9. Electronic Function
9.1 Abbreviation
T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
T5: Compressor discharge temperature
9.2 Display function
9.2.1 Icon explanation on indoor display board.
Defrost
Indicator
This indicator illuminates when the
air conditioner starts defrosting
automatically or when the warm air
control feature is activated in
heating mode(only for heat pump)
Run
indicator
Flash at 0.5Hz when the unit is
standby. Illuminate when the unit is
turned on.
Timer
indicator
This indicator illuminates when
TIMER is set ON/OFF.
Temperature indicator
Displays the temperature settings
when the air conditioner is
operational. Displays the malfunction
code.