- 7 - 

 
Pressing the Control button while the blinking CAL is displayed will initiate a free air calibration on ALL connected 
wideband devices. 
 

5. Programming the XD-16 

 
You will need: 
 
1. XD-16 to Computer cable (male 2.5mm Stereo to DB-9) 
2. XD-16 Terminator plug (single male 2.5mm Stereo plug) 
3. A laptop computer 
4. When powered by the car, the ignition of the car must be on to power the XD-16. Alternatively you can power 
the XD-16 with a suitable power source between 8V and 25V. A normal 9V battery can be used to power the XD-
16. 
 

5.1. Installing the LM Programmer Software 

 
Put the included CD in your CD-drive on your computer and follow the instructions on screen.  The Software will 
be installed including pre-set directories for log-data and downloaded software.  The LM Installer also puts entries 
for the LM Software in the Start-Menu of your computer under the heading ‘Innovate!’. 
 
The following items will be installed on your hard-drive 
 

1.  LM Programmer Version 3.0 

This is used to program the XD-16 
 

2. LogWorks 

This is a comprehensive datalogging and analysis package to download and analyze engine data 
recorded with Innovate devices. It also allows real-time logging and display. 
LogWorks allows to program the relationship between sensor voltages recorded by the LM-1 or LMA-3 
and the indicated values. This relationship will be programmed into the XD-16 for the selected 
channel/input. 
 

3.  This manual (XD-16 Manual) 

 

4.  The LogWorks Manual 

Describes how to use LogWorks for datalogging and engine analysis. 

 

5.  The RPM converter (LMA-2) Manual 

Describes how to operate and use the LMA-2 RPM converter and how to connect different engine 
sensors. Used for LM-1 users. 

 

6.  The current firmware for the XD-16 

 

7.  An example datalog file 

 

5.2. Setting up the used inputs in LogWorks.  

 
Make sure the input channels to be used by the XD-16 are correctly programmed in LogWorks as they would 
show up on the LogWorks screen. Refer to the LogWorks manual for details. When programming the XD-16 the 
current real time settings of LogWorks are used to program the XD-16. 
 

 

Содержание XD-16

Страница 1: ...XD 16_Manual_1 3 doc XD 16 Digital Universal Dash Display User Manual ...

Страница 2: ...g the LM Programmer Software 7 5 2 Setting up the used inputs in LogWorks 7 5 3 Connecting the XD 16 device to the computer 7 5 4 Updating the Firmware 8 5 5 Selecting the display channel 9 5 6 Programming the Min Max hold functions 10 5 7 Programming the Warning Alarm function 11 5 8 Programming the Analog needle colors 12 6 Changing the gauge face of the XD 16 13 6 1 Installing the new gauge fac...

Страница 3: ... user customized The XD 16 can also be used to initiate and control recording on the LM 1 or other Innovate Recording devices can initiate free air calibration for Innovate Motorsports wideband controllers and indicate wideband controller status In addition the XD 16 can be programmed to hold minimum maximum values of the displayed channel and provide warnings alerts depending on programmable warn...

Страница 4: ... or recording device like the LM 1 The record indicator will blink when a LM 1 or other Innovate Motorsports recording product is attached and actively recording 2 2 Included cables and devices 1 XD 16 to LM 1 cable Mini DIN 8 to female 2 5mm Stereo Use with patch cable 3 below 2 XD 16 to Computer cable male 2 5mm Stereo to DB 9 3 Male 2 5mm Stereo to male 2 5mm Stereo cable 4 XD 16 Terminator plu...

Страница 5: ...o light up all LEDs until the button is released 4 1 Displayed functions when using XD 16 as AFR Lambda display 1 Sensor Warm up For example this would indicate that he heater is warmed up to 56 The Function Indicator 2 is lit 2 Heater Calibration The last digit is the count down of the heater calibration 3 Free air calibration in process When shown steady free air calibration is in progress If bl...

Страница 6: ...icated Note that the XD 16 will remember the minimum value even if power is switched off Minimum value is indicated by alternating between and the minimum value stored Holding the Control button down for a few seconds while this is displayed will reset the minimum value Press the Control button instead only briefly will show the maximum value indicated It is indicated by alternating between and th...

Страница 7: ...ur hard drive 1 LM Programmer Version 3 0 This is used to program the XD 16 2 LogWorks This is a comprehensive datalogging and analysis package to download and analyze engine data recorded with Innovate devices It also allows real time logging and display LogWorks allows to program the relationship between sensor voltages recorded by the LM 1 or LMA 3 and the indicated values This relationship wil...

Страница 8: ...ion dld You can also download the latest firmware and software LM Programmer and Demo from the Innovate Motorsports web site at http www tuneyourengine com If your computer crashes during a firmware upgrade the XD 16 has a recovery mechanism where it will be able to retry the download again and not be disabled by half loaded firmware Switch the XD 16 off and on again and then try to restart the LM...

Страница 9: ... needle LEDs Press the program button when you are finished If you select something other than a Lambda AFR channel you will first need to connect all your MTS devices or LM 1 to LogWorks and complete a real time log LogWorks compiles channel information through this process Exit LogWorks and reconnect to LM Programmer The list of available devices channels will be now be selectable from the Input...

Страница 10: ... the XD 16 can display the RPM in multiples of 10 RPM If a channel is selected that has both positive and negative values a different screen will show This allows you to use the Indicator 1 and 2 LEDs as negative value indicators to preserve the 3 digit resolution of the XD 16 5 6 Programming the Min Max hold functions Click on the Min Hold or Max Hold Tab on the top of the window The following sc...

Страница 11: ...leanest AFR is only stored during WOT operation and only if the condition persists for more than 0 2 seconds In this case AFR was used as input and you don t want to store the leanest AFR during closed throttle where the injectors cut off Any channel can be programmed as dependency You can program any minimum persist time between 0 and 10 seconds 5 7 Programming the Warning Alarm function Click on...

Страница 12: ...gramming as described in 4 6 Except here the Alarm condition can be programmed to be dependent on two other channels and time During an Alarm the XD 16 will flash the indicated value and the analog needle LEDs at maximum brightness until the Alarm condition goes away ...

Страница 13: ...tios The XD 16 can be programmed for 32 different values for each red green and blue And 32x32x32 is 32768 But black all off is hardly used While moving the sliders the simulated LED on the screen changes color and also the appropriate LED on the XD 16 at the same time Because computer screens use a different technology to create colors than the XD 16 the actual colors on the XD 16 can be differen...

Страница 14: ... Carefully lift out the back plate with the electronics package from the bezel 3 Laying the electronics package on its back first place the gauge face followed the glass and bezel Be sure to remove protective film from the gauge face This can be done easily with a piece of scotch tape Make sure every piece is positioned correctly on the button shaft 4 Carefully flip the complete assembly and line ...

Страница 15: ...er printer different foils will be needed 1 ExactoTM knife or razor blade or scissors 2 Piece of plywood or sturdy cardboard as cutting background Do not use the kitchen table 3 A 1 8 hole punch Leather equipment stores or horse tack stores carry those 4 A small Phillips screw driver 5 Blank white XD 16 face included 6 3 Assembly sequence of the XD 16 with foil face Appendix A Specifications Suppl...

Страница 16: ... 16 Revision History 1 0 2 5 05 Initial release 1 1 3 16 05 Corrected misc errata 1 2 4 11 05 Corrected section 2 2 1 3 2 06 06 Added XD 16 information ...

Отзывы: