Allow the Heat Sensor to reach room temperature before use. The power
to the cooker must be switched off (at the consumer unit). See the table
below for the mounting location and follow instructions 1–5.
Starting the Sensor
Insert the battery and place the
Heat Sensor on the installation
plate. Press the button shortly.
(LED flashes green).
Set sensitivity level
Set the sensitivity level according to the mounting height (as described
in the table) by evenly pressing the Sensor's button. The Heat Sensor's
sensitivity level must be always adjusted when installing it to the ceiling.
Please refer to the table underneath together with the information on page
18, alternatively watch the film on sensitivity configuration).
DISTANCE FROM COOKER TO HEAT SENSOR
SENSITIVITY LEVEL CONFIGURATION
Mounting height above the
cooker
0–36" (0–90cm) wide cooker
Sensitivity
Number of
"beep(s)"
64"–80" (160–200cm)
Recommended: Immediately above
the middle of the cooker.
Alternatively: Farther out into the
room with bracket. See the bracket
package for mounting instructions.
1 press
2 presses
Mounting height above the
cooker
0–36" (0–90cm) wide cooker
56"–63" (140–159cm)
Recommended: Immediately above
the middle of the cooker.
Alternatively: Farther out into the
room with bracket. See the bracket
package for mounting instructions.
Please note: the sensitivity level of the Sensor is confirmed by the appropriate sound pattern sequence only and not the LED flashes.
CEILING MOUNTING
WITH IR LENS EX TENSION
3
4
11
Watch the film:
https://vimeo.com/321503955
Setting sensitivity
Watch the film:
https://vimeo.com/321502592
Sensor installation
Содержание SGC430-1U3-50