background image

To prevent personal injury, or property or unit damage, adhere to all 
precautionary measures and instructions outlined in this manual. 
Before servicing a unit, refer to this service manual and its relevant 
sections.

Failure to adhere to all precautionary measures listed in this section
may result in personal injury, damage to the unit or 

WARNING

 indicates a potentially hazardous situation which 

if not avoided could result in serious personal injury, or death.

CAUTION

 indicates a potentially hazardous situation which if 

not avoided could result in minor or moderate personal injury, 
or unit damage.

1. In case of Accidents or Emergency

 

WARNING

If the unit comes into contact with liquid, contact an

If liquid from the batteries makes contact with skin or

Do not insert hands or other objects into the air inlet

Do not operate the unit with wet hands.
Do not use a remote controller that has previously

 

CAUTION

Clean and ventilate the unit at regular intervals whenoperating 

it near a stove or near similar devices.
Do not use the unit during severe weather conditions.

2. Pre-Installation and Installation

 

WARNING

Use this unit only on a dedicated circuit.
Damage to the installation area could cause the unit

emove, or 

repair the unit.

work. For 

more information, contact your dealer,seller, or an authorized 

Innovair service center.

 

CAUTION

While unpacking be careful of sharp edges around

denser and evaporator.

3. Operation and Maintenance

 

WARNING

Do not use defective or under-rated circuit breakers.
Ensure the unit is properly grounded and that a
dedicated circuit and breaker are installed.
Do not modify or extend the power cable. Ensure
the power cable is secure and not damaged during

operation.
Do not unplug the power supply plug during
operation.

unit.

Do not open the inlet grill of the unit during

Do not use harsh detergents, solvents, or similar itemsto clean 

the unit. Use a soft cloth for cleaning.
Do not touch the metal parts of the unit when

Do not step on or place anything on the unit oroutdoor 

units.
Do not drink water drained from the unit
Avoid direct skin contact with water drained from the

manufacturer 

procedures when cleaning ormaintaining the unit.

 

CAUTION

Do not install or operate the unit for an extendedperiod of 
time in areas of high humidity or in anenvironment directly 
exposing it to sea wind or saltspray.

Do not install the unit on a defective or damaged
installation stand, or in an unsecure location.
Ensure the unit is installed at a level position
Do not install the unit where noise or air discharge

Do not expose skin directly to the air discharged by
the unit for prolonged periods of time.
Ensure the unit operates in areas water or other

Ensure the drain hose is installed correctly to ensure
proper water drainage.

When lifting or transporting the unit, it is

When the unit is not to be used for an extended time,

Do not 

 

Service

 Manual

w w w . i n n o v a i r . c o m

Содержание PIN09H1V51

Страница 1: ...with safety procedures and equipped with the proper tools and test instruments Installation or repairs made by unqualified persons can resu t in hazards to you and others Failure to carefully read and follow all instructions in thi manual can result in equipment malfunction property damage personal injury and or death This service is only for service engineer to use Service Technical Manual ...

Страница 2: ...Contents Service Manual ...

Страница 3: ...be careful of sharp edges around denser and evaporator 3 Operation and Maintenance WARNING Do not use defective or under rated circuit breakers Ensure the unit is properly grounded and that a dedicated circuit and breaker are installed Do not modify or extend the power cable Ensure the power cable is secure and not damaged during operation Do not unplug the power supply plug during operation unit ...

Страница 4: ...ttention to such a situation Be sure not to do Grounding is essential Warning Incorrect handling could cause a serious hazard Symbols in this Use and Care Manual are interpreted as shown below Service Manual ...

Страница 5: ...Service Manual w w w i n n o v a i r c o m 3 ...

Страница 6: ... service agent or similarly qualified persons in order to avoid a hazard interconnection Before using the air conditioner be sure to check and preset the following Each tim e after the remote control is replaced with new batteries or is energized re mote control auto presetting heat pump If the air conditioner you purchased is a Cooling Only one heat pump remote controller can also be used Hold do...

Страница 7: ...Service Manual w w w i n n o v a i r c o m 5 ...

Страница 8: ...6 Service Manual ...

Страница 9: ...92x240 715x492x240 780 605 290 845 699 380 Outdoor inch 28 66x21 65x11 22 28 66x21 65x11 22 28 14x19 37x9 44 28 14x19 37x9 44 30 70x23 81x11 41 33 26x27 51x14 96 Indoor kg Ibs 8 17 6 8 17 6 8 17 6 8 17 6 13 28 7 17 37 5 Net weight Outdoor kg Ibs 29 63 9 29 63 9 27 59 5 27 59 5 33 5 73 8 45 99 2 mm 885x366x278 885x366x278 885x366x278 885x366x278 1094 386 300 1265 415 338 Indoor Packing dimensions W...

Страница 10: ...8 Service Manual ...

Страница 11: ...Service Manual w w w i n n o v a i r c o m 9 ...

Страница 12: ...10 Service Manual ...

Страница 13: ...Service Manual w w w i n n o v a i r c o m 11 ...

Страница 14: ...12 Service Manual ...

Страница 15: ...Service Manual w w w i n n o v a i r c o m 13 ...

Страница 16: ...14 Service Manual ...

Страница 17: ...Service Manual w w w i n n o v a i r c o m 15 ...

Страница 18: ...16 Service Manual ...

Страница 19: ...Service Manual w w w i n n o v a i r c o m 17 ...

Страница 20: ...18 Service Manual ...

Страница 21: ...Service Manual w w w i n n o v a i r c o m 19 ...

Страница 22: ...20 Service Manual ...

Страница 23: ...Service Manual w w w i n n o v a i r c o m 21 ...

Страница 24: ...22 Service Manual ...

Страница 25: ...Service Manual w w w i n n o v a i r c o m 23 ...

Страница 26: ...24 Service Manual ...

Страница 27: ... disrchare pipe sensor connection terminal is loose or not plugged in E0 Indoor Outdoor Communication Issue E5 Indoor Outdoor Communication Issue EA Possible refrigerant leakage or outdoor control board damaged E9 Outdoor control board drive circuit damaged P0 Outdoor control board drive circuit damaged P9 Outdoor control board drive circuit damaged EU Voltage sensor damaged EE EEPROM Fault CL Cle...

Страница 28: ...26 Service Manual ...

Страница 29: ...Service Manual w w w i n n o v a i r c o m 27 ...

Страница 30: ...28 Service Manual ...

Страница 31: ...Service Manual w w w i n n o v a i r c o m 29 ...

Страница 32: ...30 Service Manual ...

Страница 33: ...Service Manual w w w i n n o v a i r c o m 31 ...

Страница 34: ...32 Service Manual ...

Страница 35: ...Service Manual w w w i n n o v a i r c o m 33 ...

Страница 36: ...34 Service Manual ...

Страница 37: ...Service Manual w w w i n n o v a i r c o m 35 ...

Страница 38: ...36 Service Manual ...

Страница 39: ...Pipe Fixer 1 13 42003 000051 Indoor Motor Cover 1 14 41105 000134 Electrical Box 1 15 31101 000265 Main PCB 1 16 NO Transformer 1 17 42001 000103 Cable Clamp 1 18 22001 000313 Vane Motor 1 1 19 41102 000091 Base 1 20 41101 000082 Vertical Vane Assembly 2 21 41103 000102 Vane 1 22 41109 000041 Installation Plate 1 23 10104 100014 Indoor Sensor Assembly 1 24 22013 001263 Remote Controller 1 25 42009...

Страница 40: ...Right Plate 1 15 92007 001050 Two way Valve 1 16 41204 000018 Valve Supporter 1 17 92007 001041 Three way Valve 1 18 41201 000044 Electrical Box Cover 1 19 11304 100046 Terminal 1 20 42001 000036 Cable clamp1 1 21 31201 000973 Outdoor PCB Assembly 1 22 22011 000011 Inductor 1 23 92007 002097 Capillary assembly 1 24 41208 000147 Partition plate 1 25 10104 100036 Pipe Temp sensor and outdoor Temp se...

Страница 41: ...Pipe Fixer 1 13 42003 000051 Indoor Motor Cover 1 14 41105 000134 Electrical Box 1 15 31101 000226 Main PCB 1 16 NO Transformer 1 17 42001 000103 Cable Clamp 1 18 22001 000313 Vane Motor 1 1 19 41102 000091 Base 1 20 41101 000082 Vertical Vane Assembly 2 21 41103 000102 Vane 1 22 41109 000041 Installation Plate 1 23 10104 100014 Indoor Sensor Assembly 1 24 22013 001263 Remote Controller 1 25 42009...

Страница 42: ...02 000216 Base 1 14 41205 000085 Right plate 1 15 92007 001050 Two way valve 1 16 41204 000018 Valve supporter 1 17 92007 001041 Three way valve 1 18 41201 000044 Eelectronic Box Cover 1 19 42001 000036 Cable clamp 1 20 11304 100045 Terminal 1 21 31201 000976 Outdoor PCB Assembly 1 22 22011 000002 Inductor 1 23 92007 002063 Capillary assembly 1 24 41208 000141 Partition plate 1 25 10104 100047 Pip...

Страница 43: ...door Motor Cover 1 14 41105 000134 Electrical Box 1 15 31101 000238 Main PCB 1 16 NO Transformer 1 17 42001 000103 Cable Clamp 1 22001 000321 Vane Motor 1 1 22001 000318 Vane Motor 1 1 19 41102 000069 Base 1 20 41101 000042 Vertical Vane Assembly 3 21 41103 000142 Vane 1 22 41109 000019 Installation Plate 1 23 10104 100014 Indoor Sensor Assembly 1 24 22013 001263 Remote Controller 1 25 42009 00001...

Страница 44: ...205 000087 Right Plate 1 15 92007 001052 Two way Valve 1 16 41204 000018 Valve Supporter 1 17 92007 001041 Three way Valve 1 18 41201 000044 Electrical Box Cover 1 19 11304 100045 Terminal 1 42001 000038 Cable clamp1 1 42001 000036 Cable clamp2 1 21 31201 000967 Outdoor PCB Assembly 1 22 22011 000014 Inductor 1 23 92007 002112 Capillary Assembly 1 24 41208 000154 Partition plate 1 25 10104 100038 ...

Страница 45: ...09 Display PCB 1 10 42003 000001 Display PCB Box 1 11 42008 000041 Air Filter 2 12 41106 002086 Front Panel 1 13 41103 000317 Up Vane 1 14 41103 000312 Down Vane 1 15 42009 000004 Drainage Hose 1 16 42001 000103 Cable Clamp 1 41103 000050 Vane Motor 2 22001 000357 Vane Motor 2 18 31101 000280 Main PCB 1 19 41108 000006 Indoor Motor Cover 1 20 22001 000240 Indoor Motor 1 21 41105 000139 Electrical ...

Страница 46: ...237 Base 1 14 41205 000088 Right Plate 1 15 92007 001057 Two way Valve 1 16 41204 000018 Valve Supporter 1 17 92007 001054 Three way Valve 1 18 41201 000044 Electrical Box Cover 1 19 11304 100045 Terminal 1 42001 000038 Cable clamp1 1 42001 000036 Cable clamp2 1 21 31201 000978 Outdoor PCB Assembly 1 22 22011 000004 Inductor 1 23 92007 002125 Capillary Assembly 1 24 41208 000155 Partition plate 1 ...

Страница 47: ...Service Manual w w w i n n o v a i r c o m 45 ...

Страница 48: ...46 Service Manual ...

Страница 49: ...Service Manual w w w i n n o v a i r c o m 47 ...

Отзывы: