Innoquest SpotOn SC-4 Скачать руководство пользователя страница 1

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Product Manual 

Innoquest Item # 

24200

 

 

1

 

Table of Contents 

 
 

1.0 Introduction……………………………...... 2 

 

1.1 Meter Diagram ………………………. 2 

 1.2 

Features………………………………. 

 
2.0 Specifications…………………………….. 3 
 
3.0 CE Declaration……………………………. 3 
 
4.0 General Meter Operation………………... 4 

 

4.1 Taking a Measurement……………… 4 

 

4.2 Turning the Meter Off……………….. 5 

 

4.3 Changing Measurement Units……… 5 

 

4.4 Installing the Batteries………………. 6 

 

5.0 Trouble Shooting…………………………. 6 
 
6.0 Warranty & Service………………………. 7 

 

7.0 French Instructions

(

Instructions français

)

… 

8

 

 
 
 
 
 
 

 
 
 

Содержание SpotOn SC-4

Страница 1: ... 2 Features 2 2 0 Specifications 3 3 0 CE Declaration 3 4 0 General Meter Operation 4 4 1 Taking a Measurement 4 4 2 Turning the Meter Off 5 4 3 Changing Measurement Units 5 4 4 Installing the Batteries 6 5 0 Trouble Shooting 6 6 0 Warranty Service 7 7 0 French Instructions Instructions français 8 ...

Страница 2: ...z min 0 01 L min to 9 99 or 0 1 L min 10 0 up Battery two 2 N size alkaline batteries Battery Life 2 years meter has low battery indicator Size 10 0 in 25 4cm tall by 4 0 in 10 2cm diameter Weight 1 2 lbs 544 g weight Construction Break resistant plastic stainless steel Country of Origin Made in USA 3 0 Declarations CE Declaration of Conformity Innoquest Inc 910 Hobe Road Woodstock IL 60098 USA Ef...

Страница 3: ... meter and re press the START button to ready it for a new measurement Fig 1 Fig 2 Fig 3 5 PLEASE NOTE The most accurate measurements are made with the meter held at a slight angle to vertical as seen in Fig 1 This keeps the water flowing down into the meter along the back side of the meter and keeps it from accidentally falling on and triggering the meter s sensors 4 2 Turning the Meter Off The m...

Страница 4: ...bility to sense the water level Care should be taken to rinse the meter inside and out with clean tap water when measurements are complete This will keep any foreign material from building up on the electrodes Complete rinsing will also keep the diffuser pad from becoming clogged and therefore hindering the flow of water into or out of the meter during operation Fig 4 7 6 0 Warranty Service One Ye...

Страница 5: ...rrer Fig 1 Fig 2 Fig 3 9 VEUILLER NOTER les mesures les plus précises sont réalisées avec le calibreur maintenu avec un léger angle de la verticale comme sur la Fig 1 Ceci permet au flux de s écouler plus lentement dans I appareil et empêche tout déclenchement intempestif des capteurs du calibreur Arrêter le calibreur L appareil sera mis en route chaque fois que l on presse sur la touche START Le ...

Страница 6: ...oivent être remplacées comme Problèmes de fonctionnement Le calibreur mesure le débit en comptant le temps nécessaire au remplissage du tube II y a 3 électrodes dans le tube qui décèlent l élévation du niveau de I eau Le calibreur ne fonctionne qu avec des fluides qui conduisent le courant comme par exemple I eau Dans le cas d utilisation d eau distillée celle ci présente une trop faible conductiv...

Отзывы: