Cleaning the Grille, Case and Remote Controller

A cloth dampened with cold water may be used

on the indoor unit if it is very dirty. Then wipe it
with a dry cloth.
Do not use a chemically treated cloth or duster to
clean the unit.
Do not use benzine, thinner, polishing powder, or
similar solvents for cleaning. These may cause

the plastic surface to crack or deform.
Never use water hotter than 40 C/104 F to clean
the front panel, it could cause deformation of
discoloration.

CAUTIONS

CARE AND MAINTENANCE

Care and Maintenance

Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.

NOTE: Power supply must be disconnectd before
cleaning the indoor unit.

Filter Handle

A clogged air filter reduces the cooling efficiency of
this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it

stops with a clicking sound.For 24K Btu model,
please use suspension bars to prop up the panel.

2. Take hold of the handle of the air filter and lift it

up slightly to take it out from the filter holder,
then pull it downwards.

3. Remove the AIR FILTER from the indoor unit.

Clean the AIR FILTER once two weeks.
Clean the AIR FILTER with a vacuum cleaner
or water, then dry it up in cool place.

Cleaning the air filter

OPERATING INSTRUCTIONS

How the air conditioner works

1 hour

1 hour

Set
Temperature

Set
Temperature

Cooling

Heating

SLEEP operation

1 hour 1 hour

SLEEP operation

7 hours timer off

7 hours timer off

AUTO operation

SLEEP operation

DRYING operation

Optimal operation

When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on set
temperature and the room temperature.
The air conditioner will control room temperature
automatically to the temperature point you set.
If you feel uncomfortable in the AUTO mode, you can set
your desired temperature.

When you push SLEEP button on remote controller
during cooling, heating(cooling & heating models only),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease (heating)

per hour for the first 2 hours, then hold

steadily for the next 5 hours, after that it will switch off.
This mode saves you energy and brings you comfort
at night.

To achieve optimal performance, please note the
following:
Adjust the air flow direction correctly so that it is not
forwards people.
Adjust the temperature to achieve the highest comfort
level. Do not adjust the unit to excessive temperature
levels.
Close doors and windows on COOL or HEAT modes,
or performance may be reduced.
Use TIMER ON button on the remote controller to
select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the
efficiency of the air conditioner may be reduced and
the air conditioner may stop running.
Clean the air filter periodically, otherwise cooling or
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed
position.

The fan speed will be automatically controlled under
dry operation.
During the dry operation, if the room temperature is
lower than 10 C(50 F), the compressor stops operation
and restarts until the room temperature is above
12 C(54 F).

O

O

O

O

NOTE: Power supply must be disconnectd before
cleaning the indoor unit.

Содержание 2nd Generation

Страница 1: ...ventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service The design and specifications are subject to change without prior notice for product improvement Consult with the sale...

Страница 2: ... read the following information SOCIABLE REMARK SAFETY PRECAUTIONS OPERATING INSTRUCTIONS CARE AND MAINTENANCE OPERATION TIPS TROUBLESHOOTING TIPS Sociable remark 2 Warning 3 Caution 4 Parts names 5 Special functions 6 Operating temperature 7 Manual operation 7 Airflow direction control 8 How the air conditioner works 9 Care and maintenance 10 Operation tips 12 Troubleshooting tips 14 Contact the ...

Страница 3: ...bles such as gasoline benzene thinner etc Do not disassemble or modify unit WARNING Use the correctly rated breaker or fuse There is risk of fire or electric shock SAFETY PRECAUTIONS CAUTION When the air filter is to be removed do not touch the metal parts of the unit It may cause an injury Do not clean unit when power is on as it may cause fire electric shock or injury Operation with windows open...

Страница 4: ...outlet 5 6 7 Display panel Horizontal air flow grille Vertical air flow louver inside Indoor unit 4 3 5 2 6 1 9 10 8 7 Model Name And Dimensions MODEL WIDTH mm HEIGHT mm DEPTH mm 9000 Btu 12000 Btu 18000 Btu 255 255 275 180 188 198 680 770 905 24000 Btu 1030 315 220 Louver Angle Memory Function optional Within the scope of safety angle it will memorize the open angle of horizontal louver If it exc...

Страница 5: ...INSTRUCTIONS Manual operation NOTE This manual does not include Remote Controller Operations see the Remote Controller Instruction packed with the unit for details Operating temperature Suspension bars AUTO COOL 1 2 Manual control button fl Mode Temperature Room temperature Outdoor temperature 1 Optimum performance will be achieved within these operating temperatures If air conditioner is used out...

Страница 6: ...you set the air conditioner in AUTO mode it will automatically select cooling heating cooling heating models only or fan only operation depending on set temperature and the room temperature The air conditioner will control room temperature automatically to the temperature point you set If you feel uncomfortable in the AUTO mode you can set your desired temperature When you push SLEEP button on rem...

Страница 7: ...ar smell comes out from the indoor unit 6 When indoor temperature reaches the temperature setting on air conditioner the compressor will stop automatically and the air conditioner turns to FAN only mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling and heating models only to the set point 7 The air conditioner turns to FAN only mod...

Страница 8: ...t and releases it via the indoor unit during heating operation When the outdoor temperature falls heat drawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating dev...

Отзывы: