H07 

Control Duration

 

U07 

Finished Alarm of Stage 

 

S08 

Stage 8 Temperature Set 

Value

 

H08 

Control Duration

 

U08 

Finished Alarm of Stage 

 

S09 

Stage 9 Temperature Set 

Value

 

H09 

Control Duration

 

U09 

Finished Alarm of Stage 

 

S10 

Stage 10 Temperature 

Set Value

 

H10 

Control Duration

 

U10 

Finished Alarm of Stage 

 

S11 

Stage 11 Temperature 

Set Value

 

H11 

Control Duration

 

U11 

Finished Alarm of Stage 

 

S12 

Stage 12 Temperature 

Set Value

 

H12 

Control Duration

 

U12 

Finished Alarm of Stage 

 
 
 
 
 
 
 

 

 

 

 

ITC-310T

Inkbird Tech. Co., Ltd.                                                                        www.ink

12 

Control Duration 

10 

Finished Alarm of Stage 

Stage 8 Temperature Set 

Value 

25.0

 or 77.0

 

Control Duration 

10 

Finished Alarm of Stage 

Stage 9 Temperature Set 

Value 

25.0

 or 77.0

 

Control Duration 

10 

Finished Alarm of Stage 

Stage 10 Temperature 

Set Value 

25.0

 or 77.0

 

Control Duration 

10 

Finished Alarm of Stage 

10 

Stage 11 Temperature 

Set Value 

25.0

 or 77.0

 

Control Duration 

10 

Finished Alarm of Stage 

11 

ge 12 Temperature 

Set Value 

25.0

 or 77.0

 

Control Duration 

10 

Finished Alarm of Stage 

12 

310T User Manual

 

Inkbird Tech. Co., Ltd.                                                                        www.ink-bird.com

 

 

Note 6.2.6 

 

 

Note 6.2.6 

 

 

Note 6.2.6 

 

 

Note 6.2.6 

 

 

Note 6.2.6 

 

 

Note 6.2.6 

Содержание ITC-310T-B

Страница 1: ...User Manual Version 1 0 Inkbird Tech Co Ltd 2016 Inkbird Tech Co Ltd All rights reserved No part of this document may be reproduced Inkbird has made every effort to ensure that the information contai...

Страница 2: ...ture Set Values 6 2 7 Cycle and Auto Mode MD AT 7 Error Description Sensor fault alarm 8 Technical Assistance and Warranty 8 1 Technical Assistance 8 2 Warranty ITC 310T Inkbird Tech Co Ltd www ink 2...

Страница 3: ...in injury due to electric shock Do not allow pieces of metal wire clippings or fine metallic shaving or filings from on to enter the product Doing so may occasionally result in electric shock Do not u...

Страница 4: ...control heating pump constant temperature cycle strain culture fermentation seed sprouting electric temperature protection and automatic temperature control ectrical equipment etc product with dual r...

Страница 5: ...0 0 70 2 58 158 On Off Control Heating and Cooling 1 999 min hr 1 90 day 24hour 1 7s Max 12 periods 1 999 times cycle or 00 infinite cycle 100 240VAC 50Hz 60Hz Current Max 10A Voltage 100 240V AC Powe...

Страница 6: ...ge of the operating Under setting mode press this DOWN button can ng value Under running mode when TR 1 or 2 press this button can view the Under setting mode press this UP button can increase the set...

Страница 7: ...eturn to normal temperature displaying mode after 3 seconds 5 2 How to Set Parameters When controller works normally press and hold SET key for more than 3 seconds to ify parameter mode SET indicator...

Страница 8: ...Inkbird Tech Co Ltd www ink 5 3 Setup Flow Chart ITC 310T Inkbird Tech Co Ltd www ink 8 310T User Manual Inkbird Tech Co Ltd www ink bird com...

Страница 9: ...ink 9 nstruction perature Control Setting When setting temperature in Centigrade Function Setting Range Default Setting Temperature Set Value 50 0 120 25 0 Heating Differential Value 0 3 15 0 2 0 Cool...

Страница 10: ...Default Sett Time Unit Setting D H M D Cycle Setting Mode 0 999 1 Auto Mode 0 or 1 0 Stage Setting Value 1 12 1 Start Stage Setting Value 1 12 1 Function Setting Range Default Setting emperature Set...

Страница 11: ...ch Co Ltd www ink 11 menu codes as below chart Function Default Setting Stage 1 Temperature Set Value 25 0 or 77 0 Same setting range as TS Control Duration 10 Finished Alarm of Stage 1 n Stage 2 Temp...

Страница 12: ...Alarm of Stage ITC 310T Inkbird Tech Co Ltd www ink 12 Control Duration 10 Finished Alarm of Stage 7 n Stage 8 Temperature Set Value 25 0 or 77 0 Control Duration 10 Finished Alarm of Stage 8 n Stage...

Страница 13: ...when measured temperature PV TS Temperature Set light off heating relay stop working For example Set TS 25 0 CD 2 0 HD 3 0 if measured temperature 27 0 TS CD cooling will turn on if measured temperatu...

Страница 14: ...Value TS1 Cooling Differential Value CD then cooling on with cooling indicator light on and cooling relay start working NOTE The control duration of each stage start timing only when the current tempe...

Страница 15: ...6 37 38 39 ITC 310T Inkbird Tech Co Ltd www ink 15 30 2 22 30 2 24 30 2 26 32 3 28 34 3 30 35 3 30 35 3 30 35 3 30 35 3 30 35 3 30 35 3 30 35 3 32 35 3 34 35 3 35 35 3 35 35 35 35 35 35 35 35 35 35 35...

Страница 16: ...eached the set temperature of current stage and total time of 5 14 19 25 and 6 2 2 Alarm High Low Limit Setting AH AL When measured temperature PV AH alarm with BI BI BIII sound until the AH or press...

Страница 17: ...When TR 0 timer function will be off there will not display the other set values follow TR and no need to set hem when TR 1 or TR 2 timer function will be activated user can set the time and the cont...

Страница 18: ...y in every 2 seconds with all output control turned off only by pressing any button will go to next stage control 6 2 7 Cycle and Auto Mode MD AT the operation time of timer and temperature set values...

Страница 19: ...tat for one years from the date of purchase when operated under normal condition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty i...

Отзывы: