PROBLEMS AND SOLUTIONS
In the event of a malfunction, refer to the following table. If, after performing the suggested checks, the problem is not
solved, call the Customer Support Call Center at for assistance.
PROBLEM
POSSIBLE CAUSES
SOLUTION(S)
THE HPAC 2.0
DOESN’T TURN ON
No power
Check that there is power to the grounded three-prong
electrical power outlet that is powering the HPAC 2.0
by plugging in a lamp to the same outlet. Repair the
grounded three-prong electrical power outlet or use a
different one.
The fuse is blown/circuit
breaker is tripped
You may notice a few minutes’ delay in starting if
you try to restart the HPAC 2.0 too soon after turning
it off, or if you adjust the thermostat right after the
compressor has shut off. This is due to a built-in restart
protector for the compressor that causes a three-minute
delay.
The HPAC 2.0 is unplugged
During the defrost cycle, both the indoor and outdoor
fans stop and the compressor will operate in the
cooling mode to remove frost from the outdoor coil.
After defrosting, the HPAC 2.0 will restart in electric heat
to quickly warm the room to the desired comfort level.
The HPAC 2.0 is waiting for
the compressor overload
protector to reset
To protect the compressor and prevent short cycling,
the HPAC 2.0 is designed to run for a minimum of three
minutes after the compressor starts at any thermostat
setting.
The current interrupter
device is tripped
Press the RESET button located on the power supply
cord plug or the box near the power plug.
If the RESET button will not stay engaged, discontinue
use of the HPAC 2.0 and contact a qualified service
technician.