Technical manual MA xxxx with ATS MAxx
51
©INGUN: Subject to technical changes without notice. E&OE.
10.1.6 Inductive sensor (Part number 44833)
Type: inductive sensor
Switching status display: LED yellow
Start switching status: PNP closing
contact (NO)
Switching frequency: 2 kHz
Nominal voltage: 10 - 30 VDC
Current consumption max.: <15 mA
Output current: 100 mA
Protection category: IP 65
Working temperature: -25 - +75 °C
Nominal switching distance: 1,2 mm
Connection
10.1.7 Stroke magnet NC (currentless; closed) (Part number 50856)
Nominal voltage: 24 VDC
Power consumption: 7,2 Watt
Switching duration: 100 %
For reduced continuous operation
(see 2.1.4, p. 7)
Recommended series resistor : 47 Ohm /
≥10 W
Connection
(polarity optional)
10.1.8 Stroke magnet NO (currentless; open) (Part number 33491)
Nominal voltage: 24 VDC
Power consumption: 8 Watt (300 mA)
Switching duration: 100 %
For reduced continuous operation
Recommended series resistor : 75 Ohm /
≥10 W
Connection
(polarity optional)
10.1.9 Valve assembly 3/2-way (Part number 43583)
Part number valve: 41752
Part number cable: 36547
Valve operation: 3/2 closed,
mono-stable
Operating air pressure: 0.9
– 10 bar
Pneumatic connection: M5
Return type: Mixed, pneumatic/
mechanical
Ambient and medium temperature: -5 - 50 °C
Nominal voltage: 24 VDC
Power: 1 W
Display: LED
Function chart
10.1.10 Valve assembly 5/2-way (Part number 42702)
Part no. valve: 36541
Part no. cable: 36547
Valve operation: 5/2 Control Valve,
mono-stable
Operating air pressure: 0.9
– 10 bar
Pneumatic connection: M5
Return type: Mixed, pneumatic/
mechanical
Ambient and medium temperature: -5 - 50 °C
Nominal voltage: 24 VDC
Power: 1 W
Display: LED
Function chart
Содержание MA 2x09 Series
Страница 1: ...Technical manual Manual Test Fixture MA xxxx with ATS MAxx...
Страница 55: ...Technical manual MA xxxx with ATS MAxx INGUN Subject to technical changes without notice E OE 54...
Страница 57: ...Technical manual MA xxxx with ATS MAxx INGUN Subject to technical changes without notice E OE 56...
Страница 58: ...Technical manual MA xxxx with ATS MAxx 57 INGUN Subject to technical changes without notice E OE...