19P03-DOC01E REV-3
58
12. Use a 9/16” combination wrench to hold the bolt (F) and use a 1/2” combination
wrench to remove the nut (D). Then remove the bolt (F) from the turn buckle.
13. Remove the socket head shoulder bolt (A) with a 1/4” Allen Socket and a 3/8”
drive ratchet.
14. Slowly remove the load cell with the bed caster support until the load cell
connectors are available and then unplug it. The defective load cell cable should
be now free to remove from the bed frame.
15.
Reverse the above steps to install the new load cell cable.
16. Verify that the new load cell is working properly before putting the bed back in
service.
Notice:
Be careful to put the plastic bushing in the right way.
Went installing the load cell to the base frame, be careful to not squeeze
the new cable between the load cell and the base frame.
Put the bed caster back on the ground by removing the axle stands before
completely tightening the socket head shoulder bolt (A).