Z-WAVE CONFIGURATION TABLE

Parameter Description

Length 

(Bytes) R/W

Default 

Value

Valid Values

1

Time between Battery Reports (hours)

1

R/W

0

0 = Do not send periodically; Range: 1–127 hours

2

Send BASIC SET ON above this temperature (See #20)

1

R/W

121

121 = Disabled; Range: 15 – 120° F

3

Send BASIC SET ON below this temperature (See #20)

1

R/W

121

121 = Disabled; Range: 15 – 120° F

4

Send BASIC SET OFF above this temperature (See #20)

1

R/W

121

121 = Disabled; Range: 15 – 120° F

5

Send BASIC SET OFF below this temperature (See #20)

1

R/W

121

121 = Disabled; Range: 15 – 120° F

6

Send multiple attempts for all BASIC SET commands

1

R/W

0

0 = Disabled; 1-5 = Number of extra attempts sent every 

minute after first send

7

Temperature Units

1

R/W

1

0 = Celsius; 1 = Fahrenheit

8

Association Group1 – Temperature delta auto send threshold

1

R/W

10

Range: 1 – 200; Parameter is in tenths of degrees. 

9

Association Group1 – Periodic temperature send interval 

1

R/W

0

0 = Disabled; Range: 1-120 minutes

10

Association Group2 – Temperature delta auto send threshold 

1

R/W

10

0 = Disabled; Range: 1 – 50; Parameter is in tenths of 

degrees.

11

Association Group2 – Periodic temperature send interval 

1

R/W

0

0 = Disabled; Range: 1-120 minutes

12

Send BASIC SET ON above this humidity (See #20) 

1

R/W

0

0 = Disabled; Range: 1–100%

13

Send BASIC SET ON below this  humidity  (See #20)

1

R/W

0

0 = Disabled; Range: 1-100%

14

Send BASIC SET OFF above this  humidity  (See #20)

1

R/W

0

0 = Disabled; Range: 1-100%

15

Send BASIC SET OFF below this  humidity  (See #20)

1

R/W

0

0 = Disabled; Range: 1-100%

16

Association Group1 – Humidity delta auto send threshold

1

R/W

5

Range: 1-50%

17

Association Group1 – Periodic humidity send interval

1

R/W

0

0 = Disabled; Range: 1-120 minutes

18

Association Group3 – Humidity delta auto send threshold

1

R/W

5

0 = Disabled; Range: 1-30%

19

Association Group3 – Periodic humidity send interval

1

R/W

0

0 = Disabled Range: 1-120 minutes

20

BASIC SET options for temperature and humidity

1

R/W

1

Configuration Register Combinations: 

1 = Enable Registers 2, 5, 12 15 

2 = Enable Registers 2, 5, 13, 14 

3 = Enable Registers 3, 4, 12, 15 

4 = Enable Registers 3, 4, 13, 14

21

Temperature Offset

1

R/W

0

Range: -7 to 7° F

22

Humidity Offset

1

R/W

0

Range: -7% to 7%

23

Humidity Filter Time Constant

1

R/W

30

Range: 1 – 60 minutes

ASSOCIATION GROUP INFORMATION TABLE

GROUP

PROFILE

COMMAND CLASSES

GROUP NAME

MAX DEVICES

1

Lifeline

Battery Report, Multilevel Sensor Report, Device Reset 

Locally Notification

Lifeline

1

2

Sensor

Multilevel Sensor Report

Temperature Reports

5

3

Sensor

Multilevel Sensor Report

Humidity Reports

5

4

Sensor

Basic Set

Temperature Driven Basic Sets

5

5

Sensor

Basic Set

Humidity Driven Basic Sets

5

6

Sensor

Battery Report

Battery Reports

5

FCC STATEMENT
This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and (2) This device 

must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for Class 

B Digital Device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  

This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 

communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.

•  Reorient or relocate the receiving antenna

•  Increase the separation between the equipment and receiver

•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

•  Consult the dealer or an experienced radio/TV technician for help

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) 

this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) 

l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’encompromettre le  

fonctionnement.

© 2018 Ingersoll Rand
18-HD85D1-1 Rev. 20180723

Nexiahome.com

U.S.A. / Canada 

(877) 288-7707

*

* Configurable through third party Z-Wave systems.

Содержание ZSENS930AW00MA

Страница 1: ...TEP 4 Put the Z Wave bridge in Add mode Press the or Add button on the bridge STEP 5 Add the sensor Stand where the sensor is to be installed and press and release the button labeled INSTALL on the interior of the sensor STEP 6 Connection Status The status LED next to the button on the interior of the sensor will blink rapidly for 3 seconds when it has been added to your Z Wave network STEP 7 Moun...

Страница 2: ...r is now assigned The list of assigned and averaged sensors on the left is now updated and the previously unassigned sensor is now included Screen 2 Screen 2 STEP 5 4 Press Done The Done button saves and exits the Indoor Sensor Setup screen Tap Done if finnished After this step follow Step 7 and 8 from Page 1 if not already complete NOTE By default all sensors in the Assigned list are averaged tog...

Страница 3: ... dimmer at a location between the bridge and sensor Button press ignored Button press too fast or too slow Firm 1 2 second button press Sensor goes from Online to Offline and Missing Sensor alarm TSO 001 00 is shown Sensor is enabled but offline not reporting Change the batteries in the sensor Remove the offline sensor following the steps from Table 3 then reinstall or add a new sensor Add a signa...

Страница 4: ...lly Notification Lifeline 1 2 Sensor Multilevel Sensor Report Temperature Reports 5 3 Sensor Multilevel Sensor Report Humidity Reports 5 4 Sensor Basic Set Temperature Driven Basic Sets 5 5 Sensor Basic Set Humidity Driven Basic Sets 5 6 Sensor Battery Report Battery Reports 5 FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 Th...

Отзывы: