background image

Air2-FD100 | © 2020 Inim Electronics S.r.l.

3

1.  Air2 system description

All anti-intrusion systems INIM can manage the two-way wireless system Air2 characterized by a MHz carrier

frequency 868 MHz.

The system components Air2 are:

 

Air2-BS200/50 transceiver module, 50 terminals

 

Air2-BS200/30 transceiver module, 30 terminals

 

Air2-BS200/10 transceiver module, 10 terminals

 

Air2-KF100 4 button remote-control key

 

Air2-Ergo 4 button remote-control key

 

Air2-Pebble 4 button remote-control key

 

Air2-MC200 magnetic contact with shock and tilt sensor in white or brown

 

Air2-MC300 magnetic contact with two I/O terminals, in white or brown

 

Air2-FD100 smoke detector

 

Air2-Aria/W keypad with graphic display

 

Air2-Hedera outdoor sounder, in white or chrome effect

 

Air2-Smarty/W indoor sounderflasher

 

Air2-DT200T dual technology curtain detector, in white or brown

 

Air2-XIR200W PIR detector, 12 m

 

Air2-XDT200W dual technology curtain detector

 

Air2-UT100 universal transceiver

 

Air2-ODI100W outdoor wireless dual-infrared detector

 

Air2-OTT100W outdoor wireless triple-technology detector

Technical specifications of the system Air2

Operating frequency

range

868.0 - 868.6 MHz

selectable channels

868.1, 868.3, 868.5 MHz

RF output power

25mW e.r.p.

Communication type

Two-way

Modulation

GFSK

Device supervision

from 12 to 250 minutes

/PUF

In order to comply with the EN 50131-1 standards the alarm system supervision time must be below 120 minutes.

Содержание Air2-FD100

Страница 1: ... JS 8JSFMFTT TNPLF EFUFDUPS E EN 50131 1 EN 50131 5 3 EN 50130 4 EN 50130 5 INCERT CEB T031 OTUBMMBUJPO BOE QSPHSBNNJOH NBOVBM ...

Страница 2: ...FD100 7 3 1 Enrolling a wireless device 7 3 2 Battery replacement 8 4 Programming wireless terminal 9 4 1 Wireless terminal parameters 9 4 2 Real time 9 5 General information 10 5 1 About this manual 10 5 2 Manufacturer s details 10 5 3 Notes from the Manufacturer 10 5 4 Simplified EU Declaration of Conformity 10 5 5 Documents for the users 11 5 6 WEEE 11 2 Installation and programming manual 100 ...

Страница 3: ...white or brown Air2 FD100 smoke detector Air2 Aria W keypad with graphic display Air2 Hedera outdoor sounder in white or chrome effect Air2 Smarty W indoor sounderflasher Air2 DT200T dual technology curtain detector in white or brown Air2 XIR200W PIR detector 12 m Air2 XDT200W dual technology curtain detector Air2 UT100 universal transceiver Air2 ODI100W outdoor wireless dual infrared detector Air...

Страница 4: ...ow to the sampling chamber UUFOUJPO Air2 FD100 is a smoke detector that can be used exclusively for the detection of smoke in the protected area With the use of Air2 FD100 the intrusion control system INIM cannot be considered a fire detection system The operating parameters of detectors can be changed and adapted to the environmental conditions either from the control panel orvia the programming ...

Страница 5: ...arts LJ Detector LJ LED red yellow green LJ Battery LJ Tampermicroswitch LJ ENROLL microswitch LJ Base LJ Mounting screw hole 2 2 Air2 FD100 technical specifications Battery type Lithium CR17450 3V estimated life 3 years Low battery fault voltage Less than 2 4V Current draw during standby 70µA ...

Страница 6: ...e included 114mm Weight base and battery included 182 g 2 3 LED signallings from Air2 FD100 The tricolourLED 360 visibility indicates the detectorstatus Green one flash every 15 seconds detector operating properly Green one flash every 40 seconds low battery Yellow On solid fault present Yellow flashing sampling chamber contaminated with dust etc Red On solid detector in alarm status 6 Installatio...

Страница 7: ...tector to the base turn it still further until notch A aligns with notch C in order to allow the base to close the tamper microswitch 7 Enroll the device 3 1 Enrolling a wireless device The enrolling procedure allows you to associate a wireless device INIM with the transceiver Air2 BS200 which acts in conjunction with the intrusion control panel This procedure varies depending on the control panel...

Страница 8: ...ceiver 3 Set the device as Wireless 4 Start the learning phase from the control panel 5 Press the ENROLL button on the wireless device 3 2 Battery replacement When changing the battery it is advisable to press the ENROLL button in order to be sure that the device is synchronized with the wireless transceiver 8 Installation and programming manual 100 DRAFT ...

Страница 9: ...the activation command Alarm pulses This is the number of pulses each lasting as long as the programmed Alarm pulse duration necessary to generate a zone alarm event If this value is more than 1 you must also program the Multi pulse time parameter Multi pulse time This parameter applies only when the Alarm pulse num is higher than 1 This is the window during which a number of alarm pulses must be ...

Страница 10: ... or replace the parts of this system have authorization to work only on devices marketed underthe brand Inim Electronics 5 3 Notes from the Manufacturer The devices Air2 are certified by IMQ Sistemi di sicurezza Italian certification body The information relating to the power supply batteries required by the devices Air2 are provided in the fol lowing Technical Specification table The manufacturer...

Страница 11: ...g new equipment of the same type You are also entitled to convey for disposal small electronic waste products with dimensions of less than 25cm to the premises of electronic retail outlets with sales areas of at least 400m2 free of charge and without any obligation to buy Appropriate differentiated waste collection for the subsequent recycling of the discarded equipment its treatment and its envir...

Страница 12: ...info inim biz _ www inim biz Via dei Lavoratori 10 Loc Centobuchi 63076 Monteprandone AP ITALY Tel 39 0735 705007 _ Fax 39 0735 704912 DCMIINE0A2FD1008E 100 20200525 DRAFT ...

Отзывы: