The keypad can be programmed prior to installation.
Programmed information is stored in nonvolatile
memory so it will not be lost when power is removed.
To Enter Programming Mode: Press 9-9-# and
the master code
Factory set at
1-2-3-4, followed
by the *·
Note: You must press * after entering any code
number. Many commands dealing with user codes
require the code to be entered twice during the
programming sequence for verification purposes. The
keypad will automatically log out of programming
mode after 30 seconds without a key entry.
The keypad is now in programming mode, and
the yellow light will flash slowly. The unit is
preprogrammed with a factory code of 1234. This
code is removed when you program a master code
(See command 50). If the master code is forgotten,
remove and replace jumper J1 when power is
applied to force the keypad into programming mode.
To Exit Programming Mode: Press *· The yellow
LED will stop flashing.
Note: If a programming error occurs, indicated by a
solid yellow LED, simply press *· The yellow LED
should start flashing again. Re-enter command.
Command
46
50
50
50
52
70
99
Function
Erase complete memory.
Erases the master code. After executing this
command, go to command 50 and define a new
master code. If keypad logs out of programming
mode before you define a master code, briefly
remove jumper J1 to access programming.
Change master code.
The code in user position 1 actuates the unlock relay
and also accesses programming mode. See
command
99.
Default: factory code = 1234.
Add user.
These codes will unlock door. In addition, the codes
in user positions 2 and 3 will clear the keypad
lockout prior to its timeout.
Delete user, duress user, lockout user.
Erases code in user positions 2 to 100.
Add user lockout location.
These codes disable users in higher numbered user
positions until the user lockout code is entered again
(toggle ON/OFF). User lockout codes will not unlock
door.
Set keypad lockout count.
Multiple incorrect code entries will not allow a user to
unlock the door for 30 seconds. Indicated by a solid
yellow LED. The master and supervisor codes (users
1, 2, and 3) clear the keypad for use. Default =3
wrong entries.
Enter programming mode.
Default= master code is 1234.
Code Entry
46#00000#00000#**
50#T#1#Code*Code*
T=O to 90 seconds (O =toggle)
Code =2 to 6 digit number
SO#T#U#Code*Code*
T =O for toggle or 3 for master time
U =user position
2
to 100
Code =2 to
6
digit number
SO#O#U#**
U= user position 2 to 100
52#0#U#Code*Code*
U= user position 2 to 100
Code =2 to
6
digit number
70#0#N#**
N=3 to 25 wrong entries
99#Master*
Master = master code
(see command #SO)