HOW TO SET

OPERATING 

INSTRUCTION

In normal working status, press and hold “

” key for more than 3s to turn off the controller; in Power-off Status, press and hold

” key for more than 1s to turn on the controller.

In normal working status, screen displays the current measuring value, the controller switch modes between heating and cooling

automatically.

If the measuring temperature ≥ temperature set value + difference set value, the controller starts refrigerating, the cool indicator

lamp lights on, and the refrigerating relay is connected. When cool indicator lamp flashes, indicating that the refrigerating device is
under compressor delay protecting status.

If the measuring temperature ≤ temperature set value, the cool indicator lamp turns off, and the refrigerating relay is disconnected.

If the measuring temperature ≤ temperature set value - difference set value, the controller starts heating, the heat indicator lamp

lights on, and the heating relay is connected.

If the measuring temperature ≥ temperature set value, the heat indicator lamp turns off, and the heating relay is disconnected.

8

of

15

Contact Us

Email: [email protected]  ,  www.ink-bird.com 
INKBIRD Tech. C. L.

Содержание ITC-1000

Страница 1: ...d is a home automation brand operating around the globe We specialize in thermostat and lighting control system products INKBIRD ITC 1000 TEMP CONTROLLER Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L ...

Страница 2: ...W TO WIRE Wire diagram 1 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L IMPORTENCE Please don t forget to wire the Heating and Cooling device to Power supplier and make a circuit ...

Страница 3: ...HOW TO WIRE SAMPLES Tools and Materials ITC 1000 ABS project box Power cords and wires Power Socket Terminal Block 2 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L ...

Страница 4: ...HOW TO WIRE SAMPLES 3 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L Attach wires to terminal block ...

Страница 5: ...HOW TO WIRE SAMPLES 4 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L Fit to ITC 1000 ...

Страница 6: ...HOW TO WIRE SAMPLES 5 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L Sample from our customer ...

Страница 7: ...On and Off Confirm the Setting Value Save and Exit Function C F Display Degrees Celsius or degrees Fahrenheit PV SV Display Display Process Value Set Value and Parameter Menu Set Indicator Lamp On Parameter Setting Status Heat Indicator Lamp On Heating Start Off Heating Stop Cool Indicator Lamp On Refrigerating Start Off Refrigerating Stop Flash Compressor Delay Left lamp Right lamp Contact Us Ema...

Страница 8: ...o enter the parameter setting of current menu the parameter value starts to flash Press key or key to adjust the parameter value of current menu After the set press key to exit the parameter setting of current menu the parameter value stops to flash User can set the other functions as above steps In any status press key to save the parameter modified value and return to the normal temperature valu...

Страница 9: ...lamp lights on and the refrigerating relay is connected When cool indicator lamp flashes indicating that the refrigerating device is under compressor delay protecting status If the measuring temperature temperature set value the cool indicator lamp turns off and the refrigerating relay is disconnected If the measuring temperature temperature set value difference set value the controller starts hea...

Страница 10: ... C CF Fahrenheit or Celsius Setting C Code Function Set range Default Note TS Temperature Set Value 50 210 o F 50 o F Min Unit 1 o F DS Difference Set Value 1 30 o F 3o F PT Compressor Delay 0 10 minutes 3 minutes CA Temperature Calibration Value 15 15 o F 0o F CF Fahrenheit or Celsius Setting F When the set temperature is degrees Celsius When the set temperature is degrees Fahrenheit Contact Us E...

Страница 11: ...TARGET Fahrenheit or Celsius Setting F CF Target Temperature 75 85 TS DS Compressor Delay 2 minutes PT Temperature Calibration Value 2 CA 10 of 15 SAMPLE Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L ...

Страница 12: ...ore than 3s to enter set mode Press key once and the screen shows CF code ENTER CF MODE Press Key to enter CF setting use key or key choose F Press key to confirm and continue to setting CHOOSE F 11 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L ...

Страница 13: ...se TS code ENTER TS MODE Press Key to enter TS setting use key or key choose 80 Press key to confirm and continue to setting CHOOSE 80 12 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L SAMPLE Press key and choose DS code ENTER DS MODE Press Key to enter DS setting use key or key choose 5 Press key to confirm and continue to setting CHOOSE 5 ...

Страница 14: ...minutes Press key to choose PT code ENTER PT MODE Press Key once to enter PT setting use key or key choose 2 Press key to confirm and continue to setting CHOOSE 2 13 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L ...

Страница 15: ...nce to enter CA setting use key or key choose 2 Press key to confirm and continue to setting CHOOSE 2 14 of 15 Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L IMPORTENCE after setting don t forget to press key to save the parameter modified value and return to the normal temperature value ...

Страница 16: ...Since 2010 INKBIRD has enjoyed years of continuous growth thanks to millions of satisfied customers around the world At INKBIRD We look into the latest innovations and find products that can connect with our daily life ideas that can make our routine tasks easier technologies that truly enhance our activities 15 of 15 Email cs ink bird com Website www ink bird com INKBIRD Tech C L Contact Us Email...

Страница 17: ...THANK YOU Contact Us Email cs ink bird com www ink bird com INKBIRD Tech C L ...

Отзывы: