ColdCube Operation
30
ColdCube is
working but not
cooling down
Lack of refrigerant
gas
Check for
refrigerant gas
leakage and
vacuum /
recharge the unit
gas quantity on
the serial
number label.
Oil in the circuit
(probably the
ColdCube has
operated for some
time with a high
angle)
Repeat short
operation cycles
(few minutes on
and then 5
minutes off) to let
the oil turn back
to compressor. If
not solved then
vacuum and
recharge.
Compressor
defective
Replace
compressor
Problem
Possible Reason
Action