2.7. Specifications tables
2.8TL U M
3.3TL U M
5TL U M
6TL U M
DC inputs
Recommended power range of PV array
(1)
2.8 ~ 3.3 kWp
3.4 ~ 4.3 kWp
5.1 ~ 6.5 kWp
6.1 ~ 7.8 kWp
Maximum input voltage
(2)
850 V
850 V
850 V
850 V
Voltage range MPP1
(3)
125 ~ 750 V
125 ~ 750 V
125 ~ 750 V
125 ~ 750 V
Voltage range MPP2
(3) (4)
90 ~ 750 V
90 ~ 750 V
90 ~ 750 V
90 ~ 750 V
Operating voltage range
(4)
90/125 ~ 850 V
90/125 ~ 850 V
90/125 ~ 850 V
90/125 ~ 850 V
Minimum voltage for Pnom with DC inputs
in parallel
127 V
150 V
227 V
273 V
Maximum short circuit current
(input 1 / input 2)
13 / 13 A
13 / 13 A
13 / 13 A
13 / 13 A
Maximum inverter backfeed current to the
array
0 A rms
0 A rms
0 A rms
0 A rms
MPPT
2
2
2
2
Number of strings
2
2
2
2
Strings per MPP
1
1
1
1
Maximum input current
(input 1 / input 2)
11 / 11 A
11 / 11 A
11 / 11 A
11 / 11 A
Maximum input current per string
11 A
11 A
11 A
11 A
AC output
Nominal power (up to 113 ºF, 45 ºC)
2.8 kW
3.3 kW
5 kW
6 kW
Maximum continuous power
2.8 kW
3.3 kW
5 kW
6 kW
Max. temperature for nominal power
(5)
113 ºF (45 ºC)
113 ºF (45 ºC)
113 ºF (45 ºC)
113 ºF (45 ºC)
Maximum current
16 A
16 A
26.2 A
26.2 A
Maximum transient current
16 A
16 A
26.2 A
26.2 A
Maximum output fault current
216 A @ 1.7 ms
216 A @ 1.7 ms
216 A @ 1.7 ms
216 A @ 1.7 ms
Maximum output overcurrent protection
18 A rms
18 A rms
30 A rms
30 A rms
Rated voltage
208/240 V
208/240 V
208/240 V
240 V
Voltage range
88 ~ 110 % Vnom
88 ~ 110 % Vnom
88 ~ 110 % Vnom
88 ~ 110 % Vnom
Nominal frequency
60 Hz
60 Hz
60 Hz
60 Hz
Cosine of Phi
1
1
1
1
Adjustable cosine of phi
Yes. Smax = 2.8 kVA
Yes. Smax = 3.3 kVA
Yes. Smax = 5 kVA
Yes. Smax = 6 kVA
THD
< 3 %
< 3 %
< 3 %
< 3 %
Performance
Maximum efficiency
98.6 % (240 Vac)
98.2 % (208 Vac)
98.5 % (240 Vac)
98.4 % (208 Vac)
98.4 % (240 Vac)
98.2 % (208 Vac)
98.9 % (240 Vac)
CEC
97.0 % (240 Vac)
97.0 % (208 Vac)
97.5 % (240 Vac)
97.5 % (208 Vac)
97.5 % (240 Vac)
97.5 % (208 Vac)
98.0 % (240 Vac)
General data
Cooling system
Natural convection
Forced ventilation
Air flow
-
0.44 ft
3
/s (45 m
3
/h)
Weight
44.1 lb (20 Kg)
46.3 lb (21 Kg)
Measurements (height x width x depth)
18.5 x 14.17 x 7.09 in (470 x 360 x 180 mm)
Standby current
(6)
< 10 W
< 10 W
< 10 W
< 10 W
Night consumption
0 W
0 W
0 W
0 W
Operating temperature
-13 ºF ~ 149 ºF (-25 ºC ~ 65 ºC)
Relative humidity (without condensation)
0 ~ 100 %
0 ~ 100 %
0 ~ 100 %
0 ~ 100 %
Protection class
NEMA 4
NEMA 4
NEMA 4
NEMA 4
Markings
CE, ETL
EMC and safety regulations
UL1741, FCC Part 15, IEEE C37.90.1, IEEE C37.90.2
Grid connection regulations
IEC 62116, UL1741, IEEE1547, IEEE1547.1, NEC CODE
(1)
Depending on the type of installation and the geographic location.
(2)
Never exceed this value. Consider the voltage increase of the panels ‘Voc’ at low
temperatures.
(3)
The output power will be determined by the voltage and current configuration selected at each input.
(4)
To lower it to 90 V the other
input must be at 125 V at least.
(5)
For each ºF of increase, the output power is reduced by 1.8 %.
(6)
Consumption from the PV array.
13
Unit description
Ingeteam
EN
ES
ABE2013IQM01_ - Installation and Operation Manual
Содержание INGECON SUN 1Play 2.8TL U M
Страница 1: ...INGECON SUN 1Play TL M U Installation and Operation Manual Manual de instalaci n y uso...
Страница 3: ...iii Ingeteam English EN Espa ol ES...
Страница 81: ...Notes Notas...
Страница 82: ...Notes Notas...
Страница 84: ...Ingeteam Power Technology S A www ingeteam com ABE2013IQM01_ 04 2015...