4
Document Name : OIM V 1.0 Page 4 of 7
View List :-
1) To access the View List press & release ‘SHIFT’ key Once.
5
Total Batch Count will be shown here. Press Reset Key for 3 Sec to Reset Batch
Count.
Batch View :-
This parameter will appears only if OP2 is selected as Batch Mode.
Batch
View
Description
Default
Parameter
Lower
Display
Upper
Display
Programming as Timer Mode
Configuration List :-
1) To Enter in this mode Press & Hold ‘SET’ key for 5 sec. at Power On. ‘CNFG’ & ‘V.6.0.0' Message will be toggle for 5 sec.
Now unit will allow the user to configure different parameters with options as described below.
2) Press ‘SET’ Key to move on to next parameter.
3) Press ‘UP / DOWN’ Key to scroll between parameter options.
i
TIMER RANGE & RESOLUTION
:
Range : 99.99 Sec.
Resolution : 0.01 Sec.
Range : 999.9 Sec.
Resolution : 0.1 Sec.
Range : 9999 Sec.
Resolution : 1 Sec.
Range : 99 Min. 59 Sec.
Resolution : 1 Sec.
Range : 999.9 Min.
Resolution : 0.1 Min.
Range : 9999 Min
Resolution : 1 Min.
9999
Sec.
Range 2
Min
Min
Min
Min
Min
Hrs
Sec
Hrs
Sec
Min
Hrs
Sec
Hrs
Sec
Hrs
Sec
Hrs
Sec
TIMER RANGE & RESOLUTION
:
Range : 99.99 Sec.
Resolution : 0.01 Sec.
Range : 999.9 Sec.
Resolution : 0.1 Sec.
Range : 9999 Sec.
Resolution : 1 Sec.
Range : 99 Min. 59 Sec.
Resolution : 1 Sec.
Range : 999.9 Min.
Resolution : 0.1 Min.
Range : 9999 Min
Resolution : 1 Min.
Range : 99 Hrs. 59 Min.
Resolution : 1 Min.
Range : 999.9 Hrs.
Resolution : 0.1 Hrs.
Range : 9999 Hrs.
Resolution : 1 Hrs.
9999
Sec.
Range 1
Min
Hrs
Min
Sec
Hrs
Sec
Hrs
Min
Sec
Hrs
Min
Sec
Hrs
Min
Sec
Hrs
Sec
Min
Hrs
Min
Sec
Hrs
Min
Sec
Hrs
Min
Sec
On
Delay
Timer
Function
ON DELAY : Outputs are de-energized at power on. It remains De-energized after
start of timing cycle. After completions of timing cycle outputs are energized.
OFF DELAY
:
Outputs are energized at the start of timing cycle. After completions
of timing cycle outputs are de-energized.
CYCLIC WITH OFF TIME FIRST
:
St1 : Off-time
St2 : On-time
CYCLIC WITH ON TIME FIRST
:
St1 : On-time
St2 : Off-time
CYCLIC WITH HOLD TIME
:
StH : Hold Time
St1 : Forward-Time ; St2 : Reverse-Time
Lower
Display
Description
Default
Parameter
Upper
Display