Document Name : OIM V 1.0 Page 1 of 7

i

INSTALLATION GUIDELINES

1.  Prepare the cut-out with proper dimension as shown in figure.      
2.  Remove clamp from Controller.
3.  Push the Timer through panel cut-out and secure the 
Controller in its place by tightening the side clamp.

SPECIFICATIONS :

Display

           : Dual 4

Status Indication

: a

Relay status (OP1/OP2)

    

b] Auto Reset / EOC Time (RT)
c] Time Unit (Hrs. / Min. / Sec.)

Control Inputs

:  a] Count Input (For Counter)

b] Start Input (For Timer)
b] Reset Input 

Reset time

:  < 100 ms

Timing Accuracy

:  0.05%   Full Scale

Repeat Accuracy

 

:  0.01%

Outputs

 

:  5 Amp  @ 230VAC Relay (1C/O) x 2

Reset

 

:  a] Front switch (Programmable)

   

b] Remote Reset (via rear terminals)

   

C] At On power  (Programmable)

Supply

:  90 to 270 VAC

Mounting

 

:  Panel

Housing

 

:  ABS Plastic

o

Operating temp.

 

:  0 ~ 50  C

Humidity

 

:  95% Rh (Non Condensing).

 
Configurable Parameters:
Mode

: a] Counter

b] Timer

Counter Parameters :
Count Input

: AC / DC

Count Frequency 

: Various selectable frequencies

(For DC Input only)
Count direction      

:  Up / Down

Function 

: On Delay / Off Delay

Timer Parameters :
Count direction      

:  Up / Down

Timer Start

: Various selectable start mode

Timer Function

: a] ON / OFF delay b] Cyclic mode 

Output 2 Function 

: a] Auxiliary

b] End of Cycle (EOC)

c] Off

d] Invert

 Digit 7-segment LED, 

SAFETY INSTRUCTION
MECHANICAL

v

Ambient  temperature  and  relative  humidity  surrounding  the 
Controller must not exceed the maximum specified limits.

v

The Controller in its installed state must be protected against
excessive electrostatic or electromagnetic interferences. 

ELECTRICAL

v

The Controller must be wired as per wiring diagram & it must 
comply with local electrical regulation.

v

The Electrical noise generated by switching inductive loads 

might create momentary Fluctuation in display,  latch up, data 
loss or permanent damage to the instrument. To reduce this use 
snubber circuit across  the load.

B

D

A

G

F

PANEL

CUTOUT

E

C

OVER ALL DIMENSIONS & PANEL CUT OUT (IN MM)

+12V

PNP

NPN

GND

RST 

+12V

PNP

NPN

GND

RST 

Contact Switch

Proximity (NPN)

Proximity (PNP)

Wiring For Count Input & Remote Start

PNP

+12V

RST 

GND

NPN

1

2

RST 

+12 V

PNP

NPN

GND

HLD 

7

8

11

10

9

12

4

3

5

6

KTC-44

SUPPL

Y

L

N

NO 1

CM 1

+

-

NO 2

CM 2

+

-

TERMINAL CONNECTIONS :

OP

 1

OP

 2

5

4

3

RST 

+12 V

PNP

NPN

GND

HLD 

KTC - 77

1

2

8

7

6

SUPPL

Y

L

N

9

10

13

12

11

14

15

16

-

NO 2

CM 2

NC 2

+

-

NO 1

CM 1

NC 1

+

OP 1

OP 2

22

21

20

19

18

17

RST 

+12 V

PNP

NPN

GND

HLD 

KTC-99

SUPPL

Y

L

N

1

2

4

3

5

16

15

12

13

14

8

7

6

10

9

11

-

NO 1

CM 1

NC 1

+

-

NO 2

CM 2

NC 2

+

OP 2

OP 1

Model

Dim

96

72

48

96

72

48

14

14

14

80

80

86

92

68

44

92

68

44

KTC - 99

KTC - 77

KTC - 44

A

B

C

D

F

G

E

90

70

44

Display height (SV)

Display height (PV)

Model no.

0.36”

KTC-44

0.36”

KTC-77

0.39”

0.56”

KTC-99

0.80”

0.56”

White

Green

Display Colour

USER’S  OPERATING  MANUAL  FOR  DIGITAL  PRESET  TIMER  COUNTER

(Models: KTC - 44 / 77 / 99) 

KTC - 99

(96 X 96)

(72 X 72)

KTC - 77

KTC - 44

(48 X 48)

Содержание KTC-44

Страница 1: ...urrounding the Controller must not exceed the maximum specified limits v The Controller in its installed state must be protected against excessive electrostatic or electromagnetic interferences ELECTR...

Страница 2: ...ery Low If selected count input frequency is 3Hz Low If selected count input frequency is 30Hz Medium If selected count input frequency is 100Hz High If selected count input frequency is 1000Hz Very H...

Страница 3: ...d in Memory Counter will be Reset at next power On Enable If selected At the time of Power Failure Running Count value is Stored in Memory Enable Upper Display Parameter Description Default Lower Disp...

Страница 4: ...Min Resolution 1 Min 9999 Sec Range 2 Min Min Min Min Min Hrs Sec Hrs Sec Min Hrs Sec Hrs Sec Hrs Sec Hrs Sec TIMER RANGE RESOLUTION Range 99 99 Sec Resolution 0 01 Sec Range 999 9 Sec Resolution 0 1...

Страница 5: ...e at back terminal from external Input Remote Edge Negative Trigger Start If Selected Timer starts counting only when it detects low to high pulse at back terminal from external Input Remote Edge Trig...

Страница 6: ...put can be used as a Gate input i Disable Memory Backup Memory Backup This parameter allows the user to Enable or Disable memory backup function Enable Memory backup for run time value Disable No memo...

Страница 7: ...ec Hrs Min Sec Set Time Set EOC Time Running Time Set Time Number of cycles Total Time b For CY3 0 01 999 9 5 0 FORWARD TIME Prompted only if selected mode is CY3 Cyclic with Hold Sets the FORWARD tim...

Отзывы: