Innoquest SpotOn 29360 Скачать руководство пользователя страница 4

 

3.0 Features 

 

 

Meets ASABE S313.3 Soil Compaction Standard 

 

 

Automatically displays maximum compaction value when 
probe is extracted from the soil. 

 

 

Color coded display for easy compaction reference 

Green 0-200 PSI (0-1400 kPa) 
Yellow 200-300 PSI (1400-2070 kPa) 
Red 300+ PSI (2070+ kPa) 

 

 

The high resolution of the electronic force sensor assures 
accurate compaction values in soft soils with 1/2in.(12mm) 
cone. 

 

 

Measurements can be displayed in PSI or kPa 

 

 

Rugged design & rubber protector for repeated field use 

 

 

Stainless steel shaft with depth marking every 4in.(10cm) 

 

 

Ultra-hard tool steel cone for years of service 

 

 

Made in USA 

 

4.0 Specifications 

 

Usable Probe length:

 30in. (76cm) 

 

Range:

 0 to 825 PSI (0 to 5690 kPa)  

 

Resolution:

 1 PSI (7 kPa) 

 

Accuracy:

 +/- 15 PSI (100 kPa) 

 

Waterproof:

 IP64 rating (Dust Tight/Splash Resistant) 

 

Meter Size:

 35in.(89cm) x 11in.(28cm) x 3in.(7.6cm) 

 

Shipping Box Size:

 37in.(94cm) x 13in.(33cm) x 5in.(13cm) 

 

Battery:

 Two (2) AA (LR6) Size Alkaline Batteries (1 year battery life) 

 

Weight:

 1.9 lbs. (.6 kg) weight 

 

Environmental:

   Use: 32-120°F (0-49°C) / 0-100% RH 

 

Storage: 0-130°F (-18-55°C) / 5-90% RH 

 

Construction:

 Solid Machined Plastic Body, Aluminum Handle, 

Stainless Steel Shaft, Hardened Tool Steel Tip 

 

Cone Size:

 0.505in.(12.8mm) Diameter / 30° Included Angle 

 

Country of Origin:

 USA 

Содержание SpotOn 29360

Страница 1: ...Product Manual Innoquest Item 29360 Digital Soil Compaction Meter ...

Страница 2: ...atures 3 4 0 Specifications 3 5 0 General Operation 4 5 1 Installing the Batteries 4 5 2 Zero Calibration 4 5 3 Changing Display Units 5 5 4 Taking a Reading 5 5 5 Probe Tip Cover 6 5 6 Probe Tip Replacement 6 6 0 Troubleshooting Maintenance 6 7 0 Warranty Service 7 ...

Страница 3: ... sharp metal tip could cause damage to packaging containers or personal Always use the included tip cover when transporting the meter See section 5 5 for more info 2 0 Meter Diagram Stainless Steel Shaft with Depth Marks Splash Dust Proof Digital Display Extra Hard Tool Steel Tip Replaceable Battery Compartment In Handle Power Button Zero Button Color Coded Bar Graph Display ...

Страница 4: ...ft with depth marking every 4in 10cm Ultra hard tool steel cone for years of service Made in USA 4 0 Specifications Usable Probe length 30in 76cm Range 0 to 825 PSI 0 to 5690 kPa Resolution 1 PSI 7 kPa Accuracy 15 PSI 100 kPa Waterproof IP64 rating Dust Tight Splash Resistant Meter Size 35in 89cm x 11in 28cm x 3in 7 6cm Shipping Box Size 37in 94cm x 13in 33cm x 5in 13cm Battery Two 2 AA LR6 Size A...

Страница 5: ...Press the ZERO button and continue holding the meter steady and above the ground until the zero function completes and the LCD displays a 0 value The compaction meter should show a zero value when suspended in air prior to taking a probing with the meter Temperature changes battery voltage changes and rough handling can cause shifts in the meter s zero point All the above variations are easily and...

Страница 6: ...sult of side loading on the shaft Penetration Rate ASABE Engineering Practice EP542 recommends a Penetration Rate of 1 2 in second 30mm sec for best accuracy Maximum Reading Display The maximum compaction reading attained during the penetration will automatically display as the probe is withdrawn from the soil The display will show HI followed by the maximum compaction reading This reading will sh...

Страница 7: ...ttached with removable type thread locker so some force may be required to loosen it The probe tip should be replaced when the diameter of the cone s base measures less than 0 490in 12 45mm diameter 6 0 Troubleshooting Maintenance Errors If an error message Err2 or Err3 is displayed during the zero process then retry the zero button and assure the meter s shaft and tip are hanging vertically below...

Страница 8: ...ed to Innoquest for repair or service must follow the guidelines set forth as follows Return of the product for warranty or service repair will be the responsibility of the purchaser Innoquest does not pay inbound shipping charges All returns must receive an RMA number by calling Innoquest prior to return of the product The RMA number must be clearly marked on the outside of the shipping carton If...

Отзывы: