background image

ibwellness.com

 Chair Manual

20

19

Trouble Shooting

You may experience the following noises or feeling when in massage, as being 

due to the mechanical design, they will not have any effect on the operation of 

the unit and the product life.
• A “clatter” noise occurs when the knead balls go up and down.
• A “creak” noise of the gear and the motor occurs while in massage.
• A friction noise occurs when the knead balls rub the cover cloth.
•  A rattling noise occurs while in the “Tap” or “Knead and Tap” massage 

movements (particularly when the massage moves from the shoulders to  

the back).

•  In the “Knead”, “Tap”, or “Knead and Tap” massage movements, massaging 

speed may vary with the knead balls’ strength changed.

• A roaring noise of the motor occurs when load is given to the chair.
•  A “cuckoo” noise occurs while in the auto mode course, the knead balls are 

automatically adjusted to the back-and-forth position to have the chair fitting in 

with the user’s body shape.

•  The compressor’s noise and the air exhausting noise occur while in  

air-massage.

• A noise occurs when the air bag is inflated.

• A noise occurs while in massage of the shoulders.
• A grinding noise occurs when the backrest is reclined.
• There is a humming sound from the pump.

Warning

 Absolutely do not modify, disassemble or repair by yourself. Negligence may cause fire or mechanical 

trouble of the chair which may result in hazard on the body.

Avertissement 

Évitez absolument de modifier, de démonter ou de réparer le fauteuil vous-même. La négligence peut 

entraîner un incendie ou des troubles mécaniques du siège et poser un risque de blessures.

Maintenance

-  Turn off and unplug the chair 

 

before cleaning. 

-  Use a dry, neutral colored cloth or 

soft bristled brush to lightly wipe  

the chair.

-  Do not use water or any other 

liquids to clean the chair.

Any other servicing should be 

performed by an authorized 

service representative

Содержание Jin

Страница 1: ...this user manual thoroughly prior to operating the massage chair Please keep this manual for future reference by inner balance A Division of Johnson Health Tech NA 1600 Landmark Drive Cottage Grove WI...

Страница 2: ...listed in this user manual prior to use Basic precautions should always be used when operating an electrical appliance Safety Instructions 3 6 Product Specifications 7 Hardware Pack Contents 7 Produc...

Страница 3: ...product must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a...

Страница 4: ...e When using an electrical appliance basic precautions should always be followed including the following Read all instructions before using this appliance DANGER To reduce the risk of electric shock A...

Страница 5: ...l Backrest Cushion Shoulder Airbags Product Specifications Description Specifications Product Name Massage Chair Model No Jin Rated Voltage AC 110V Rated Frequency 60Hz Rated Power Consumption 230W Di...

Страница 6: ...e panels from the carton and take them out to begin assembly b Connect the side panel airhose with the airhose coming out of the side of the chair Both sides of the airhose need to be inserted in orde...

Страница 7: ...shoulder airbags Locating pin Locating pin hole Cross screw Cross screwdriver Press Press Lift Lift Shoulder position adjustment K e e p t h i s a c t i o n a d j u s t u p o r d o w n Finished Should...

Страница 8: ...D RECLINE BUTTONS Backrest Down Backrest Up Before Use 4 Adjust the position of the headrest Adjust the under part of the headrest and align it with the position of the ear 1 Make sure that the produc...

Страница 9: ...apping Whole Dual Whole Shiatsu Whole Massage Whole Off Kneading Point Tapping Point Dual Point Shiatsu Point Massage Point Off Operation Guide FUNCTION DESCRIPTION OF CONTROLLER BUTTONS Zero G1 Zero...

Страница 10: ...g with wet hands Operation Guide DISPLAY DIAGRAM 1 Power is on 2 Massage chair is scanning the users back contour to provide a massage experience customized for the user 3 Scanning is complete and the...

Страница 11: ...e automatically adjusted to the back and forth position to have the chair fitting in with the user s body shape The compressor s noise and the air exhausting noise occur while in air massage A noise o...

Страница 12: ...power and stop the operation Restart the unit after 30 min break The rated operating time has elapsed The power indicator fails to light up after the power switch is turned on Check whether there is...

Отзывы: