APPENDIX
8
55
IPAQ C330/R330
www.inor.com
01/2019 - 4007317401 – MA IPAQ 330 R01 en
This drawing is property of Inor Process AB, Malmö, Sweden, without whose permission
it may not be copied, and the contents thereof must not be imparted to third party nor be
Scale:
Revision
Det.no.
Date
Comment
File
Date:
Description
Quantity
Document-ID
Drawing
number:
General
tolerance
General
surface
roughness
Ra
SS-ISO-2768-1
m
Approved
by:
Designed
b
y:
Approved
by:
Title:
Rev:
used for any unautherized purpose. Contravention will be prosecuted.
No
of
sheets:
Sheet:
Treatment:
Projection:
Material
Article
no.
Ra
3,2
1:1
Installation
and
control
d
rawing
IPAQ
R330X
Temperature
transmitter
2016-11-23
LH
GP
4005499601_3.dwg
1
1
4005499601
3
161123
First
release
revision
GP
Rev
1
Europe:
KIWA
16ATEX0040
X
IECEx
KIWA
16.0018X
CE
0539
II
1
G
Ex
ia
IIC
T6...T4
Ga
T4:
-40
°C
≥
T
a
≥
+85
°C
T5:
-40
°C
≥
T
a
≥
+75
°C
T6:
-40
°C
≥
T
a
≥
+60
°C
North
America:
USA
F
M17US0283X
IS
Class
I,
D
ivision
1,
Groups
A,
B,
C,
D;
T4
to
T6
Class
I,
Z
one
0,
AEx
ia
IIC
Ga
T4
to
T6
Canada
FM17CA0144X
Class
I,
D
ivision
1,
Groups
A,
B,
C,
D;
T4
to
T6
Class
I,
Z
one
0,
Ex
ia
IIC
Ga
T4
to
T6
T4:
-40
°C
≥
T
a
≥
+85
°C
-40
°F
≥
Ta
≥
+185
°F
T5:
-40
°C
≥
T
a
≥
+75
°C
-40
°F
≥
Ta
≥
+167
°F
T6:
-40
°C
≥
T
a
≥
+60
°C
-40
°F
≥
Ta
≥
+140
°F
Non
H
azardous
Location
(Safe
a
rea)
Ui=Vmax=30
V
Ii=Imax:100
mA
Pi=Pmax=900
mW
Ci
=
23.1
nF
L
i=2
0μ
H
(-)
(+)
Power
supply
/
4
-20
m
A
2-Wire
loop
ENTITY
P
ARAMETERS
Voc=Uo
≥
3
0
V
Isc=Io
≥
100
mA
Po
≥
0.9
W
Ca=Co
C
i
+
C
cable
La=Lo
L
i
+
L
cable
Europe:
1.
The
associated
apparatus
or
intrincically
safe
equipment
shall
be
approved.
2.
Safety
barriers
must
b
e
installed
in
a
ccordance
w
ith
the
manufacturers
instructions.
3.
If
the
cable
parameters
are
unknown,
the
following
values
may
be
used
as
a
guideline:
Capacitance
=
200
pF/m
Inductance
=
0.66
μH/m
4.
If
a
safety
barrier
is
used
and
the
safety
barrier
requires
an
earth
conection
then
the
resistance
b
etween
the
terminal
on
the
safety
barrier
and
the
e
arth
ground
shall
be
less
than
1
ohm.
5.
Do
not
connect
any
communication
equipment
to
the
communication
port
of
the
transmitter
unless
area
is
known
to
b
e
non-hazardous.
North
America:
1.
The
configuration
of
the
a
ssociated
apparatus
or
intrincically
safe
equipment
or
simple
apparatus
shall
be
approved.
2.
Safety
barriers
must
b
e
installed
in
a
ccordance
w
ith
the
manufacturers
instructions.
3.
Installation
must
b
e
a
ccordance
w
ith
the
National
Electrical
Code
(NFPA
70,
Article
500
to
510),
Canadian
Electrical
Code
(CEC)
Section
18
and
ANSI/ISA-RP12.06.01
4.
If
the
cable
parameters
are
unknown,
the
following
values
shall
be
used:
Capacitance
=
200
pF/m
(60pF/feet)
Inductance
=
0.66
μH/m
(0.20μH/feet)
5.
If
the
safety
barrier
requires
an
earth
conection
then
the
resistance
b
etween
the
terminal
on
the
safety
barrier
and
the
e
arth
ground
shall
be
less
than
1
ohm.
6.
