11
.Set the mode of
OVEN /SMOKER/BARBE-
CUE
(1)
The customer can select P1, P2, P3 or P4 to test
and monitor the temperature inside the oven,
smoker or grill.
(2)
Short press “PROBE ”button to select P1, P2, P3
or P4 mode, and press “MEAT ”button to select
“OVEN ”mode. Or press OVEN/°C/°F to enter OVEN
mode directly.
(3)
At this time, display the symbol
SET TEMP
,
“HI”temperature and“LO”temperature are alternate
-
ly displayed at a frequency of 0.5 Hz. It will
automatically exit after 10 seconds and current
temperature will be displayed .
(4)
Short press OVEN/°C/°F
button
,
SET TEMP
is
on,“HI”flashes, indicate that it enters the“HI”or“
LO”temperature state setting. At this time, press
▲
or
▼
to increase or decrease the“HI”temperature.
Moreover long press
▲
or
▼
to increase or
decrease the“HI”temperature quickly. Then short
press OVEN/°C/°F
to confirm“HI”and select“
LO”temperature setting,“ LO” will flash, at this time,
press
▲
or
▼
to increase or decrease the“ LO”tem
-
perature, long press
▲
or
▼
to increase or decrease
the“ LO”temperature quickly.
effect to press .
(2)
Press to enter the time setting state,at this
time the screen of hour time flashes, then short
press
▲
or
▼
to set the time of hour, long press
▲
or
▼
to quickly set the time of hour. Furthemore,short
press to confirm the setting time of hour. Next
the time of minute flashes, short press
▲
or
▼
to
set the time of minute , long press
▲
or
▼
to quickly
set the time of minute, then press again to
confirm the time of minute and it will start counting
down. The maximum countdown setting time is 99
hours and 59 minutes.
Note: The countdown cannot be set to 00:00, and
the minimum is 00:01.
(3)
When the countdown is running or paused, long
press for 2 seconds to restore the default
countdown.
(4)
When the countdown is running, the symbol
flashes, if pressing , the countdown will pause
and the symbol will stop flashing.
(5)
When the countdown time reaches 00:00, it will
flash and the backlight is on,also the buzzer sounds
3 times in 0.5 second, after a pause of 0.5 second, it
will continue to sound which will last for one minute.
Then it restores the countdown time. Or press any
button to turn off the backlight, the buzzer stops and
the countdown time is restored.
battery symbol flashes, the current temperature
displays “Lo”, all functions are turned off, and the
user is warned that the transmitter cannot be used
normally until the product is charged .
When the receiver receives a low power alarm from
the transmitter , indicates that battery power
only has 1 bar left at the transmitter. When the
receiver battery symbol flashes, the temperature
screen shows“Lo” , all functions are turned off, and
the user is warned that the receiver
cannot be used
normally until the product is charged
Regardless of the transmitter or the receiver, as
long as they are charged by USB port, the charging
indicator lights will be on, and the charging
symbol of the LCD will be on too, and the power
symbol shows the corresponding power. When fully
charged, the full indicator light will be on. The
product can also be used during the charging
process.
8
. Auto Power Off Func-
tion
If there is no data received from the transmitter for
more than 30 minutes, buzzer will alarm with a
beep sound in every two seconds, and then
alarming will automatically turn off after one
minute and close all the functions. When in
alarming, press any button to stop the beep and
- In the power-on state
,
short press to
select the display temperature °C or °F. Long press
2 seconds to shut down; In the off state, short
press to power on or long press 5 seconds to power
on and enter the pairing state.
●
Power by single section lithium battery and
rechargeable.When charging this product, the
adapter standard output should be USB5V, and the
output current should higher than 500mA.
●
Probe temperature range: 0-300 C°/32° F ~ 572 °
F(Short-time measurement);0-250/ C°32° F~ 482 °
F (continuous monitoring)
●
Range of Error
:
5
.Synchronous Transmit-
ter and Receiver
Normally, there is no need to synchronize the
transmitter and receiver, as we have already done
this at the factory. It only need to turn on the
transmitter and receiver and wait for a dozen
seconds to see the real-time temperature displayed
on the transmitter and receiver.
However, in some special cases, if the transmitter
and receiver are not matched, the following steps
can be used to implement the matching function:
(1)
When the receiver is in the starting state, long
press the PROBE button of the receiver for 2
seconds to enter the matching mode, showing“- -
-” and flashing
(2)
Long press the transmitter for 2
seconds to shutdown state, and then long
press for 5 seconds, the power will be
turned on and enter the code matching state, and
the temperature screen flashes at 0.5Hz frequency.
(3)
Short press the transmitter
button or
wait for 10 seconds to send data. If the matching is
successful, the transmitter temperature. screen will
stop flashing, the receiver will display the received
temperature; if no data is received from the
transmitter, after 60 seconds, it will exit the
matching mode and the matching is unsuccessful.
Note: When matching the code, the transmitter and
receiver are required to be placed in short distance,
which cannot exceed 30CM.
6
. Failure Connection
Alarm of Transmitter and
Receiver
The wireless product can reach 500meters/1500
feet in the exposed place. If the receiver exceeds
the receiving range, the abnormal external interfer-
ence or turn off the transmitter, the receiver can not
receive the data from the transmitter. If this
situation continues for more than 1 minutes, the
receiver will Beep to indicate that the connection
fails, and displays”---”at the same time. Then move
the receiver closer to the transmitter, the connec
-
tion will automatically recover and the receiver will
display the current temperature.
7
. Low Voltage Alarm and
Charging Function of
Transmitter and Receiver
The transmitter battery symbol indicates the
state of charge. When the battery power has only 1
bar left, low power will be sent to receiver. When the
cancel auto off function
9
. Measure the Tempera-
ture of the Cooking
Degree for Meat
(1)
Four probes (P1
、
P2
、
P3 and P4) can be used
to measure temperature of four pieces of meat or
different positions of a large piece of meat, press
the“PROBE”button to select a P1, P2, P3 or P4. The
corresponding symbol
SET TEMP
of the selected
probe lights up. If there is no operation after 10
seconds, it will automatically exit, the symbol
SET
TEMP
will be off, and the current temperature will
be displayed.
(2)
Press “MEAT ”button to select meat type
:
PROG
(Program-User self-defined)
,
GBEFF(Ground
Beef)
,
GPOUL(Ground Poultry),BEEF,VEAL,CHCKE
(Chicken),PORK,POULT(Poultry),LAMB &FISH
。
(3)
Short press “TASTE”to select the cooking degree
of meat
:
RARE,MED RARE,MEDIUM, WELL and
DONE
。
(4)
Once the P1, P2, P3 or P4 probe detects that the
temperature of the meat reaches the cooked
temperature, the corresponding current temperature
of the receiver flash at a frequency of 1 Hz, the
buzzer sounds 3 times in 0.5 second, after a pause
of 0.5 second, it will continue to sound which will
last for one minute
,
and the backlight will be on.
Press any button to stop the buzzer and turn off the
backlight.
10
. Set the Temperature
of Your Personal Taste
(1)
Short press the“PROBE”button to select the P1,
P2, P3 or P4 mode, the corresponding symbol
SET
TEMP
of the selected probe lights up. If there is no
operation after 10 seconds, it will automatically exit,
the symbol
SET TEMP
will be off, and the current
temperature will be displayed. Short press
“MEAT ”to select PROG mode or press
▲
or
▼
to
enter PROG mode directly.
(2)
Press
▲
or
▼
to increase or decrease the setting
temperature. Long press
▲
or
▼
to rapidly increase
or decrease the temperature setting.
(3)
When the temperature of the P1, P2, P3 or P4
reaches the setting temperature, and the corre
-
sponding current temperature of the receiver flash
at a frequency of 1 Hz. The buzzer sounds 3 times
in 0.5 second, after a pause of 0.5 second, it will
continue to sound which will last for one minute
,
and the backlight will be on. Press any button to
stop the buzzer and turn off the backlight.
(5)
Press OVEN/°C/°F
again to confirm the“LO”tem-
perature, it will stop flashing and exit the HI/LO
setting temperature state.
(6)
Once the temperature of the P1, P2, P3 or P4
exceeds the temperature range of“HI”and“LO”, the
current temperature and the“HI”or” LO”,The
corresponding current temperature of the receiver
flashes at 1 Hz, then the buzzer will sound 3 times
in 0.5 second, after a pause of 0.5 second, it will
continue to sound which will last for one minute. At
this time the backlight will be on, users can press
any button to stop the buzzer and turn off the
backlight.
Note: The setting temperature of the“LO“cannot be
greater than or equal to the setting temperature of
“HI”.
Check the Setting Temperature of Current Probe
Mode
In the case where the symbol
SET TEP
is not
displayed, the customer only needs to tap the
PROBE, MEAT, TASTE, OVEN/°C/ ,
▲
or
▼
button to
query the setting temperature in the corresponding
probe mode.
12
.Countdown Mode
(1)
The default countdown time is 00:10. In the
setting state of the countdown time, there is no
C
4
. Button
-4-
Range of
Temperature
(T)Celsius
Celsius
Error
Range of
Temperature
(T) Fahrenheit
Fahrenheit
Error
0
°C<
=T
<20
°C
±
2
°C
32
°F <
=T
<68
°F
±
4
°F
20
°C<
=T
<200
°C
±
1
°C
68
°F <
=T
<392
°F
±
2
°F
200
°C<
=T
<250
°C
±
3
°C
392
°F <
=T
<482
°F
±
5
°F
250
°C<
=T
<300
°C
±
5
°C
482
°F <
=T
<545
°F
±
9
°F