background image

Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor

Page 23

©  Mass Electronics Pty Ltd  2011

Edition 6.0 dated 04/01/2017

Cannot Launch FusionLIVE

• 

When first launching FusionLIVE from the IG04 BACnet Gateway's embedded web server, you 

may encounter a window that asks you to install the Java Runtime Environment (JRE). Ensure to 

follow the prompts to download the JRE from the internet. If you do not have available internet 

access, you will not be able to continue until you have downloaded and installed the JRE onto the 

computer. The latest version of JRE can be downloaded from 

http://java.com/en/

.

• 

If you have received an error message indicating the following, please try restarting FusionLIVE. If 

that fails to resolve the issue, you may need to restart Internet Explorer. These error messages can 

appear occasionally on some computers:

• 

Cannot launch

• 

Cannot find file

• 

Missing *.jnlp file

• 

Check that the JRE proxy settings are correct for the building network, and are switched on. Whilst 

these should be activated and inherited from Internet Explorer at launch of the JRE, in some 

instances this field can be blank. Enter the JRE proxy settings exactly as entered into Internet 

Explorer proxy settings.

Unstable Connection With Embedded Web Server or FusionLIVE

• 

If you are having stability issues with the embedded web server or FusionLIVE, ensure that you 

have no more than 5 concurrent computer connections to either of these services.  

• 

Performance and stability may be affected by network connection speed. When multiple 

computers are connected to the IG04 BACnet Gateway, the slowest connection speed can have an 

impact on all other connections. Try disconnecting slower connections to see if this helps.

Содержание Vaisala WMT

Страница 1: ...IG04 BACnet Gateway Vaisala WXT WMT INSTALLATION INSTRUCTIONS ...

Страница 2: ... the accuracy and clarity of this document Mass Electronics Pty Ltd assumes no liability resulting from any omissions in this document or from misuse of the information obtained herein The information in this document has been carefully checked and is believed to be entirely reliable with all of the necessary information included Mass Electronics Pty Ltd reserves the right to make changes to any p...

Страница 3: ...ng 8 Wiring Using The Screw Terminal Connector With Split Cabling For Heating 9 Vaisala Device Screw Terminal Pin Outs 10 Accessing Embedded Web Server and FusionLIVE 11 Home Page of Embedded Web Server 12 Animated Graphics on the Home Page 13 Configuring Vaisala Device with FusionLIVE 15 Configuring IG04 BACnet Gateway with FusionLIVE 16 System Tab 16 BACnet Tab 17 Clock Tab 18 Configuring Sunris...

Страница 4: ...oth the Vaisala device and optional heating accessory Ensure to use high capacity cable suitable for carrying such a current load over the distance required Refer to the following wiring guides for the most suitable option for your installation Supported Vaisala Device Models The IG04 BACnet Gateway communicates directly with the Vaisala device using a dedicated RS 485 channel The IG04 BACnet Gate...

Страница 5: ...nnotech IG04 BACnet Gateway BLK Wire Vin RED Wire Vin 24V 0V If a surge protector is not installed connect the cables directly RS485 S RS485 RS485 Shield RS485 Line Termination Jumper BLU Wire RX GRY Wire RX 1 2 3 4 5 6 7 8 YEL Vh PNK Vh RED Wire Vin BRN Wire Vin 1 RED Wire Vh BLK Wire Vh 24V to 32V DC 200mA 2 800mA 3 Note Colour coded as per Vaisala documentation GRY Wire RX BLU Wire RX WSP150 Su...

Страница 6: ...LU Wire RX GRY Wire RX Only used when heating is required 1 2 3 4 5 6 7 8 YEL Vh PNK Vh RED Wire Vin BRN Wire Vin 1 Note Colour coded as per Vaisala documentation GRY Wire RX BLU Wire RX IG04 Default Settings IP Address 192 168 2 100 Static S M 255 255 255 0 Innotech Port 20000 BACnet IP BACnet Port 47808 BACnet Instance 1509 Baud Rate 19200 Fault Timeout 30 Sec HTTP Port 80 16mm Copper Cable SER ...

Страница 7: ...GND Brown 2 Vin operating supply voltage Vaisala Device 8 Pin M12 Connector Pin Outs Please take extreme care to ensure when installing and wiring that the wire colours and terminals correctly match as illustrated in Figure 1 or Figure 2 and described below in Table 1 Refer to the appropriate Vaisala technical documentation for more details at www vaisala com Exact minimum cable specifications for...

Страница 8: ...he WSP150 Surge Protector in accordance with appropriate Vaisala technical documentation 2 When heating is NOT used 3 Higher heating currents cause voltage drop Select cable with sufficient cross section for longer runs Wiring Using The Screw Terminal Connector With Independent Cabling For Heating The wiring example provided below at Figure 3 is recommended for most installations providing a separ...

Страница 9: ... technical documentation 2 When heating is NOT used 3 When heating IS used If heating is required and supplied via the same supply wires ensure a substantial cable with cross section 1mm2 is used to avoid excessive voltage drops Excessive voltage drops may cause comms problems Wiring Using The Screw Terminal Connector With Split Cabling For Heating The wiring example provided below at Figure 4 is ...

Страница 10: ... HTG Vh heating supply voltage 19 VIN Vin operating GND 20 VIN Vin operating supply voltage Vaisala Device Screw Terminal Pin Outs Please take extreme care to ensure when installing and wiring that the wire colours and terminals correctly match as illustrated in Figure 1 or Figure 2 and described below in Table 2 Refer to the appropriate Vaisala technical documentation for more details at www vais...

Страница 11: ...e IP address and subnet mask of your computer you can access the web server using Microsoft Internet Explorer Web Browser Version 8 or greater Follow the instructions below to connect to the IG04 BACnet Gateway and access the embedded web server Launch Internet Explorer and enter the default IP address of the IG04 BACnet Gateway in the address bar and press Enter as illustrated in Figure 5 below F...

Страница 12: ...tween the IG04 BACnet Gateway and Vaisala device has been properly configured The embedded web server s home page for the Vaisala WXT Weather Transmitter is illustrated in Figure 7 below while the home page for the Vaisala WMT Ultrasonic Wind Sensor can be seen at Figure 8 From the embedded web server s home page you can click on the button to launch the FusionLIVE Java application to modify the V...

Страница 13: ...ons when connected to a Vaisala Weather Transmitter The range of graphics and their meanings are illustrated in below in Figure 9 Day Night Fine Day Night Fresh Breeze Day Night Strong Winds Day Night Showers Day Night Hail Day Night Drizzle Day Night Rain Figure 9 Animated graphics for home page The home page can automatically cycle through day night display mode when the Sunrise Sunset feature h...

Страница 14: ...n the button to modify or configure the Vaisala device settings Click on the button to modify or configure the IG04 BACnet Gateway settings 2 Transmitter Data This pane of the window displays all relevant sensor data from the Vaisala device If the IG04 BACnet Gateway is communicating correctly with the Vaisala device then you should see the Present Value data and a green check mark box under Statu...

Страница 15: ...figuration settings window Callout Vaisala device parameter Description 1 Baud Rate The baud rate at which the Vaisala device will communicate with the IG04 BACnet Gateway If the baud rate of the Vaisala device is changed the IG04 baud rate will be updated automatically to match the baud rate of the Vaisala device 2 Precipitation Reset This is the time of the day when the rain and hail counters wi...

Страница 16: ...ttings be configured as the last step since this will require you to modify the TCP IP address of your computer to be on the same network range as the IG04 BACnet Gateway in order to access the embedded web server System Tab Under the System tab you can configure or modify the following settings BACnet device name Device password There is no password configured by default but if a password is conf...

Страница 17: ...nce number BACnet Datalink protocol BACnet MS TP Settings Please note that the MS TP settings can only be modified if the BACnet Datalink is selected as MSTP Otherwise these settings cannot be modified and will be unaccessible Figure 13 Configure IG04 settings in FusionLIVE BACnet tab It is recommended to leave these settings at the default values as illustrated in Figure 13 below The default BACn...

Страница 18: ...me used for the Precipitation Reset setting Daylight Savings time Location used to create Sunrise Sunset data on the home page along with day night indication In order to adjust the Daylight Savings time you must first enable it by turning the Operation to ON You can then adjust the Start and Stop dates for Daylight Savings time Click on Apply to save your changes as illustrated in Figure 14 below...

Страница 19: ...tude coordinates required for the IG04 BACnet Gateway as illustrated in Figure 15 below Figure 15 Example latitude and longitude coordinates for Sunrise Sunset Selected Coordinates Latitude S 25 17 3 9759 Longitude E 151 28 46 1719 Latitude S 25 17 066264818981836 Longitude E 151 28 76953125 Latitude 25 28443774698303 Longitude 151 4794921875 Figure 16 Home page day night cycle when connected to V...

Страница 20: ...uter MUST be on the same network range as the IG04 BACnet Gateway in order to access the embedded web server If you change the IP address from the default settings in this step you will have to modify the IP address of your computer to be on the same network range as this new IP address Click on Apply to save your settings If you specify a different HTTP Port to the default 80 you will have to spe...

Страница 21: ... Innotech personnel Server IP Address only used when Maintenance Mode is set to Server or Client Server Port only used when Maintenance Mode is set to Server or Client Reboot Gateway Now Reboot the IG04 BACnet Gateway Figure 19 Configure IG04 settings in FusionLIVE Service Tab The Maintenance mode is a service tool for Innotech personnel only It MUST be set to Normal in order to view the data from...

Страница 22: ...nal help configuring your computer network settings and IG04 BACnet Gateway refer to DS99 05 Ethernet Setup Manual for Device Communications Cannot Connect to the Embedded Web Server Check that your Internet Explorer proxy settings are correct for the building network On some networks Internet Explorer proxy settings may require variations of the same address to operate on a network with a proxy s...

Страница 23: ...ou may need to restart Internet Explorer These error messages can appear occasionally on some computers Cannot launch Cannot find file Missing jnlp file Check that the JRE proxy settings are correct for the building network and are switched on Whilst these should be activated and inherited from Internet Explorer at launch of the JRE in some instances this field can be blank Enter the JRE proxy set...

Страница 24: ...with using its products At www innotech com au you can find technical manuals user instructions and data sheets for all our products For direct product support or product information contact your local distributor or an Innotech representative You can contact us via email phone or postal mail Website www innotech com au Email sales innotech com au Phone 61 7 3421 9100 Mail Innotech Control Systems...

Отзывы: