CAUTION!
Changes or modifications not expressly approved by INNOTEK
CORPORATION could void the user’s authority to operate the equipment
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause. The LED will flash rapidly.
WARNING!
If the unit alarms and you are not testing the unit it is warning you of a
potentially dangerous situation that requires your immediate attention.
NEVER ignore any alarm. Ignoring the alarm may result in injury or death.
Never remove the batteries from a battery operated Smoke Alarm to stop an
unwanted alarm (caused by cooking smoke, etc.). Removing batteries
disables the alarm so it cannot sense smoke, and removes your protection.
Instead open a window or fan the smoke away from the unit. The alarm will
reset automatically.
If the unit alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’t stop to get dressed or
collect anything.
Feel doors with the back of your hand before opening them. If a door is cool,
open it slowly. Don’t open a hot door. Keep doors and windows closed,
unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp). Take short,
shallow breaths.
Meet at your planned meeting place outside your home, and do a head count
to make sure everybody got out safely.
Call the Fire Department as soon as possible from outside. Give your
address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
WARNING!
Alarms have various limitations. See “Limitations of Smoke Alarms” for details.
IF YOU SUSPECT A PROBLEM
Smoke Alarms may not operate properly because of dead, missing or weak
batteries, a build-up of dirt dust or grease on the Smoke Alarm cover or
installation in an improper location. Clean the Smoke Alarm as described in
“Regular Maintenance,” and install a fresh battery then test the Smoke Alarm
again. If it fails to test properly when you use the test button, or if the problem
persists, replace the Smoke Alarm immediately.
If you hear one “beep” about once a minute, replace (9volt) battery.
If you hear two “beeps” about once a minute, replace (AA) batteries.
If you experience frequent non-emergency alarms (like those caused by
cooking smoke), try relocating the Smoke Alarm.
If the alarm sounds when no smoke is visible, try cleaning or relocating the
Smoke Alarm. The cover may be dirty
If the alarm does not sound during testing, try installing a new battery, and
make sure it is snapped in securely.
Do not try fixing the Alarm yourself- this will void your warranty!
If the Smoke Alarm is still not operating properly and it is still under warranty
please see “How to Obtain Warranty Service” in the Limited Warranty.
FCC NOTICE
: This device complies with Part 15 of the FCC Rules. Operation
Is subject to the following two conditions; (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
PROTEKWIRELESS
™
INNOTEK CORPORATION
11616 E. Montgomery Suite #4
Spokane Valley, WA 99206
SPECIAL COMPLIANCE CONSIDERATIONS
WARNING!
This Smoke Alarm alone is not suitable substitute for complete fire detection
systems in places housing many people – like apartment buildings,
condominiums, hotels, motels, dormitories, hospitals, tong-term health care
facilities, nursing homes, day care facilities, or group homes of any kind – even
if they were once single-family homes. It is not s suitable substitute for complete
fire detection systems in warehouses, industrial facilities, commercial buildings,
and special-purpose non-residential buildings which require special fire
detection and alarm systems. Depending on thy building codes in your area, this
Smoke Alarm may be used to provide additional protection in these facilities.
In new construction, most building codes require the use of AC or AC/DC
powered Smoke Alarms only In existing construction, AC, AC/DC, or
DC
powered Smoke Alarms can be used as specified by local building codes. Refer
to NFPA 101 (Life Safety Code) or NFPA 72 (National Fire Alarm Code), local
building codes, or consult your Fire Department for detailed fire protection
requirements in buildings not defined as households.
For your information, the National Fire Protection Association’s Standard 72,
reads as follows:
²2-2.1.1.1 Smoke detectors shall be installed outside of each separate sleeping
area in the immediate vicinity of the bedrooms and on each additional story of the
family living unit including basements and excluding crawl spaces and unfinished
attics. In new construction, a smoke detector shall be installed in each sleeping
room. ²
²A-2.5.2.1 Smoke Detection - Are More Smoke Detectors Desirable? The
required number of smoke detectors might not provide reliable early warning
protection for those areas separated by a door from the areas protected by the
required smoke detectors. For this reason, it is recommended that the
householder consider the use of additional smoke detectors for those areas for
increased protection. The additional areas include the basement, bedrooms,
dining room, furnace room, utility room, and hallways not protected by the
required smoke detectors. The installation of smoke detectors in kitchens, attics
(finished or unfinished), or garages is not normally recommended, as these
locations occasionally experience conditions that can result in improper
operation.²
LIMITED WARRANTY
INNOTEK CORPORATION the maker of (PROTEKWIRELESS
™
) brand
products warrants that for a period of ten years from the date of manufacture,
this product will be free from defects in material and workmanship. INNOTEK, at
its option, will repair or replace this product or any component of the product
found to be defective during the warranty period Replacement will be made with
a new or remanufactured product or component if the product is no longer
available, replacement may be made with a similar product of equal or greater
value. This is your exclusive warranty.
This warranty is valid for the original homeowner from the date of manufacture
and is not transferable. Proof of purchase is required to obtain warranty
performance. INNOTEK dealers, service centers, or wholesale stores selling
INNOTEK products do not have the right to altar, modify or any way change the
terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from
any of the following: negligent use or misuse of the product, use on improper
voltage or current use contrary to the operating instructions, disassembly repair
or alteration by anyone other than INNOTEK CORPORATION or an authorized
service center Further, the warranty does not cover Acts of God, such as fire,
flood, hurricanes and tornadoes or any batteries that are included with this unit
INNOTEK CORPORATION shall not be liable for any incidental or
consequential damages caused by the breach of any express or implied
warranty except to the extent prohibited by applicable law any implied warranty
of merchantability or fitness for a particular purpose is limited in duration to the
duration of the above warranty. Some states, provinces or jurisdictions do not
allow the exclusion or limitation of incidental or consequential damages or
limitations on how long an implied warranty lasts, so the above limitations or
exclusion may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights that vary from state to state or province to
province.
How to Obtain Warranty Service
Service:
If service is required, return the product to your contractor. In order to
obtain warranty service, contact the Customer service department at
1-877-476-8133, 9:00 AM - 5:00 PM Pacific Standard Time, Monday through
Friday. To assist us in serving you, please have the model number and date of
install available when calling.