projection:

Material

Article

no.

Ra

3,2

1:1

2018-06-21

NH

GP

4006801801_1.dwg

1

1

4006801801

1

180

716

First

release

revision

GP

Rev

1

Europe:

KIWA

16ATEX0011

X

IECEx

KIWA

16.0005X

CE

0539

II
(1)

G
[Ex

ia
Ga]

IIC

Non

H

azardous

Location

(Safe

area)

Europe:

1.
The

associated

apparatus

or
intrincically

safe

equipment

shall

be
approved.

2.
Safety

barriers

must

b

e

installed

in

a

ccordance

with

the

manufacturers

instructions.

3.
If
the

cable

parameters

are

unknown,

the

following

values

may

be

used

as
a

guideline:

Capacitance

=
200

pF/m

Inductance

=
0.66

μH/m

4.
If
a

safety

barrier

is
used

and

the

safety

barrier

requires

an
earth

conection

then

the

resistance

b

etween

the

terminal

on
the

safety

barrier

and

the

earth

ground

shall

be
less

than

1

ohm.

5.
Do

not

connect

any

communication

equipment

to
the

communication

port

of
the

transmitter

unless

area

is
known

to
b

e

non-hazardous.

North

America:

1.
The

configuration

of
the

associated

apparatus

or
intrincically

safe

equipment

or
simple

apparatus

shall

be
approved.

2.
Safety

barriers

must

b

e

installed

in

a

ccordance

with

the

manufacturers

instructions.

3.
Installation

must

be
accordance

w

ith
the
National

Electrical

Code

(NFPA

70,

Article

500

to
510),

Canadian

Electrical

Code

(CEC)

Section

18
and

ANSI/ISA-RP12.06.01

4.
If
the

cable

parameters

are

unknown,

the

following

values

shall

be

used:

Capacitance

=
200

pF/m

(60pF/feet)

Inductance

=
0.66

μH/m

(0.20μH/feet)

5.
If
the

safety

barrier

requires

an
earth

conection

then

the

resistance

b

etween

the

terminal

on
the

safety

barrier

and

the

earth

ground

shall

be
less

than

1

ohm.

6.
Do

not

connect

any

communication

equipment

to
the

communication

port

of
the

transmitter

unless

area

is
known

to
b

e

non-hazardous.

The

control

e

quipment

connected

must

not

use

o

r

g

enerate

over

250

V

rms
or
dc

Um

=
250

V

Ex-document,

may

not

be
revised

without

approval

from

the

C

ertification

Body.

1000457600

4006801801

SWEDEN

Doc.

type:

ZZ

USB

Connection

(to

P

C)

U

m=2

5

0V5

0/6

0H

z

Transmitter

Connection

ATEX,

IECEx

and

FM

Uo=Voc=9.4

V

Io=Isc=96

mA

Po=680

mW

Group

Co=Ca

Lo=La

(μF)

(mH)

IIC

A/B

1

1

IIB

C

2

9

2

9

IIA

D

300

70

Installation

and

control

drawing

Transmitter

configuration

kit

ICON-X

configuration

kit

Specific

conditions

of
use:

-

The

transmitter's

communication

port

(USB

connection)

may

only

be

connected

to
the

certified

ICON-X

interface.

When

the

ICON-X

is
connected,

the

temperature

transmitter

shall

be

outside

of
the

hazardous

area;

a

connected

sensor

may

be
located

in

the

hazardous

area.

-

F

or
the

applicable

ambient

temperature

range,

see

the

sketch.

21
+

22
-

1

2

3

4

North

 

America:

USA

 

FM

18

US0117X

Canada

 

FM

18

CA0056X

AIS

 

Class

 

I,

 

Di

vision

 

1,

 

Division

 

2,

 

Groups

 

A,

 

B,

 

C,

 

D;

 

Class

 

I,

 

Zo
ne

 

0,

 

Zone

 

1,

 

Zone

 

2

 

[AEx

 

/

 

Ex

 

ia

 

Ga
]

 

IIC

ICON-X

configuration

kit

Power

supply/4-20

mA,

2-Wire

loop

(-)

(+)

ENTITY

P

ARAMETERS

Voc=Uo


30
V

Isc=Io


100

mA

Po

0.9

W

Ca=Co


Ci
+
Ccable

La=Lo


Li
+
Lcable

Associated

apparatus


C≥T

a≥+

5


C

Hazardous

(Classified)

Location

1

4

3

2

6

7

Sensor

(RTD,T

/Cetc.)

5

+

-

Sensor

(RTD,

T

/C
etc.)

The

topside

The

bottom

side

(Power

supply

is
optional

for

configuration

with

ICON-X)

Содержание ICON-X

Страница 1: ...ace ICON X Transmitter configuration kit INOR TRANSMITTERS INOR TRANSMITTERS INOR TRANSMITTERS INOR TRANSMITTERS Supplementary Instructions Supplementary Instructions Supplementary Instructions Supple...

Страница 2: ...cal data 5 2 Installation 6 2 1 General safety notes 6 2 2 Safety Diagram 6 2 3 Installation of USB interface drivers 6 2 4 Installation of configuration software ConSoft 7 2 5 Description of USB inte...

Страница 3: ...X directive 2014 34 EU based on the harmonised standards EN 60079 0 2012 including A11 and EN 60079 11 2012 and the ROHS directive 2011 65 EU based on the harmonised standard EN 50581 2012 For more in...

Страница 4: ...very 1 USB communication cable connection between PC and USB interface 2 USB interface 3 Mini USB to Mini USB adapter USB interface to transmitter 4 Mini USB to four pole rectangular connector USB Int...

Страница 5: ...ngth 114 mm 4 49 width 36 mm 1 42 heigth 26 mm 1 02 Electrical connection Power supply PC s USB port 5 VDC 74 mA max Galvanic isolation 1500 VAC Input PC to USB interface USB cable type A to type B Ou...

Страница 6: ...to section Installation guide for ConSoft and USB Interface drivers All software USB drivers and installation guides can also be downloaded from the website CAUTION The USB interface ICON X is an Ex...

Страница 7: ...itter easier Their functions are described below USB LED indicates data transfer It lights during data transfer otherwise it is off PC LED indicates connection between configuration program and PC It...

Страница 8: ...USB interface Error message USB Interface s hardware and or software should be updated appears in ConSoft Contact us for update of your USB interface Error message Unable to install because a newer ve...

Страница 9: ...of USB configuration kit ICON X Figure 2 1 Item No Item Name Weight g Weight lb 1 USB communication cable connection between PC and USB interface ICON X 42 0 09 2 USB Interface ICON X 63 0 14 3 Mini U...

Страница 10: ...CAUTION Before disassembling the device make sure you have the proper tools needed Torx Screwdriver T9 Philips head Screwdriver 1 Item No Item Name Weight g Weight lb 1 Label upper side polyester 0 0...

Страница 11: ...ted 3 Remove the labels polyester and polyethylene sorted as plastic 4 By unscrewing of the two threaded screws item 5 from the bottom cover of the housing upper part of Item 3 in Table 2 can be separ...

Страница 12: ...must be accordance with the National Electrical Code NFPA 70 Article 500 to 510 Canadian Electrical Code CEC Section 18 and ANSI ISA RP12 06 01 4 If the cable parameters are unknown the following val...

Страница 13: ...NOTES 3 13 INOR TRANSMITTERS www inor com 07 2018 4006932901 AD ICON X ConSoft R01 en...

Страница 14: ...3 NOTES 14 INOR TRANSMITTERS www inor com 07 2018 4006932901 AD ICON X ConSoft R01 en...

Страница 15: ...NOTES 3 15 INOR TRANSMITTERS www inor com 07 2018 4006932901 AD ICON X ConSoft R01 en...

Страница 16: ...2 2 E mail info inor gmbh de Web www inor gmbh de The current list of all INOR contacts and addresses can be found at www inor com Inor Process AB PO Box 9125 SE 200 39 Malm Sweden Phone 46 0 40 312 5...

Отзывы: