4.4 Battery Installation 
 

 

The batteries are 
housed inside the base 
of the meter.  The black 
cap on the bottom of the 
meter can be removed 
by pulling it straight off 
the end of the meter.  
The cap is just a press 
fit onto the meter. 

 

Please use care to pull the cap off the meter so that the bottom of the 
meter is pointing upward.  This will keep the batteries from falling out 
of the meter once the cap comes free and putting extra stress on the 
battery holder wires.  The meter requires two (2) N size alkaline 
batteries which are available at any drug store.  Place both new 
batteries in the battery holder following the polarity indication marked 
on the holder (negative end towards the spring).  Place the rubber 
retaining ring around the batteries once they are in the holder as 
shown in Fig. 4.  Then place the battery holder back into the end of 
the meter and replace the black cap and press it firmly back onto the 
meter. 

 

When the meter’s batteries need replacing, the meter will show “Lo b” 
on the LCD display after the meter is turned on.  If this message is 
displayed, the batteries should be replaced as described above. 

 

5.0 Trouble Shooting 

 

The Spray Calibrator measures the flow rate by measuring the time it 
takes to fill the meter’s tube.  The rising water level is sensed by 3 
electrodes in the meter.  The meter will only function with fluids that 
conduct electricity, such as water.  In the case of distilled water, the 
conductivity may be too low for proper meter operation.  All tap water 
will work very well with the meter.  Any substance that coats or covers 
the exposed metal on the electrodes will hinder their ability to sense 
the water level.  Care should be taken to rinse the meter inside and 
out with clean tap water when measurements are complete.  This will 
keep any foreign material from building up on the electrodes.  
Complete rinsing will also keep the diffuser pad from becoming 
clogged and therefore hindering the flow of water into or out of the 
meter during operation. 

 

Fig. 4 

 

7

6.0 Warranty & Service

 

 

 

One Year Warranty 

 

Innoquest, Inc. warrants this product to be free from defects in 
materials and workmanship under normal use and service for a period 
one (1) year from date of purchase.  This warranty extends only to the 
original purchaser and shall not apply to any product which, in 
Innoquest’s sole opinion, has been subject to misuse, alteration, 
abuse, or abnormal conditions of operation or handling.  Innoquest’s 
obligation under this warranty is limited to repair or replacement of the 
product which is returned to Innoquest.  Innoquest accepts no liability 
for whatever damages may be caused by a malfunctioning product. 

 
 

Repair & Service Policy

   

 

Product returned to Innoquest for repair or service must follow the 
guidelines set forth as follows:  Return of the product for warranty or 
service repair will be the responsibility of the purchaser (Innoquest 
does not pay inbound shipping charges).  All returns must receive an 
RMA number by 

calling

 Innoquest prior to return of the product.  The 

RMA number must be clearly marked on the outside of the shipping 
carton.  If the customer is returning product for non-warranty related 
repair or service, a minimum charge will apply for accessing the 
product’s repair needs and further work will not be completed without 
the customer’s approval. 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

910 

Hobe 

Road 

    

Woodstock, IL 60098 

 

 

 

Toll Free: 800-637-1623 
Phone: 815-337-8555 
Fax: 815-337-8556 
[email protected] 
www.innoquestinc.com 

   

Содержание SpotOn SC-4

Страница 1: ... 2 Features 2 2 0 Specifications 3 3 0 CE Declaration 3 4 0 General Meter Operation 4 4 1 Taking a Measurement 4 4 2 Turning the Meter Off 5 4 3 Changing Measurement Units 5 4 4 Installing the Batteries 6 5 0 Trouble Shooting 6 6 0 Warranty Service 7 7 0 French Instructions Instructions français 8 ...

Страница 2: ...z min 0 01 L min to 9 99 or 0 1 L min 10 0 up Battery two 2 N size alkaline batteries Battery Life 2 years meter has low battery indicator Size 10 0 in 25 4cm tall by 4 0 in 10 2cm diameter Weight 1 2 lbs 544 g weight Construction Break resistant plastic stainless steel Country of Origin Made in USA 3 0 Declarations CE Declaration of Conformity Innoquest Inc 910 Hobe Road Woodstock IL 60098 USA Ef...

Страница 3: ... meter and re press the START button to ready it for a new measurement Fig 1 Fig 2 Fig 3 5 PLEASE NOTE The most accurate measurements are made with the meter held at a slight angle to vertical as seen in Fig 1 This keeps the water flowing down into the meter along the back side of the meter and keeps it from accidentally falling on and triggering the meter s sensors 4 2 Turning the Meter Off The m...

Страница 4: ...bility to sense the water level Care should be taken to rinse the meter inside and out with clean tap water when measurements are complete This will keep any foreign material from building up on the electrodes Complete rinsing will also keep the diffuser pad from becoming clogged and therefore hindering the flow of water into or out of the meter during operation Fig 4 7 6 0 Warranty Service One Ye...

Страница 5: ...rrer Fig 1 Fig 2 Fig 3 9 VEUILLER NOTER les mesures les plus précises sont réalisées avec le calibreur maintenu avec un léger angle de la verticale comme sur la Fig 1 Ceci permet au flux de s écouler plus lentement dans I appareil et empêche tout déclenchement intempestif des capteurs du calibreur Arrêter le calibreur L appareil sera mis en route chaque fois que l on presse sur la touche START Le ...

Страница 6: ...oivent être remplacées comme Problèmes de fonctionnement Le calibreur mesure le débit en comptant le temps nécessaire au remplissage du tube II y a 3 électrodes dans le tube qui décèlent l élévation du niveau de I eau Le calibreur ne fonctionne qu avec des fluides qui conduisent le courant comme par exemple I eau Dans le cas d utilisation d eau distillée celle ci présente une trop faible conductiv...