INSTALLATION / HANDLING
35
SL, SM & SH 90, 110, 132, 150, 200, 250 &300 (50Hz)
L, H & HH 125, 150, 200, 250, 300, 350 & 400 (60Hz)
Sheet 3
Revision A
85549756
200–300kW
AC 50Hz
Notes:
1. Weights approximate:
200kW IP23 9200 lbs (4173 kg)
250/300kW IP23 9600 lbs (4354 kg)
200/250kW IP55 10700 lbs (4853 kg)
300kW IP55 11300 lbs (5126 kg)
2. Cooling air flow: 566 m
3
/min – 20000 CFM.
3. Pipe condensate drain lines separately to an open drain due to
difference in drain pressures.
4. Lube oil fill quantity: 91 litres (24 gallons) approximately.
5. All dimensions in inches (millimeters).
6. Tolerance on all dimensions:
±
6 mm (
±
.25 inch).
7. Recommended clearance on three sides 914 (36.00). 1067 (42.00)
front of control panel or minimum as required by latest national
electrical code or applicable local codes.
8. External piping shall not exert any unresolved moments or forces
on unit. Use pipe size as large or larger at discharge location.
9. There should be no plastic or PVC piping attached to this unit or
used for any lines downstream.
10.Forklift hole covers must be installed after unit is in place to reduce
noise and insure proper cooling of package.
11. Field installed ducting to and from compressor cannot add more
than 6mm (0.25 inches) of water total air resistance. Gear box breather
must be piped external.
12.Unit has internal discharge check valve. External check valve not
required. Isolation valve is recommended.
13.Compressor should be bolted to the floor with four 19mm (0.75)
bolts located as shown on sheet 2 in the bottom view with it being
sealed with cork or rubber.
14.Do not pipe into a common header with a reciprocating compressor,
unless reciprocating compressor utilizes a discharge pulsation
dampener.
15.
Denotes center of gravity.
16.Sizing of electrical components not supplied by Ingersoll–Rand is
the responsibility of the customer and should be done in accordance
with the information on the compressor data plate. National and local
electrical codes.
17.Electrical power inlet connection to be cut by customer inside of
starter box indicated. Exact size and positioning to be determined by
the customer in accordance with note 16.
18.When installed indoors or under a shelter, the cooling air inlet or
exhaust must be ducted away from the unit to prevent recirculation of
hot exhaust air.