background image

15

 

IDS 805 User Manual   700-266-01C   Issued March 2009 

 

If the ARMED indicator remains lit, an error was made while entering the user code, press the 

[#] 

key, and re-enter the code. 

 

Once the system disarms, the ARMED indicator will turn off and the keypad buzzer will stop 

sounding. 

 

If no valid user code has been entered by the end of the entry delay period, an alarm condition 

will be registered. 

 

If the entry period is too short, have your installer change the entry delay period. 

 

If four incorrect user codes are entered consecutively while either arming or disarming the 

system, the keypad will be non-responsive for 30 seconds. Your monitoring company will also be 

notified on a keypad tamper. 

 

NOTE: 

If the ARMED indicator is flashing upon entry, there has been a violation. The intruder may still be inside! 

Call for assistance. 

 

NOTE: 

If a strobe (or flashing light) has been installed and an alarm condition is registered, the light will continue 

flashing after the siren has stopped sounding. Entering a valid 

[USER CODE]

 will cancel the strobe. 

 

7.2                         To Disarm with a Key-switch or Remote Control                           

 

1.

 

Press the remote button or twist and release the key-switch. 

2.

 

The system will disarm and the remote indicator (if installed) will turn off. 

3.

 

If programmed to do so, the siren will sound briefly - verify with your installer. 

 

8.                                              Emergency Situations                                                   

 

8.1                                                       Fire Alarm                                                                

 

Hold down the [F] key until the beep 

 

 

If the 

[F]

 key is pressed until the keypad beeps (approximately 1 second) a FIRE ALARM 

condition will be activated. 

 

The FIRE ALARM CONDITION can also be triggered by a smoke detector connected to an 

appropriately programmed zone. 

 

The siren will sound (1 second on, 1 second off) and the FIRE REPORTING CODE will be 

transmitted to the monitoring company. 

 

To silence the siren enter a 4 digit 

[USER CODE].

 The siren will stop sounding after 10 minutes 

if no user code is entered. 

 

8.2                                                      Panic Alarm                                                          

 

Hold down the [P] key until the beep 

 

 

If the

 

[P]

 key is pressed until the keypad beeps (approximately 1 second) a PANIC ALARM 

condition will be activated. 

 

Any FIXED PANIC or REMOTE PANIC buttons which may have been installed can also activate a 

PANIC ALARM. 

 

If audible panic option has been selected, the siren will sound. A PANIC REPORTING CODE will 

be transmitted to the monitoring company. 

 

To silence the siren, enter a valid 4 digit 

[USER CODE].

 If the siren is not cancelled, it will stop 

Содержание IDS 805

Страница 1: ......

Страница 2: ...2 IDS 805 User Manual 700 266 01C Issued March 2009...

Страница 3: ...13 5 6 Arming from a Key switch or Remote Control 13 5 7 Auto Arming 13 5 8 Arming with Entry Exit or Follower Zones Violated 13 5 9 Forced Arming 14 6 Zone Bypassing 14 6 1 To Bypass a Zone 14 6 2 To...

Страница 4: ...3 Buzz Zones 19 13 1 To Program Buzz Zones 19 13 2 ToCancel Buzz Zones 20 14 Chime Zones 20 14 1 To Program the Chime Zones 20 14 2 To Cancel the Chime Zones 20 15 Troubleshooting 21 15 1 Trouble Cond...

Страница 5: ...5 IDS 805 User Manual 700 266 01C Issued March 2009...

Страница 6: ...6 IDS 805 User Manual 700 266 01C Issued March 2009...

Страница 7: ...to the keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home Follower Zone A zone that may be temp...

Страница 8: ...and serviced by a qualified security professional who should instruct you regarding the level of protection provided and the operation of the system Should you have any questions regarding the operati...

Страница 9: ...unted in a convenient location within the protected premises generally close to the Entry Exit zones After a preprogrammed period of inactivity the keypad will automatically enter into a power save mo...

Страница 10: ...lated Stay Arm Stay Arm and Go Forced Arming Push to Arm Siren Sound on Arm Disarm single toot arm double2 toot disarm Panic Alarm Fire Alarm Chime Zones Buzz Zones Zone Tamper Monitoring Arm with Key...

Страница 11: ...nt door 3 Press the key to cancel any unintended key entries 4 Enter a valid 4 digit USER CODE If you make a mistake press the key and re enter the code 5 The ARMED indicator will come on and the keyp...

Страница 12: ...is selected the system will use the selected profile each time the system is armed into the STAY MODE If the alternate profile is required it is necessary to select the alternate profile before the s...

Страница 13: ...or Remote Control Single toot on Arm Double toot on Disarm 1 Ensure that the READY indicator is on before leaving 2 Leave and close the door remembering to lock 3 Press the remote button or twist and...

Страница 14: ...the key while bypassing zones violated zones will be flashing 2 Press the number corresponding to the zone you need to bypass e g the 2 key if you wish to bypass zone 2 3 The relevant zone indicator w...

Страница 15: ...te Control 1 Press the remote button or twist and release the key switch 2 The system will disarm and the remote indicator if installed will turn off 3 If programmed to do so the siren will sound brie...

Страница 16: ...is advisable to choose a code that can be easily remembered by all family or staff members 9 Emergency Evacuation Plan An emergency evacuation plan should be established in case of a fire Draw up a fl...

Страница 17: ...s occurred To Display Zone Tamper Memory 0 then 2 1 Hold down 0 until the keypad buzzer sounds 2 The READY indicator will turn off and the keypad buzzer will sound briefly 3 Flashing zone indicators s...

Страница 18: ...Monday arming the system on a Monday morning using the maid s code will allow the maid to disarm the system On days that any other user code i e not a maid s code has been used to arm the system enter...

Страница 19: ...cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alar...

Страница 20: ...ers or exits the front door the keypad will beep each time the door is opened if that zone is programmed as a chime zone 14 1 To Program the Chime Zones 2 ZONE NUMBER 1 Hold down the 2 key until the k...

Страница 21: ...ress within 5 seconds of viewing To simply cancel the beeping without viewing the trouble conditions press Indicator Trouble Condition 2 Failure to communicate to monitoring company 3 Mains power fail...

Страница 22: ...e strayed into an Instant zone Does the siren sound before you get to the keypad You have strayed into a non follower zone OR You have taken too long to get to the keypad The panel will not disarm You...

Страница 23: ...g13 B Battery 8 21 Buzz Zone 10 12 18 19 20 Bypass 7 9 11 12 13 14 16 17 18 21 27 C Control Panel 8 16 Chime 8 9 10 20 27 D Disarm 7 8 10 13 14 15 16 18 20 22 27 Duress 10 16 17 27 E Emergency Evacuat...

Страница 24: ...see Arm Quick Stay Arm Go see Arm R Remote Control see Key switch Reporting Code 7 S Siren 10 13 15 16 20 21 22 Stay Arm see Arm Stay Arm Go see Arm Stay Mode 8 12 18 Stay Profile 12 27 Strobe 15 T Ta...

Страница 25: ...25 IDS 805 User Manual 700 266 01C Issued March 2009...

Страница 26: ...26 IDS 805 User Manual 700 266 01C Issued March 2009...

Страница 27: ...ld down P for 1 second Fire Hold down F for 1 second Medical Emergency Hold down M for 1 second Alarm Memory Hold down 0 for 1 second Change Stay Profile MODE 9 PROFILE NUMBER Bypass a zone ZONE NUMBE...

Страница 28: ...28 IDS 805 User Manual 700 266 01C Issued March 2009...

Отзывы: