ColdCube Remote Display Option
20
Figure 6: Tighten Bulkhead
4.
Connect wires together up to front of vehicle and to the
Remote Display.
5.
Use the following procedure to modify one parameter of
the controller to allow transmission of data to the Remote
Display:
a.
With the ColdCube
ON
, press
PRG
and
SET
buttons
together for more than 5 seconds. The display will
show the number “
0
”, representing the password
prompt.
b.
Press "
" or "
" until the number “
22
” (the
code of the password that allows access to the
parameters) is displayed.
c.
Confirm by pressing
SET
. The display will show the
code of the first modifiable type “
C
” parameter (“
/2
”)
d.
Press "
" or "
" until reaching the parameter
“
/te
”.
e.
Press
SET
to display the value associated with the
parameter: should be “
0
”. Change to “
1
” using the
"
" or "
"buttons.
f.
Press
SET
to temporarily save the new value and
return to the display of the parameter code.
g.
To store the new values of the modified parameters,
press
PRG
for more than 5 seconds to exit the
parameter setting procedure.