Do
not
connect
any
communication
equipment
to
the
communication
port
of
the
transmitter
unless
area
is
known
to
b
e
non-hazardous.
Associated
apparatus
The
control
e
quipment
connected
must
not
use
o
r
g
enerate
over
250
V
rms
or
dc
Um
=
250
V
IPAQ
R
330X
21
+
22
-
1
2
3
4
Ex-document,
may
not
be
revised
without
approval
from
the
C
ertification
Body.
Uo=Voc=30
V
Io=Isc=54
mA
Po=405
mW
Group
Co=Ca
Lo=La
(nF)
(mH)
IIC
A/B
38.1
11
IIB
C
530
45
IIA
D
1000
90
Sensor
(RTD,
T
/C
etc.)
1000375907
4005499601
SWEDEN
Doc.
type:
ZZ
Specific
conditions
of
use:
-
The
transmitter's
communication
port
(USB
connection)
may
only
be
connected
to
the
certified
ICON-X
communication
interface.
When
the
ICON-X
is
connected,
the
temperature
transmitter
shall
be
outside
of
the
hazardous
area,
a
connected
sensor
may
be
located
in
the
hazardous
area.
-
F
or
the
applicable
ambient
temperature
range,
see
the
sketch.
-
The
transmitter
shall
be
mounted
into
a
suitable
enclosure
that
provides
a
degree
of
protection
of
at
least
IP20.
USB
Connection
Europe:
KIWA
16ATEX0040
X
IECEx
KIWA
16.0018X
CE
0539
II
1
G
Ex
ia
IIC
T6...T4
Ga
T4:
-40
°C
≥
T
a
≥
+85
°C
T5:
-40
°C
≥
T
a
≥
+75
°C
T6:
-40
°C
≥
T
a
≥
+60
°C
Non
H
azardous
Location
(Safe
a
rea)
Ui=Vmax=30
V
Ii=Imax:100
mA
Pi=Pmax=900
mW
Ci
=
23.1
nF
L
i=2
0μ
H
(-)
(+)
Power
supply
/
4
-20
m
A
2-Wire
loop
ENTITY
P
ARAMETERS
Voc=Uo
≥
3
0
V
Isc=Io
≥
100
mA
Po
≥
0.9
W
Ca=Co
C
i
+
C
cable
La=Lo
L
i
+
L
cable
Associated
apparatus
The
control
e
quipment
connected
must
not
use
o
r
g
enerate
over
250
V
rms
or
dc
Um
=
250
V
IPAQ
R
330X
21
+
22
-
1
2
3
4
Sensor
(RTD,
T
/C
etc.)
USB
Connection
Hazardous
(Classified)
Location
Rev
2
170120
Changed
v
alue
for
C
o
GP
Rev
3
180615
cFMus
added,
Co
group
IIA=1000
nF
GP
North
America:
USA
F
M17US0283X
IS
Class
I,
D
ivision
1,
Groups
A,
B,
C,
D;
T4
to
T6
Class
I,
Z
one
0,
AEx
ia
IIC
Ga
T4
to
T6
Canada
FM17CA0144X
Class
I,
D
ivision
1,
Groups
A,
B,
C,
D;
T4
to
T6
Class
I,
Z
one
0,
Ex
ia
IIC
Ga
T4
to
T6
T4:
-40
°C
≥
T
a
≥
+85
°C
-40
°F
≥
Ta
≥
+185
°F
T5:
-40
°C
≥
T
a
≥
+75
°C
-40
°F
≥
Ta
≥
+167
°F
T6:
-40
°C
≥
T
a
≥
+60
°C
-40
°F
≥
Ta
≥
+140
°F
ATEX,
IECEx
and
cFMus
Uo=Voc=30
V
Io=Isc=54
mA
Po=405
mW
Group
Co=Ca
Lo=La
(nF)
(mH)
IIC
A/B
38.1
11
IIB
C
530
45
IIA
D
1000
90
Hazardous
(Classified)
Location
Содержание 70C330X010
Страница 2: ...2 www inor com 01 2019 4007317401 MA IPAQ 330 R01 en IMPRINT...
Страница 56: ...9 NOTES 56 IPAQ C330 R330 www inor com 01 2019 4007317401 MA IPAQ 330 R01 en...
Страница 57: ...NOTES 9 57 IPAQ C330 R330 www inor com 01 2019 4007317401 MA IPAQ 330 R01 en...
Страница 58: ...9 NOTES 58 IPAQ C330 R330 www inor com 01 2019 4007317401 MA IPAQ 330 R01 en...